Overview
SIEMENS · SIMATIC ET 200iSP
6ES7152-1BA00-0AB0 SIMATIC ET 200iSP IM 152-1PN Interface Module
The IM 152-1PN connects ET 200iSP distributed I/O to PROFINET IO and supports standard operation, redundant configurations and configuration changes during operation.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7152-1BA00-0AB0 |
| Product Type | PROFINET interface module for intrinsically safe distributed I/O |
| Core Function | Connects an ET 200iSP station to PROFINET IO with standard or redundant operation |
| Application or Compatible Series | ET 200iSP stations in process automation and hazardous-area architectures |
Exact Identification
Match 6ES7152-1BA00-0AB0 character by character and confirm the complete SIMATIC ET 200iSP IM 152-1PN Interface Module designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The IM 152-1PN connects ET 200iSP distributed I/O to PROFINET IO and supports standard operation, redundant configurations and configuration changes during operation.
The interface provides PROFINET V2.3 real-time communication for ET 200iSP. System redundancy R1 is supported with two interface modules in the designated configuration. A station can contain up to 56 supported I/O modules with up to 256 bytes per module.
Key Functions
PROFINET Integration
The interface provides PROFINET V2.3 real-time communication for ET 200iSP.
Redundant Architecture
System redundancy R1 is supported with two interface modules in the designated configuration.
Large Station Capacity
A station can contain up to 56 supported I/O modules with up to 256 bytes per module.
Official Specifications
| Interface Type | PROFINET IO V2.3 RT |
|---|---|
| Minimum Cycle Time | 250 µs |
| Maximum I/O Modules | 56 |
| Maximum User Data per I/O Module | 256 bytes |
| System Redundancy | R1 supported |
| Configuration Changes in RUN | Supported |
| Firmware Baseline | V1.0 |
| STEP 7 Baseline | V5.7 SP1 with current hardware update |
| PCS 7 Baseline | V9.1 SP2 with current ET 200iSP HSP |
| TIA Portal Baseline | V18 |
| Network Connection | Ethernet with RJ45 or certified optical connection components |
| Hazardous-Area Enclosure | Ex e enclosure required for Zone 1 installation |
Frequently Asked Questions
Which fieldbus is used by 6ES7152-1BA00-0AB0?
It connects the ET 200iSP station through PROFINET IO.
Can 6ES7152-1BA00-0AB0 be used in an R1 redundant station?
Yes; R1 system redundancy is supported with the specified two-module configuration.
How many I/O modules can be managed by 6ES7152-1BA00-0AB0?
The supported maximum is 56 I/O modules.
Can the ET 200iSP configuration be changed while 6ES7152-1BA00-0AB0 is running?
Yes; configuration changes during operation are supported.
Which engineering baseline applies to 6ES7152-1BA00-0AB0 in STEP 7 Classic?
Use STEP 7 V5.7 SP1 with the current hardware update.
What enclosure consideration applies to 6ES7152-1BA00-0AB0 in Zone 1?
Install the ET 200iSP station in a suitable Ex e enclosure.
What must be checked before converting to 6ES7152-1BA00-0AB0 from a PROFIBUS interface?
Confirm hardware compatibility, engineering software, power consumption and the complete PROFINET addressing plan.
Compatibility & Ordering Notes
Compatibility Checklist
- Confirm all installed ET 200iSP modules are released for the selected interface firmware.
- Plan unique PROFINET device names, IP addresses and topology for each interface.
- Check the power-supply calculation because the PROFINET module consumes more functional current than the DP version.