siemens 6es7231 0hc22 0xa8 s7 200 cn em 231 analog input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7231-0HC22-0XA8 S7-200 CN EM 231 Analog Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC S7-200 CN

6ES7231-0HC22-0XA8 S7-200 CN EM 231 Analog Input Module

Four differential analog inputs for voltage and current measurements, using 12-bit conversion in an S7-200 CN expansion system.

At a Glance

Brand Siemens
Model 6ES7231-0HC22-0XA8
Product Type Analog input expansion module
Core Function Conversion of process measurements
Application CPU 22x analog acquisition

Four analog inputs

Differential channels acquire voltage or current process signals.

Fast conversion

Analog-to-digital conversion takes less than 250 µs.

Signal-reference planning

The inputs have no field-to-logic isolation.

Product Overview

6ES7231-0HC22-0XA8 adds four differential analog input channels to the SIMATIC S7-200 CN CPU 22x expansion system. Voltage and current measurement functions support process transmitters and other analog signal sources.

Input selection and signal grounding need to suit the common-mode limits of this non-isolated module. The 12-bit conversion system uses separate unipolar and bipolar numeric ranges for scaling in the controller program.

Ordering focus: Match the input signal range and differential reference, then include the module’s external 24 V and backplane 5 V demands in the system power budget.
Key Functions

Acquire differential measurements

Four differential channels accept the selected voltage or current range, with high input impedance for voltage signals.

Convert process values

Conversion takes less than 250 µs and the analog step response reaches 95% in 1.5 ms.

Interface with current loops

The 0–20 mA current input presents a 250 Ω load to the connected loop.

Official Specifications
Analog input channels 4 differential inputs
Conversion resolution 12 bits unipolar; 11 bits plus sign bipolar
Current input range 0–20 mA
Voltage-input impedance At least 2 MΩ
Current-input impedance 250 Ω
Maximum input conversion time Less than 250 µs
Analog step response 1.5 ms to 95%
Input destruction limits 30 V DC or 32 mA maximum
Signal and common-mode limit Signal voltage plus common-mode voltage within ±12 V
Analog data scaling 0–32000 unipolar; −32000 to +32000 bipolar
External supply range 20.4–28.8 V DC
Supply-current requirements 20 mA from the 5 V backplane; 60 mA from external 24 V DC
Field-to-logic isolation None
Typical power loss 2 W
Dimensions and weight 71.2 × 80 × 62 mm (W × H × D); approximately 183 g
Frequently Asked Questions

Can 6ES7231-0HC22-0XA8 acquire four analog signals without adding an output channel?

The EM 231 provides four differential analog inputs.

How much loop load does a current input on 6ES7231-0HC22-0XA8 add?

The current input adds a resistance of 250 Ω.

What is the conversion speed of 6ES7231-0HC22-0XA8 for an input channel?

Analog-to-digital conversion takes less than 250 µs.

How does 6ES7231-0HC22-0XA8 represent a unipolar full-scale signal in the PLC?

A unipolar full-scale input is represented by the value 32000.

Can I ignore ground-potential differences when wiring 6ES7231-0HC22-0XA8?

Signal voltage plus common-mode voltage must remain within ±12 V because the inputs are not isolated from logic.

Can 6ES7231-0HC22-0XA8 directly measure a resistance-temperature sensor?

The module supports voltage and current measurements rather than direct resistance or resistance-temperature measurement.

What supply range can I use for the external power connection of 6ES7231-0HC22-0XA8?

The external 24 V DC supply must stay between 20.4 and 28.8 V DC.

Compatibility & Ordering Notes
Before ordering 6ES7231-0HC22-0XA8: Match the S7-200 CN analog-input version, signal range and reference-potential arrangement for the connected transmitters.

Compatibility Checklist for 6ES7231-0HC22-0XA8

  • Use the CPU 22x expansion system.
  • Include 20 mA at 5 V and 60 mA at 24 V in the power budget.
  • Keep voltage plus common-mode voltage within ±12 V.
  • Select voltage or current measurement rather than direct temperature-sensor conversion.
Hot Selling Models
efector200 E21107
OS5015OSS-OOKG
PLC-BSC-24DC/21HC 2967772
769-171 51214115
6EC1110-3A
Crouzet 84721
GV2ME05AE11
DILM7-10 A-XHI20
221-1BF21
R163219423 KWD015SNSC0N1
3842521342
VQ1400N5Q
DSNU125PA
5-24DC/2x5/1x10 2868606