Siemens SIMOVERT MASTERDRIVES 6SE7090-0XX84-0AB0 CUVC Vector Control Unit
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Hot Selling Models
- Producta commendata
Conspectus
- Use only in a converter platform designed for the SIMOVERT MASTERDRIVES CUVC control unit.
- Back up and compare the complete drive parameter set before removing the existing board.
- Map CU2 wiring to the CUVC terminal designations instead of transferring conductors by terminal number.
- Check all X101 digital and RS485 functions against the installed circuit.
- Set the X102 switches and parameters for the actual voltage or current signal ranges.
- Confirm encoder signal type, track assignment and the 15 V 150 mA supply limit.
- Select PTC or KTY84 evaluation to match the connected motor sensor.
- Addere EB2 solummodo cum outputa flottantia vel contactus commutatoris rellae requiruntur.
- Restituere attributiones BICO et verificare utrasque series dati antequam impellere ad servitium redigitur.
Siemens · SIMOVERT MASTERDRIVES Vector Control
6SE7090-0XX84-0AB0 CUVC Control Unit Vector Control
Siemens 6SE7090-0XX84-0AB0 is the CUVC Control Unit Vector Control for the SIMOVERT MASTERDRIVES product family. It combines drive-control processing with digital and analog control terminals, serial communication, HTL pulse-encoder feedback and motor-temperature evaluation. The control unit is used as the central control board in a compatible MASTERDRIVES converter. Replacement requires preservation of the drive parameter set and verification of the X101, X102 and X103 terminal allocation because CUVC signal assignments differ from earlier CU2 hardware.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SE7090-0XX84-0AB0 |
| Typus Producti | Vector Control Unit |
| Functio principalis | Executes open-loop and closed-loop vector control for a SIMOVERT MASTERDRIVES converter |
| Applicatio vel series compatibiles | SIMOVERT MASTERDRIVES Vector Control drive systems |
Exact Control Board
Match the complete 0AB0 article number and the CUVC Vector Control function before exchanging the board.
Terminal Migration
Record X101, X102 and X103 wiring because CU2 and CUVC terminals are not a position-for-position match.
Parameter Recovery
Back up the drive parameter set and verify BICO, analog-range, encoder and temperature-sensor settings before removal.
Product Overview
Siemens 6SE7090-0XX84-0AB0 is the CUVC Control Unit Vector Control for the SIMOVERT MASTERDRIVES product family. It combines drive-control processing with digital and analog control terminals, serial communication, HTL pulse-encoder feedback and motor-temperature evaluation. The control unit is used as the central control board in a compatible MASTERDRIVES converter. Replacement requires preservation of the drive parameter set and verification of the X101, X102 and X103 terminal allocation because CUVC signal assignments differ from earlier CU2 hardware.
Provides the central open-loop and closed-loop control functions for compatible MASTERDRIVES Vector Control converters. Handles digital I/O, two analog input channels, two analog output channels and serial communication on the base board. Accepts unipolar HTL pulse-encoder signals and either PTC or KTY84 motor-temperature feedback.
Key Functions
Vector Drive Control
Provides the central open-loop and closed-loop control functions for compatible MASTERDRIVES Vector Control converters.
Integrated Signal Interfaces
Handles digital I/O, two analog input channels, two analog output channels and serial communication on the base board.
Motor Feedback Processing
Accepts unipolar HTL pulse-encoder signals and either PTC or KTY84 motor-temperature feedback.
Official Specifications
| Service Communication | RS232 or RS485 serial interface for a PC or OP1S operator panel |
|---|---|
| Interfaccia USS | Second serial interface on X101 using two-wire RS485; four-wire USS is not supported |
| Hulp 24 V Uitgang | 24 V DC, maximum 150 mA ad terminales X101 1 et 2 |
| Canalia Digitalia Bidirectionalia | DIO1 ad DIO4 ad terminales X101 3 ad 6 |
| Ingressus Digitales Specializati | DI5 ad DI7 ad terminales X101 7 ad 9 |
| Characteristicum Egressus Digitalis | Compatibile cum SIMATIC; egressus digitales flottantes requirunt tabulam extensionis EB2 |
| Supplicationes Analogicae de Referentia | +10 V et -10 V, 5 mA utrumque ad terminales X102 13 et 14 |
| Quantitas Ingressus Analogici | 2 canales en los terminales X102 15/16 y 17/18 |
| Intervalla Ingressus Analogi | Seleccionable ±10 V o ±20 mA |
| Evaluación de entrada analógica | Bipolar, unipolar o 4 a 20 mA |
| Diagnóstico de bucle de corriente | La supervisión de rotura de cable puede activarse para la evaluación de 4 a 20 mA |
| Cantidad de salida analógica | 2 canales en los terminales X102 19/20 y 21/22 |
| Limites Egressus Analogici | Seleccionable ±10 V o 0 a 20 mA |
| Interfacs Encoder | Codificador de pulsos HTL unipolar con pista A, pista B, pista cero y señal de supervisión en X103 |
| Alimentatio encoderis | 15 V DC, maximum 150 mA at X103 terminal 28 |
| Motor Temperature Sensor | PTC or KTY84 input on X103 terminals 29 and 30 |
| BICO Data Sets | 2 selectable BICO data sets |
| Floating Changeover Output | Requires an EB2 extension board |
Quaestiones Frequenter Rogatae
Can 6SE7090-0XX84-0AB0 use the same terminal positions as an older CU2 board?
No, the CU2-to-CUVC conversion requires terminal reassignment and a parameter review rather than position-for-position rewiring.
Quod encoder ad 6SE7090-0XX84-0AB0 coniungere possum?
Usurpa unipolare HTL pulse encoder cum signis A, B, zero et monitoring, et intra limites 15 V 150 mA manebis.
Quae analogarum input intervalla in 6SE7090-0XX84-0AB0 disponibilia sunt?
Unumquodque analogum input commutari potest pro ±10 V aut ±20 mA, et utroque modo bipolariter, unipolariter, aut ut 4 ad 20 mA aestimari potest.
Num 6SE7090-0XX84-0AB0 ruptam 4 ad 20 mA input circuitum detegere potest?
Ita, wire-break monitoring activari potest, dum canalis pro 4 ad 20 mA evaluatione configuratur.
Quae motoris temperaturae sensoria cum 6SE7090-0XX84-0AB0 operantur?
Motoris-temperaturae input accipit vel PTC vel KTY84 sensorem, cum correspondente parametri positione.
Num 6SE7090-0XX84-0AB0 quattuor-filarem USS communicationem supportat?
Non, onboard USS interface duobus filis RS485 utitur et quattuor-filarem USS non supportat.
When does 6SE7090-0XX84-0AB0 require an EB2 extension board?
Use an EB2 when the application needs floating digital outputs or a floating relay changeover contact.