Siemens 6ES5188-3UH51 SIMATIC S5-155H CC 155H Subrack
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Select the power supplies, CPUs, interface modules and cooling assembly for the intended station arrangement.
- Place power supplies at the left of each subunit and CPUs and linking interfaces in the assigned positions.
- Set the backplane jumpers for central-controller, shared-expansion or split operation as required.
- Cover unused positions with appropriate dummy front plates and use the corresponding labeling strips.
6ES5188-3UH51 SIMATIC S5-155H CC 155H Subrack
A divided subrack with two electrically separate areas for fault-tolerant central-controller and switched-expansion configurations.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES5188-3UH51 |
| Product Type | Controller subrack |
| Core Function | Modular controller and expansion assembly |
| Application | Fault-tolerant CC 155H systems |
Separated subunit backplanes
The first ten slots and remaining eleven slots belong to electrically separate subunits.
Several station arrangements
The rack supports central-controller, shared-expansion and split CC/EU configurations.
Retained module layout
A locking bar and labeling strips support identification and retention of the installed modules.
Product Overview
6ES5188-3UH51 provides the divided mounting and backplane structure for a CC 155H assembly.
Each subunit has its own assigned module positions, allowing the rack to operate as a central controller, a shared switched expansion unit or a split central-controller and expansion-unit arrangement.
Key Functions
Separated subunit backplanes
The first ten slots and remaining eleven slots belong to electrically separate subunits.
Several station arrangements
The rack supports central-controller, shared-expansion and split CC/EU configurations.
Retained module layout
A locking bar and labeling strips support identification and retention of the installed modules.
Official Specifications
| Backplane arrangement | 2 electrically separated areas |
|---|---|
| Slot allocation | 10 positions in subunit 1, BEP 3–75; 11 positions in subunit 2, BEP 83–163 |
| Extreme-right slot access | Only 8-bit data-bus access at the two rightmost slots of each subunit |
| Module retention | Locking bar with labeling strip |
Frequently Asked Questions
Can 6ES5188-3UH51 be configured as an expansion rack instead of a central controller?
The subrack supports central-controller, shared switched-expansion and split CC/EU arrangements.
Are the two subunit backplanes in 6ES5188-3UH51 electrically separate?
The subrack is divided into two electrically separated areas.
Where should I place the CPU in each subunit of 6ES5188-3UH51?
The CPU is inserted immediately to the right of the power supply unit.
Can I use multiprocessor operation within a CC 155H built on 6ES5188-3UH51?
Multiprocessor operation is not supported in the CC 155H.
Which interface pair links the two central-controller subunits in 6ES5188-3UH51?
The central-controller arrangement uses the IM 304 and IM 324R interface pair.
Why should I cover unused slots in 6ES5188-3UH51?
Dummy front plates direct the cooling air and prevent contact with the inside of unused slots.
What restriction applies to modules in the far-right slots of 6ES5188-3UH51?
Only modules with an 8-bit-wide data-bus connection may occupy the two extreme-right slots of each subunit.