Siemens SIMATIC S7-300 6ES7322-1HH01-0AA0 SM 322 Relay Output
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · SIMATIC S7-300
6ES7322-1HH01-0AA0 SM 322 Sixteen-Channel Relay Output Module
Siemens 6ES7322-1HH01-0AA0 is the SIMATIC S7-300 SM 322 relay output module with sixteen isolated outputs in groups of eight for 24 to 120 V DC and 24 to 230 V AC loads.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7322-1HH01-0AA0 |
| Product Type | Sixteen-channel isolated relay output module |
| Core Function | Switches AC and DC industrial loads through relay contacts |
| Application or Compatible Series | SIMATIC S7-300 and ET 200M control systems |
Load Classification
Check every solenoid, contactor, motor starter or lamp against the relay contact rating.
Group Current
Calculate the total current for each eight-channel group and the installed mounting position.
Connector Transfer
Preserve the twenty-pin connector assignment, coil supply, contact wiring and external protection.
Product Overview
Siemens 6ES7322-1HH01-0AA0 is the SIMATIC S7-300 SM 322 relay output module with sixteen isolated outputs in groups of eight for 24 to 120 V DC and 24 to 230 V AC loads.
Relay contacts switch AC or DC loads without requiring one common load type. Outputs are electrically isolated in two groups of eight and isolated from the backplane bus. The module supports 24 to 120 V DC and 24 to 230 V AC load circuits.
Key Functions
Sixteen Relay Outputs
Relay contacts switch AC or DC loads without requiring one common load type.
Grouped Isolation
Outputs are electrically isolated in two groups of eight and isolated from the backplane bus.
Broad Load Voltage
The module supports 24 to 120 V DC and 24 to 230 V AC load circuits.
Official Specifications
| Number of Digital Outputs | 16 relay outputs |
|---|---|
| Output Grouping | 2 groups of 8 |
| DC Load Voltage Range | 24 to 120 V DC |
| AC Load Voltage Range | 24 to 230 V AC |
| Rated Coil Supply | 24 V DC |
| Rated Contact Current | 2 A |
| Maximum Lamp Load | 50 W at 230 V AC |
| Maximum Total Current per Group | 8 A |
| Maximum Mechanical Switching Frequency | 10 Hz |
| Maximum Lamp-Load Switching Frequency | 1 Hz |
| Maximum Inductive-Load Switching Frequency | 0.5 Hz |
| Maximum Backplane Current at 5 V DC | 100 mA |
| Typical Power Loss | 4.5 W |
| Maximum Shielded Cable Length | 1,000 m |
| Maximum Unshielded Cable Length | 600 m |
| Isolation Test Voltage | 1,500 V AC |
| Output Status Indication | Green LED per output |
| Required Front Connector | 20-pin |
| Dimensions | 40 x 125 x 120 mm |
| Approximate Weight | 250 g |
Frequently Asked Questions
Which loads can I switch with 6ES7322-1HH01-0AA0?
Use AC or DC solenoid valves, contactors, motor starters, fractional-horsepower motors or signal lamps within the contact ratings.
How are the outputs grouped on 6ES7322-1HH01-0AA0?
The sixteen relay channels are electrically isolated in two groups of eight.
What current can one output of 6ES7322-1HH01-0AA0 carry?
Each contact is rated for two amperes within the specified load conditions.
Does 6ES7322-1HH01-0AA0 provide short-circuit protection?
No, select external circuit protection appropriate for the connected loads and wiring.
Which connector fits 6ES7322-1HH01-0AA0?
Use the specified twenty-pin front connector and preserve the original terminal mapping.
Why should switching frequency be checked for 6ES7322-1HH01-0AA0?
Permitted frequency depends on whether the load is resistive, inductive, a lamp or only a mechanical operation.
What should I inspect before energizing 6ES7322-1HH01-0AA0?
Check load voltage, contact current, group current, external protection, connector wiring and coil supply.
Compatibility & Ordering Notes
Compatibility Checklist
- Confirm the station is configured for the sixteen-channel relay SM 322 rather than a transistor-output variant.
- Check every load voltage, current, switching category and group-current total.
- Retain the twenty-pin connector mapping and provide suitable external circuit protection.