SIEMENS SIMATIC ET 200S

6ES7132-4BD31-0AA0 ET 200S 4DO 24VDC 2A ST Module

Four 24 V DC transistor outputs rated at 2 A each, with a 4 A module limit and an extended vertical operating range up to 55 °C.

At a Glance

Brand Siemens
Model 6ES7132-4BD31-0AA0
Product Type Standard digital output module
Core Function Switching of field actuators
Application Distributed valve and contactor circuits

2 A channels

Four output channels drive solenoid valves, DC contactors or indicators.

4 A total

The combined module output current remains limited to 4 A.

Local status

A green LED indicates each output state.

Product Overview

6ES7132-4BD31-0AA0 provides four standard digital outputs for an ET 200S station. The module is suited to solenoid valves, DC contactors and indicator lights, with a 2 A rated current per output and a 4 A maximum module total.

Per-channel short-circuit protection limits output faults, while the green LEDs indicate output states without a diagnostic function. The vertical installation temperature limit reaches 55 °C.

Ordering focus: Coordinate the actuator loads with both the 2 A channel rating and 4 A module limit, and choose the appropriate 15 mm terminal module.
Key Functions

Operate DC actuators

The four output channels switch 24 V DC loads, with a minimum ON-state output voltage of L+ minus 1 V.

Protect individual output circuits

Per-channel short-circuit protection has a typical pickup threshold from 2.8 to 7.2 A.

Support compact addressing

The normal output address space is one byte, or four bits when packed addressing is used.

Official Specifications
Output channels 4
Rated load voltage 24 V DC from the power module
Rated output and module current 2 A per channel; 4 A maximum per module
Permitted signal-1 current 7 mA–2.4 A
Signal-0 leakage current 0.5 mA maximum
Minimum signal-1 voltage L+ minus 1 V
Maximum resistive-load delay 200 µs on; 1.3 ms off
Load-resistance range 12 Ω–3.4 kΩ
Maximum lamp load 10 W
Switching rates 100 Hz resistive; 2 Hz with a 0.5 H inductive load; 10 Hz lamp load
Short-circuit pickup threshold 2.8–7.2 A typical, per channel
Internal inductive interruption limit Typically L+ minus 55–60 V
Maximum cable length 1,000 m shielded; 600 m unshielded
Output address and parameter allocation 1 byte output space or 4 bits packed; 1 byte parameters
Maximum no-load consumption 5 mA per channel from load voltage L+
Typical power dissipation 1.6 W
Electrical isolation and test No channel isolation; isolated from backplane bus; tested at 500 V DC
Permissible circuit potential difference 75 V DC or 60 V AC
Vertical operating temperature 0 to +55 °C
Module width and weight 15 mm; approximately 40 g
Frequently Asked Questions

Can all four channels of 6ES7132-4BD31-0AA0 supply 2 A simultaneously?

The module total is limited to 4 A even though each channel has a 2 A rating.

Which output terminals on 6ES7132-4BD31-0AA0 correspond to channels 0 and 1?

Channel 0 uses terminal 1 and channel 1 uses terminal 5.

Can 6ES7132-4BD31-0AA0 operate vertically at 55 °C?

The extended vertical operating range is 0 to +55 °C.

How should I allocate packed output addresses for 6ES7132-4BD31-0AA0?

Packed addressing occupies four output bits instead of the normal one-byte output allocation.

Can the LEDs on 6ES7132-4BD31-0AA0 report a short-circuit diagnostic?

The green LEDs indicate output states and the module does not provide a diagnostic function.

Can I parallel two channels of 6ES7132-4BD31-0AA0 to drive a larger actuator?

Parallel connection is allowed for redundant triggering within one module but not for increasing output capability.

What startup pulse should a high-speed receiver tolerate when powered through 6ES7132-4BD31-0AA0?

Switching the power-module load supply through a mechanical contact can produce an approximately 50 µs signal-1 pulse on the outputs.

Compatibility & Ordering Notes
Before ordering 6ES7132-4BD31-0AA0: Select the four-channel Standard module and match terminal style, actuator current and station load supply.

Compatibility Checklist for 6ES7132-4BD31-0AA0

  • Use a compatible TM-E15 terminal module in the required spring, screw or Fast Connect design.
  • Keep the aggregate output current within 4 A.
  • Do not use parallel channels to increase load capability.
  • Account for the possible 50 µs pulse when load power is switched by a mechanical contact.
Hot Selling Models
3TX7014-1BF00
4000-68000-1610000
EL2809
NBN7-12GM35-E2-V1
Pilz PA-1SKS/30s/FBM:16M
NJ2-12GK40-E2
3E 4003346
65-10z 1055787
1055824
3NA7136
SDE1-D10-G2-R18-C-P2-M12
WT232P2441
BMF004Y BMF 305K-NS-C-2-PU-05
6ES7131-0BL00-0XB0 6ES7193-0CB10-0XA0
3RH2131-1BB40 3RT2916-1CB00

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.