- Overview
- Hot Selling Models
- Recommended Products
Overview
- Select the SML2 lower-unit assembly for the compatible installed power section.
- Disconnect the equipment from its supply and observe the minimum five-minute DC-link discharge delay before work.
- Have qualified personnel remove the capacitor battery before accessing the snubber assembly.
- Preserve the mechanical arrangement and reinstall the replacement in reverse disassembly order.
6SE7033-7EH84-1GG0 MASTERDRIVES SML2 Lower Snubber Module
The Siemens SML2 lower snubber module for a compatible SIMOVERT MASTERDRIVES inverter power assembly, with a net mass of 0.2 kg.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SE7033-7EH84-1GG0 |
| Product Type | Inverter wiring board |
| Core Function | Provide an internal power-section connection |
| Application | Compatible MASTERDRIVES converter assemblies |
Lower snubber position
SML denotes the lower snubber assembly, while SMU denotes the separate upper snubber assembly.
Internal inverter spare
The board is a power-section spare for a compatible MASTERDRIVES converter assembly rather than a complete frequency inverter.
Service access sequence
The capacitor battery is removed before releasing the snubber module, and the replacement is installed in reverse order.
Product Overview
6SE7033-7EH84-1GG0 is the SML2 inverter wiring board identified as the lower-unit snubber module in the MASTERDRIVES power assembly.
Service access to the lower snubber assembly follows removal of the capacitor battery, with installation carried out in the reverse order of disassembly.
Key Functions
Lower snubber position
SML denotes the lower snubber assembly, while SMU denotes the separate upper snubber assembly.
Internal inverter spare
The board is a power-section spare for a compatible MASTERDRIVES converter assembly rather than a complete frequency inverter.
Service access sequence
The capacitor battery is removed before releasing the snubber module, and the replacement is installed in reverse order.
Official Specifications
| Assembly designation | SML2 |
|---|---|
| Installation position | Lower unit |
| Net mass | 0.2 kg |
| UPC | 662643065435 |
| Commodity Code | 85049090 |
| RoHS Substance Restrictions | Not RoHS-compliant |
| Siemens WEEE Take-Back Obligations (2012/19/EU) | No manufacturer take-back obligation |
| Dangerous Goods Classification | Not classified as dangerous goods |
Frequently Asked Questions
Can I order 6SE7033-7EH84-1GG0 as a complete frequency inverter?
This article is an internal SML2 wiring and snubber assembly rather than a complete converter.
Is 6SE7033-7EH84-1GG0 the upper or the lower snubber module?
It is the lower snubber module, while the upper assembly is designated SMU.
What must be removed to access 6SE7033-7EH84-1GG0 in the power assembly?
Remove the capacitor battery before releasing the snubber module.
Can I begin work on 6SE7033-7EH84-1GG0 immediately after disconnecting converter power?
Wait at least five minutes after disconnecting the power supply before working on the converter or DC-link terminals.
Who should carry out replacement of 6SE7033-7EH84-1GG0?
Maintenance and service work on the MASTERDRIVES power assembly must be performed by qualified personnel.
How is the replacement sequence completed for 6SE7033-7EH84-1GG0?
Install the replacement snubber assembly in the reverse sequence of removal.
How much spare-part mass should I allow for 6SE7033-7EH84-1GG0?
The net mass of the module is 0.2 kg.