6ES7492-1AL00-0AA0 SIMATIC S7-400 48-Pole Screw Front Connector

A 48-pole screw-contact front connector for the removable field wiring of S7-400 signal modules.

At a Glance

Brand Siemens
Model 6ES7492-1AL00-0AA0
Product Type Front connector
Core Function Removable signal-module field wiring
Application SIMATIC S7-400 signal modules

Screw-contact termination

Field wiring is secured at the front connector rather than directly on the module body.

Prepared-wire options

Bare flexible conductors and suitable ferruled conductors have distinct cross-section limits.

Module service access

The wired front connector can be prepared separately and removed during module replacement.

Product Overview

6ES7492-1AL00-0AA0 provides the detachable screw-terminal field interface for compatible SIMATIC S7-400 signal modules.

The connector carries the module-specific channel wiring, with conductor preparation, terminal torque and the installed module pin assignment determining the installation.

Ordering focus: Match the exact signal-module connector arrangement, retain the screw-contact version and follow the permitted conductor and tightening limits.
Key Functions

Connect the signal-module field circuits

The 48-pole front connector accepts the channel wiring assigned by the selected S7-400 signal module.

Prepare wiring outside the module

Conductors can be terminated on the prepared front connector before the connector is installed on the module.

Retain field connections during servicing

The removable front wiring interface supports signal-module exchange without reterminating each field wire.

Official Specifications
Contact count 48 poles
Contact termination Screw contacts
Bare flexible conductor range 0.25–2.5 mm²
Ferruled flexible conductor range 0.25–1.5 mm²
Conductors per connection 1; alternatively 2 × 1.0 mm² with a suitable twin ferrule
Stripping length for bare conductors 8–10 mm
Stripping length when using ferrules 10 mm
Terminal tightening torque 0.6–0.8 N·m
Ferrule standard DIN 46228, with or without insulating collar
Approximate connector weight 42 g
Frequently Asked Questions

What wire cross-section can I use without ferrules on 6ES7492-1AL00-0AA0?

Bare flexible conductors may have cross-sections from 0.25 to 2.5 mm².

Can I fit a 2.5 mm² ferruled conductor into 6ES7492-1AL00-0AA0?

No, the permitted range for flexible conductors with ferrules is 0.25–1.5 mm².

How tightly should the screw contacts of 6ES7492-1AL00-0AA0 be fastened?

Tighten each terminal screw to 0.6–0.8 N·m, including terminals that are not wired.

How much insulation should I remove when wiring 6ES7492-1AL00-0AA0 without ferrules?

Strip 8–10 mm of insulation from the conductor before termination.

Can two 1.0 mm² wires share a terminal on 6ES7492-1AL00-0AA0?

Yes, a combination of two 1.0 mm² conductors is permitted when an appropriate special twin ferrule is used.

Where should I begin when terminating a prepared 6ES7492-1AL00-0AA0?

Begin wiring at the bottom of the front connector and work through the remaining connections.

Does 6ES7492-1AL00-0AA0 determine the channel assignment of an S7-400 module?

No, the installed signal-module type determines the function and wiring assignment of the connector contacts.

Compatibility & Ordering Notes
Before ordering 6ES7492-1AL00-0AA0: Choose the screw-contact front connector for the matching S7-400 signal module, follow that module’s terminal assignment and size conductors for their actual end preparation.

Compatibility Checklist for 6ES7492-1AL00-0AA0

  • Match the signal-module front interface and contact assignment.
  • Use 10 mm stripping when fitting ferrules.
  • Apply 0.6–0.8 N·m to terminal screws.
  • Retain suitable shielded field cables for analog circuits.
Hot Selling Models
SLC500 1746-IB32
ES7193-4CG20-0AA0
6GT2691-4FH20
3SE5132-0CJ82
IM0053 IMC2035-ABOA/SL/LS
MC9-01
6ES5951-7LB14
0822 394 203
DD-83 106887
ADVU-32-10-APA-S2
TM-1-8240
516-325-B0-C
P1PN/3x380V~/1a1r 486855
LF1/8SB
SK3322267

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.