Siemens SIMATIC PCS 7 Redundant AO8 Marshalled Termination Assembly 6ES7650-1AB51-2XX0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens • SIMATIC PCS 7 / ET 200M

6ES7650-1AB51-2XX0 SIMATIC PCS 7 Redundant AO8 Marshalled Termination Assembly

The redundant AO8 MTA provides eight 4 to 20 mA output channels for redundant connection to the ET 200M analog-output module, with fused redundant supplies, LED indication, shielding and per-channel HART access.

At a Glance

Brand Siemens
Model 6ES7650-1AB51-2XX0
Product Type Eight-channel analog-output marshalled termination assembly
Core Function Terminates and conditions redundant 4 to 20 mA output wiring for an ET 200M analog-output module
Application or Compatible Series SIMATIC PCS 7 ET 200M stations using 6ES7332-5HF00-0AB0 analog-output modules

Exact Identification

Match 6ES7650-1AB51-2XX0 character by character and confirm the complete SIMATIC PCS 7 Redundant AO8 Marshalled Termination Assembly designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The redundant AO8 MTA provides eight 4 to 20 mA output channels for redundant connection to the ET 200M analog-output module, with fused redundant supplies, LED indication, shielding and per-channel HART access.

Dual I/O connectors support the redundant ET 200M analog-output arrangement. Pluggable power and field terminals, channel test points and shield connections simplify maintenance. Each of the eight channels provides connectivity for a HART handheld terminal.

Ordering focus: confirm the complete MTA number, paired ET 200M module revision, eight channel assignments, redundant I/O connectors, power feeds, fuses, shields and HART wiring.
Key Functions

Redundant Module Connection

Dual I/O connectors support the redundant ET 200M analog-output arrangement.

Field-Wiring Serviceability

Pluggable power and field terminals, channel test points and shield connections simplify maintenance.

Channel-Level HART Access

Each of the eight channels provides connectivity for a HART handheld terminal.

Official Specifications
Output Signal Range 4 to 20 mA
Output Resolution 12 bit
Compatible ET 200M Module 6ES7332-5HF00-0AB0, hardware revision 3 or higher
Maximum Output Load Less than 600 Ω
Supply Voltage 24 V DC
Supply Current 0.87 A
Ambient Temperature -25 to +60 °C
Temperature Code T4
I/O Module Connections Dual connectors for redundant operation
HART Access Per channel
Power Protection Per-module fusing
Field Terminal Style Pluggable
Net Weight 0.379 kg
Packaging Dimensions 21.7 x 13.8 x 8.6 cm
Frequently Asked Questions

Which ET 200M output module is paired with 6ES7650-1AB51-2XX0?

Use the specified eight-channel analog-output module at hardware revision 3 or higher.

What field signal does 6ES7650-1AB51-2XX0 terminate?

Each channel carries a 4 to 20 mA analog-output signal.

Can I connect a HART handheld terminal through 6ES7650-1AB51-2XX0?

Yes; dedicated HART access is provided for every output channel.

How is redundant operation wired on 6ES7650-1AB51-2XX0?

Use the two I/O module connectors and the redundant fused power inputs shown for the approved PCS 7 arrangement.

What load limit must be respected with 6ES7650-1AB51-2XX0?

Keep the connected analog-output load below 600 Ω.

What should I record before replacing 6ES7650-1AB51-2XX0?

Document every channel, shield, power feed, jumper position, fuse and I/O connector assignment.

What should I verify after installing 6ES7650-1AB51-2XX0?

Check both power indications, fuses, channel currents, HART access, shielding and redundant switchover behavior.

Compatibility & Ordering Notes
Before ordering 6ES7650-1AB51-2XX0: confirm the complete MTA number, paired ET 200M module revision, eight channel assignments, redundant I/O connectors, power feeds, fuses, shields and HART wiring.

Compatibility Checklist

  • Use the documented ET 200M analog-output module and revision.
  • Keep each 4 to 20 mA loop below the permitted load and preserve shield grounding.
  • Verify both redundant supplies and module paths before returning the process to service.
Hot Selling Models
Allen-Bradley 140MT-C-W453
7T.81.0.000.2403
SAC-4P-M12MSD/0.3-933/M12MSD
NBN8-10GM50-Z0-V1
ABB E250
Allen-Bradley 2760-A485
7T.91.0.000.2303
SGR282 156925 940612
1128361001 RS3124VDCLDLP 1U 043006101300
ZB4BA131
LUA1C11 TeSys-036731
3SU1130-0AB20-1CA0
80118240
101014291
6ES7193-6BP20-0BA0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.