Siemens SIMATIC PCS 7 Redundant AO8 Marshalled Termination Assembly 6ES7650-1AB51-2XX0

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Product Overview
  • Key Functions
  • Official Specifications
  • Quaestiones Frequenter Rogatae
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Producta commendata
Conspectus

Siemens • SIMATIC PCS 7 / ET 200M

6ES7650-1AB51-2XX0 SIMATIC PCS 7 Redundant AO8 Marshalled Termination Assembly

The redundant AO8 MTA provides eight 4 to 20 mA output channels for redundant connection to the ET 200M analog-output module, with fused redundant supplies, LED indication, shielding and per-channel HART access.

Ad Primum Aspectum

Nota Siemens
Modellum 6ES7650-1AB51-2XX0
Typus Producti Eight-channel analog-output marshalled termination assembly
Functio principalis Terminates and conditions redundant 4 to 20 mA output wiring for an ET 200M analog-output module
Applicatio vel series compatibiles SIMATIC PCS 7 ET 200M stations using 6ES7332-5HF00-0AB0 analog-output modules

Identificatio exacta.

Match 6ES7650-1AB51-2XX0 character by character and confirm the complete SIMATIC PCS 7 Redundant AO8 Marshalled Termination Assembly designation.

Arrangementum Interfacis

Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.

Configuration Check

Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.

Product Overview

The redundant AO8 MTA provides eight 4 to 20 mA output channels for redundant connection to the ET 200M analog-output module, with fused redundant supplies, LED indication, shielding and per-channel HART access.

Dual I/O connectors support the redundant ET 200M analog-output arrangement. Pluggable power and field terminals, channel test points and shield connections simplify maintenance. Each of the eight channels provides connectivity for a HART handheld terminal.

Focus ordinandi: confirm the complete MTA number, paired ET 200M module revision, eight channel assignments, redundant I/O connectors, power feeds, fuses, shields and HART wiring.
Key Functions

Redundant Module Connection

Dual I/O connectors support the redundant ET 200M analog-output arrangement.

Field-Wiring Serviceability

Pluggable power and field terminals, channel test points and shield connections simplify maintenance.

Channel-Level HART Access

Each of the eight channels provides connectivity for a HART handheld terminal.

Official Specifications
Intervallum Effectus Signali 4 ad 20 mA
Resolutio Exitus 12 bit
Compatible ET 200M Module 6ES7332-5HF00-0AB0, hardware revision 3 or higher
Maxima Onus Exitus Minus quam 600 Ω
Supple voltage 24 V DC
Currens Alimentaria 0.87 A
Ambiens Temperature -25 to +60 °C
Codex Temperaturae T4
Coniunctiones Moduli I/O Conectores duplices pro operatione redundantia
Accessus HART Per canalem
Tutela Potentiae Fusio per modulum
Stilus Terminalis in Campo Insertionis capax
Ponderis netum 0.379 kg
Dimensiones Confectionis 21.7 x 13.8 x 8.6 cm
Quaestiones Frequenter Rogatae

Which ET 200M output module is paired with 6ES7650-1AB51-2XX0?

Use the specified eight-channel analog-output module at hardware revision 3 or higher.

What field signal does 6ES7650-1AB51-2XX0 terminate?

Each channel carries a 4 to 20 mA analog-output signal.

Can I connect a HART handheld terminal through 6ES7650-1AB51-2XX0?

Yes; dedicated HART access is provided for every output channel.

How is redundant operation wired on 6ES7650-1AB51-2XX0?

Use the two I/O module connectors and the redundant fused power inputs shown for the approved PCS 7 arrangement.

What load limit must be respected with 6ES7650-1AB51-2XX0?

Tene onerem analogicum outputis coniunctum infra 600 Ω.

Quid notare oportet antequam 6ES7650-1AB51-2XX0 substituitur?

Documenta omnem canalum, scutum, alimentationem electricam, positionem iuncturarum, fusibilia et attributionem connexorum I/O.

Quid verificare oportet post installationem 6ES7650-1AB51-2XX0?

Examina utramque indicationem electricae alimentationis, fusibilia, currentes canalium, accessum HART, scutum et comportamentum commutationis redundantis.

Compatibility & Ordering Notes
Antequam 6ES7650-1AB51-2XX0 ordinatur: confirm the complete MTA number, paired ET 200M module revision, eight channel assignments, redundant I/O connectors, power feeds, fuses, shields and HART wiring.

Index Compatibilitatis

  • Utere documentato modulo ET 200M pro output analogico et eius recensione.
  • Tene singulum circuitum 4 ad 20 mA infra onus permissum et serva terram scuti.
  • Verifica utrasque alimentationes redundantis et vias moduli antequam processus ad operationem redigitur.
Hot Selling Models
Allen-Bradley 140MT-C-W453
7T.81.0.000.2403
SAC-4P-M12MSD/0.3-933/M12MSD
NBN8-10GM50-Z0-V1
ABB E250
Allen-Bradley 2760-A485
7T.91.0.000.2303
SGR282 156925 940612
1128361001 RS3124VDCLDLP 1U 043006101300
ZB4BA131
LUA1C11 TeSys-036731
3SU1130-0AB20-1CA0
80118240
101014291
6ES7193-6BP20-0BA0

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.