- Keep the combined RF1000 or MV300 population within the two-device limit.
- Use D-coded network, L-coded power and 8-pin reader connections.
- Include all reader loads when sizing the supply and the 4 A 1L+ demand.
- Preserve connector sealing for IP67 field installation.
SIMATIC IDENT • FOUR-READER CONNECTION
6GT2002-0JE40 SIMATIC RF188C RFID Communication Module
RF188C identification gateway with PROFINET, Industrial Ethernet, EtherNet/IP and OPC UA communication for up to four connected readers.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6GT2002-0JE40 |
| Product Type | RFID communication module |
| Core Function | Identification data access to industrial networks |
| Compatible Series | SIMATIC RF100C communication modules |
Reader concentration
Four readers can be connected, with a maximum of two RF1000 or MV300 devices.
Industrial network access
PROFINET, Ethernet, EtherNet/IP and OPC UA provide controller and application access.
Sealed field connections
M12 network, supply and reader connectors accompany an IP67 enclosure.
Product Overview
6GT2002-0JE40 is the SIMATIC RF188C communication module for integrating identification readers into industrial networks. Its reader interfaces support RS422 and RS232 communication for compatible RFID and optical-identification equipment.
The field enclosure uses D-coded M12 Ethernet connectors, an L-coded M12 supply connection and 8-pin M12 reader connections. Supply sizing must include both the gateway and all connected readers.
Key Functions
Multi-reader integration
Up to four compatible readers are connected, with a two-device limit for the RF1000 and MV300 reader classes.
Protocol gateway
The module makes identification data available through PROFINET, Ethernet, EtherNet/IP and OPC UA.
Distributed field installation
IP67 construction, sealed connectors and a loop-through power path support installation near the identification points.
Official Specifications
| Industrial Ethernet transmission rate | 100 Mbit/s |
|---|---|
| Maximum serial transmission rate | 921.6 kbit/s |
| Reader interface standards | RS422 and RS232 |
| Reader capacity | 4 total; maximum 2 RF1000 or MV300 |
| Ethernet connector | M12, D-coded |
| Reader connectors | M12, 8-pin |
| Power connector | M12, L-coded |
| Rated supply voltage | 24 V DC |
| Permissible supply range | 20.4–28.8 V DC |
| Typical current without connected devices | 0.13 A at 24 V DC |
| Maximum current from 1L+ | 4 A |
| Continuous supply loop-through current | 12 A maximum |
| Local digital I/O | 0 inputs and 0 outputs |
| Degree of protection | IP67 |
| Operating temperature | −25–55 °C |
| Storage and transport temperature | −40–70 °C |
| Housing material | Glass-fiber-reinforced Valox 467 thermoplastic |
Frequently Asked Questions
Can I connect four RF1000 readers to 6GT2002-0JE40?
The four-reader total allows a maximum of two RF1000 or MV300 devices.
Can 6GT2002-0JE40 exchange identification data with an EtherNet/IP controller?
The module supports EtherNet/IP in addition to PROFINET, Ethernet and OPC UA.
Which connector should I prepare for a serial reader on 6GT2002-0JE40?
The reader communication connection uses an 8-pin M12 connector with RS422 or RS232 signaling.
How much supply current does 6GT2002-0JE40 need before readers are added?
The gateway typically draws 0.13 A at 24 V DC without connected devices.
Can I connect a discrete trigger sensor directly to 6GT2002-0JE40?
The communication module has no local digital inputs or outputs.
What current limit applies when looping power through 6GT2002-0JE40?
The continuous power loop-through rating is 12 A maximum.
Can 6GT2002-0JE40 operate at a station ambient of −20 °C?
A −20 °C station lies within the specified −25 to +55 °C operating range.