Overview
SIMATIC RF / MV

6GT2891-4JH50 SIMATIC RF RS422 M12 Reader Cable 5 m

Five-metre flexible RS422 reader cable with straight M12 male and angled M12 female connectors, a black PUR sheath and shielding for industrial movement.

At a Glance

Brand Siemens
Model 6GT2891-4JH50
Product Type Preassembled reader connection cable
Core Function RS422 connection between communication module and reader
Application SIMATIC RF and MV identification systems

Ready-made RS422 link

The assembled M12 cable connects a reader to a compatible SIMATIC communication module.

Flexible routing

Specified repeated and continuous bend limits support moving installation design.

Industrial cable construction

The shielded cable uses a PUR outer sheath resistant to mineral oil, grease and UV exposure.

Product Overview

6GT2891-4JH50 is a preassembled SIMATIC RF/MV communication cable for connecting a compatible reader to a communication module. The cable has an angled reader connector and is listed for ASM 456, RF160C, RF170C, RF18XC and RF182C applications.

Its six-core construction combines PVC conductor insulation, a tin-plated copper braid and a black PUR outer sheath. Separate bend radii apply to a single bend, repeated bends and continuous movement, allowing routing to match the actual mechanical duty.

Ordering focus: Match the module and reader pin assignments, straight/angled M12 connector orientation and five-metre route, then select the bend radius for the movement duty.
Key Functions

Ready-made RS422 link

The assembled M12 cable connects a reader to a compatible SIMATIC communication module.

Flexible routing

Specified repeated and continuous bend limits support moving installation design.

Industrial cable construction

The shielded cable uses a PUR outer sheath resistant to mineral oil, grease and UV exposure.

Official Specifications
Cable length 5 m
Connector arrangement M12 male, 8-pin, straight / M12 female, 8-pin, angled
Cable designation L-YC11Y 6x1x0.25 6x24AWG CM
Number of cores 6
Shield Tin-plated copper-wire braid
Insulation and sheath PVC conductor insulation; black PUR sheath
Outer diameter 5.4 mm ±0.2 mm
Minimum single-bend radius 21.6 mm
Minimum repeated-bend radius 43 mm
Continuous-bending radius 75 mm
Bending cycles 3,000,000
Maximum tensile load 200 N
Maximum loop resistance 160 mΩ/m
Insulation resistance coefficient 20 GΩ·m
Weight per length 45 kg/km
Temperature range −30 to +80 °C during operation, storage, transport and installation
Fire performance Flame resistant to IEC 60332-1-2; class Eca to EN 13501-6
Environmental resistance Resistant to mineral oil, grease and UV radiation
Material features Silicone-free; not halogen-free
Frequently Asked Questions

Which end of 6GT2891-4JH50 has the angled connector?

The reader end has an angled 8-pin M12 female connector, while the opposite end is a straight 8-pin M12 male connector.

Which communication modules are listed for 6GT2891-4JH50?

Compatible communication modules include ASM 456, RF160C, RF170C, RF18XC and RF182C when used with the matching reader.

What minimum radius applies to continuous movement of 6GT2891-4JH50?

Use the specified 75 mm continuous-bending radius.

Is the 21.6 mm bend radius of 6GT2891-4JH50 suitable for repeated movement?

That figure applies to a single bend; repeated bends require at least 43 mm and continuous bending requires 75 mm.

How many bending cycles are specified for 6GT2891-4JH50?

The specified bending endurance is 3,000,000 cycles.

Is 6GT2891-4JH50 a halogen-free cable?

No; the cable is silicone-free but contains halogens.

Does the UL/ETL CM 300 V statement cover the connectors of 6GT2891-4JH50?

No; the UL/ETL CM 300 V listing applies only to the cable without the plugs.

Compatibility & Ordering Notes
Before ordering 6GT2891-4JH50: Match the module and reader pin assignments, straight/angled M12 connector orientation and five-metre route, then select the bend radius for the movement duty.

Before installation

  • Verify the reader and communication-module assignments before connecting the preassembled cable.
  • Allow space for the angled reader connector and avoid tensile loads above the 200 N maximum.
  • Use the correct radius for static, repeated or continuous bending rather than applying the single-bend limit to every route.
  • Keep the route within the stated temperature range and assess the cable and connector requirements separately.
Hot Selling Models
IFL15-300-01yG
VAA-4E4A-KE5-ZEJQ/R-KRO
Multi9 C60
1360.9915114
BC20-Q20-AP4X2-H1141
6ES7138-4FA00-0AB0
3RT1035-1AP04 3RH1921-1HA22
3RV2021-1JA15
MCL128N MCLbs128N
BAU5SLX2 85x110x12
ADVUL-25-50-PA
NZ2RL-538L060
PP-H 6/1-R 3061729
55.34.8.024.0050
78 - 02

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.