Overview
SIEMENS SIMATIC S7-400

6ES7421-1FH20-0AA0 SIMATIC S7-400 SM 421 16DI 120/230 V UC Module

An isolated 16-channel SM 421 input module for 120/230 V UC signals, using IEC 61131 Type 2 input characteristics.

At a Glance

Brand Siemens
Model 6ES7421-1FH20-0AA0
Product Type SM 421 digital input module
Core Function Acquiring high-voltage AC or DC discrete signals
Application S7-400 I/O racks

Universal-current inputs

The signal circuits accept the specified AC or positive and negative DC signal levels.

All-channel operation

All 16 inputs can be controlled simultaneously.

Defined response timing

AC and DC inputs have different maximum rising- and falling-edge delays.

Product Overview

6ES7421-1FH20-0AA0 acquires 16 discrete field signals in an S7-400 rack using 120/230 V UC input circuits and Type 2 input characteristics.

The module separates the input circuits in groups of four and isolates them from the backplane bus, while individual green indicators display the input states.

Ordering focus: Match the AC or DC signal thresholds, four-channel potential groups and sensor leakage to the installation.
Key Functions

Accept AC or DC field states

The input circuits use rated 120/230 V UC signals with separately specified AC and DC switching thresholds.

Acquire all installed channels

All 16 digital inputs can be controlled simultaneously.

Show the field-input state

A green status indication is provided for the digital inputs, while the module does not provide diagnostic functions.

Official Specifications
Digital Input Channels 16, all simultaneously controllable
Rated Input Signal 120/230 V UC; AC frequency 47–63 Hz
Input Characteristic IEC 61131 Type 2
OFF-State Input Voltage 0–40 V AC or −40 to +40 V DC
ON-State Input Voltage 74–264 V AC; 80–264 V DC or −264 to −80 V DC
Typical ON-State Input Current At 120 V: 10 mA AC or 1.8 mA DC; at 230 V: 14 mA AC or 2 mA DC
Maximum Rising-Edge Delay 20 ms AC; 15 ms DC
Maximum Falling-Edge Delay 30 ms AC; 25 ms DC
Maximum Signal-Cable Length 1000 m shielded; 600 m unshielded
Maximum Two-Wire Sensor Quiescent Current 5 mA AC
Input Isolation Arrangement Four-channel groups; isolated from backplane bus
Insulation Test Voltage 1500 V AC
Maximum Backplane Current 80 mA from 5 V DC
Typical Power Dissipation 12 W
Input Status Display Green LEDs
Dimensions (W × H × D) 25 × 290 × 210 mm
Approximate Weight 650 g
Official source:Siemens SM 421 data sheet
Frequently Asked Questions

Can 6ES7421-1FH20-0AA0 accept both AC and DC switching signals?

The UC input circuits accept the specified AC and DC signal ranges.

Will 6ES7421-1FH20-0AA0 recognize 24 V DC as an ON signal?

The positive DC ON range starts at 80 V.

Can every channel of 6ES7421-1FH20-0AA0 be active at the same time?

All 16 inputs can be controlled simultaneously.

How are the input circuits of 6ES7421-1FH20-0AA0 grouped for isolation?

The inputs are isolated in groups of four and from the backplane bus.

What leakage limit applies to an AC two-wire sensor connected to 6ES7421-1FH20-0AA0?

The maximum permissible quiescent current is 5 mA.

Should I use 6ES7421-1FH20-0AA0 for a very short AC pulse?

Allow for maximum AC input delays of 20 ms on a rising edge and 30 ms on a falling edge.

Can 6ES7421-1FH20-0AA0 report channel diagnostic faults?

The module has input-state indicators but no diagnostic functions.

Compatibility & Ordering Notes
Before ordering 6ES7421-1FH20-0AA0: Select the high-voltage UC input module and match every field circuit to the required signal thresholds, isolation group and response timing.

Compatibility Checklist for 6ES7421-1FH20-0AA0

  • Use 120/230 V UC field-signal arrangements.
  • Keep positive DC ON signals within 80–264 V.
  • Respect the four-channel potential groups.
  • Limit two-wire AC sensor quiescent current to 5 mA.
  • Budget 80 mA from the 5 V backplane and 12 W typical heat dissipation.
Hot Selling Models
L4MG/RJ45G-GS-5m-PUR
3RV2021-4BA10 3RT2026-1AL20 3RH2911-1HA22
KLI10020040001-020097
FPF-285-F-3-011
BES01EL BES516-329-BO-C-PU-05
3RT2025-2BB44
4024-3AF01-2AA1-PF
D1VW20BNJW75
3VA9403-0QE00
114 943 026-021
9454
R07-1FK-NNEG
14117118
1085243
4.4T-15-RSC 4.4T/S3060 U-36832

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.