Siemens 6GT2891-4JH50 SIMATIC RF RS422 M12 Reader Cable 5 m
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Verify the reader and communication-module assignments before connecting the preassembled cable.
- Allow space for the angled reader connector and avoid tensile loads above the 200 N maximum.
- Use the correct radius for static, repeated or continuous bending rather than applying the single-bend limit to every route.
- Keep the route within the stated temperature range and assess the cable and connector requirements separately.
6GT2891-4JH50 SIMATIC RF RS422 M12 Reader Cable 5 m
Five-metre flexible RS422 reader cable with straight M12 male and angled M12 female connectors, a black PUR sheath and shielding for industrial movement.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6GT2891-4JH50 |
| Product Type | Preassembled reader connection cable |
| Core Function | RS422 connection between communication module and reader |
| Application | SIMATIC RF and MV identification systems |
Ready-made RS422 link
The assembled M12 cable connects a reader to a compatible SIMATIC communication module.
Flexible routing
Specified repeated and continuous bend limits support moving installation design.
Industrial cable construction
The shielded cable uses a PUR outer sheath resistant to mineral oil, grease and UV exposure.
Product Overview
6GT2891-4JH50 is a preassembled SIMATIC RF/MV communication cable for connecting a compatible reader to a communication module. The cable has an angled reader connector and is listed for ASM 456, RF160C, RF170C, RF18XC and RF182C applications.
Its six-core construction combines PVC conductor insulation, a tin-plated copper braid and a black PUR outer sheath. Separate bend radii apply to a single bend, repeated bends and continuous movement, allowing routing to match the actual mechanical duty.
Key Functions
Ready-made RS422 link
The assembled M12 cable connects a reader to a compatible SIMATIC communication module.
Flexible routing
Specified repeated and continuous bend limits support moving installation design.
Industrial cable construction
The shielded cable uses a PUR outer sheath resistant to mineral oil, grease and UV exposure.
Official Specifications
| Cable length | 5 m |
|---|---|
| Connector arrangement | M12 male, 8-pin, straight / M12 female, 8-pin, angled |
| Cable designation | L-YC11Y 6x1x0.25 6x24AWG CM |
| Number of cores | 6 |
| Shield | Tin-plated copper-wire braid |
| Insulation and sheath | PVC conductor insulation; black PUR sheath |
| Outer diameter | 5.4 mm ±0.2 mm |
| Minimum single-bend radius | 21.6 mm |
| Minimum repeated-bend radius | 43 mm |
| Continuous-bending radius | 75 mm |
| Bending cycles | 3,000,000 |
| Maximum tensile load | 200 N |
| Maximum loop resistance | 160 mΩ/m |
| Insulation resistance coefficient | 20 GΩ·m |
| Weight per length | 45 kg/km |
| Temperature range | −30 to +80 °C during operation, storage, transport and installation |
| Fire performance | Flame resistant to IEC 60332-1-2; class Eca to EN 13501-6 |
| Environmental resistance | Resistant to mineral oil, grease and UV radiation |
| Material features | Silicone-free; not halogen-free |
Frequently Asked Questions
Which end of 6GT2891-4JH50 has the angled connector?
The reader end has an angled 8-pin M12 female connector, while the opposite end is a straight 8-pin M12 male connector.
Which communication modules are listed for 6GT2891-4JH50?
Compatible communication modules include ASM 456, RF160C, RF170C, RF18XC and RF182C when used with the matching reader.
What minimum radius applies to continuous movement of 6GT2891-4JH50?
Use the specified 75 mm continuous-bending radius.
Is the 21.6 mm bend radius of 6GT2891-4JH50 suitable for repeated movement?
That figure applies to a single bend; repeated bends require at least 43 mm and continuous bending requires 75 mm.
How many bending cycles are specified for 6GT2891-4JH50?
The specified bending endurance is 3,000,000 cycles.
Is 6GT2891-4JH50 a halogen-free cable?
No; the cable is silicone-free but contains halogens.
Does the UL/ETL CM 300 V statement cover the connectors of 6GT2891-4JH50?
No; the UL/ETL CM 300 V listing applies only to the cable without the plugs.