SIMATIC S7-300

6ES7350-1AH02-0AE0 SIMATIC S7-300 FM350-1 Counter Module

A single-channel FM350-1 counter with 5 V RS422 and 24 V encoder connections, gate inputs and local outputs.

At a Glance

Brand Siemens
Model 6ES7350-1AH02-0AE0
Product Type High-speed counter module
Core Function Independent incremental counting
Application S7-300 pulse and encoder applications

Fast pulse acquisition

The counter accepts up to 500 kHz through its 5 V RS422 input.

Hardware gate control

Three digital inputs provide separate start, stop and counter-setting functions.

Local switching outputs

Two protected outputs can switch field loads within the permitted current range.

Product Overview

6ES7350-1AH02-0AE0 counts external pulses independently of the S7-300 CPU scan.

One counter channel supports 5 V differential or 24 V signals, while dedicated digital inputs control gate start, gate stop and counter setting.

Ordering focus: Match the encoder voltage, signal frequency, counter format, gate wiring and 20-pin front connection.
Key Functions

Fast pulse acquisition

The counter accepts up to 500 kHz through its 5 V RS422 input.

Hardware gate control

Three digital inputs provide separate start, stop and counter-setting functions.

Local switching outputs

Two protected outputs can switch field loads within the permitted current range.

Official Specifications
Nominal auxiliary and load voltage 24 V DC; static range 20.4–28.8 V; dynamic limits 18.5–30.2 V
Maximum 1L+ current without load 40 mA
Maximum 5 V backplane current 160 mA
5 V encoder supply 5.2 V ±2%; maximum current 300 mA
24 V encoder supply 1L+ minus 3 V; maximum current 300 mA
Typical power loss 4.5 W
Gate and setting inputs 3 digital inputs: gate start, gate stop and counter setting
Digital-input thresholds Signal zero: −28.8 to +5 V; signal one: +11 to +28.8 V
Digital-output quantity 2 outputs with electronic short-circuit protection
Nominal output current 0.5 A; permissible on-state range 5 mA–0.6 A
Maximum output turn-on delay 300 µs with a resistive load
Counter format One 32-bit or ±31-bit counter
5 V counter input RS422; 220 Ω termination; 0.5 V differential input voltage
Maximum counting frequencies 500 kHz at 5 V; 200 kHz at 24 V
24 V minimum pulse width 2.5 µs
Backplane isolation Optocoupler isolation for digital inputs, outputs and counter
Isolation test voltage 500 V
Front connector One 20-pin connector
Dimensions and approximate mass 40 × 125 × 120 mm (W × H × D); 250 g
Frequently Asked Questions

Can 6ES7350-1AH02-0AE0 count 24 V pulses at 500 kHz?

The 24 V input is limited to 200 kHz, while the 5 V RS422 input supports 500 kHz.

Can 6ES7350-1AH02-0AE0 process two encoder pulse trains shifted by 90 degrees?

The module accepts symmetrical incremental encoder signals with two pulse trains offset by 90 degrees.

What do the three auxiliary digital inputs of 6ES7350-1AH02-0AE0 control?

The inputs provide gate start, gate stop and counter-setting functions.

How much current is available from either encoder supply on 6ES7350-1AH02-0AE0?

Each encoder supply has a maximum output current of 300 mA.

Does the 5 V counter input of 6ES7350-1AH02-0AE0 include termination?

The RS422 counter input has a 220 Ω terminating resistor.

How many local outputs are provided by 6ES7350-1AH02-0AE0?

The module provides two electronically protected digital outputs rated at 0.5 A.

Which front connector is needed for 6ES7350-1AH02-0AE0?

Use one 20-pin front connector.

Compatibility & Ordering Notes
Before ordering 6ES7350-1AH02-0AE0: Match the encoder voltage, signal frequency, counter format, gate wiring and 20-pin front connection.

Before installation

  • Match the selected encoder interface to its voltage and maximum pulse frequency.
  • Wire the start, stop and setting inputs to the intended gate-control arrangement.
  • Size the field load supply and output loads within the stated current limits.
  • Include a 20-pin front connector and the appropriate station configuration package.
Hot Selling Models
IE-3001-ANOG
XN-2AI-PT/NI-2/3 85 50 225181 XN-S4T-SBBS
BOS00Y0 BOS 21M-XT-LS11-S4
C-131-03/L
110.240.5164
DWI11A 8227594.12
D-6-3-31
BES516324E0CPU05
EMU-CT 100 19E 212 AC100A
GV2ME16 034317 9-14A
0821302813
21M-PA-LE10-S4
II5284 IIA3015-BPKG
6ES5943-7UA11
DBG60B-01

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.