Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6dl1136 6aa00 0ph1 et 200sp ha f ai 8xi hart fail safe analog input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens ET 200SP HA F-AI 8xI HART Fail-Safe Analog Input Module 6DL1136-6AA00-0PH1

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens • SIMATIC ET 200SP HA

6DL1136-6AA00-0PH1 ET 200SP HA F-AI 8xI HART Fail-Safe Analog Input Module

The F-AI 8xI module provides eight 16-bit, two-wire or four-wire HART current inputs with channel diagnostics, redundant-operation support and fail-safe use up to SIL 3 or PL e.

At a Glance

Brand Siemens
Model 6DL1136-6AA00-0PH1
Product Type Fail-safe analog input module
Core Function Acquires safety-related process measurements for protective functions
Application or Compatible Series ET 200SP HA and PCS 7 safety applications

Exact Identification

Match 6DL1136-6AA00-0PH1 character by character and confirm the complete ET 200SP HA F-AI 8xI HART Fail-Safe Analog Input Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The F-AI 8xI module provides eight 16-bit, two-wire or four-wire HART current inputs with channel diagnostics, redundant-operation support and fail-safe use up to SIL 3 or PL e.

Eight channels support safety-related current measurement for process transmitters. HART communication and per-channel diagnostics support device access and maintenance. The module can be used redundantly with the documented F1 terminal block arrangement.

Ordering focus: confirm the exact fail-safe module number, firmware, terminal-block type, redundancy arrangement, channel ranges, HART devices, F parameters and safety acceptance plan.
Key Functions

Fail-Safe Current Acquisition

Eight channels support safety-related current measurement for process transmitters.

HART and Channel Diagnostics

HART communication and per-channel diagnostics support device access and maintenance.

Redundant Station Option

The module can be used redundantly with the documented F1 terminal block arrangement.

Official Specifications
Firmware Version V1.0
Firmware Update Supported
Usable Terminal Blocks H1, F1, H0 and N0
Module Color Code CC00
Identification and Maintenance Data I&M0 to I&M3
Redundant Operation Supported with F1 terminal block
Rated Supply Voltage 24 V DC
Permissible Supply Range 19.2 to 28.8 V DC
Reverse-Polarity Protection Supported
Rated Current Consumption 90 mA without sensor supply
Sensor Supply Outputs 8, short-circuit protected
Maximum Sensor-Supply Current per Channel 30 mA
Backplane-Bus Power 90 mW
Power Loss 2.8 W typical; 3.3 W maximum
Address Space 22 input bytes and 5 output bytes
Analog Input Channels 8
Current Input Destruction Limit 35 mA
Supported Input Ranges 0 to 20 mA and 4 to 20 mA
Input Resistance 150 Ω
HART Role Primary master
Frequently Asked Questions

Which terminal blocks can I use with 6DL1136-6AA00-0PH1?

Use an approved H1, F1, H0 or N0 terminal block according to the station design.

How do I configure redundant operation for 6DL1136-6AA00-0PH1?

Use the documented F1 terminal-block arrangement and the corresponding redundant hardware configuration.

Can 6DL1136-6AA00-0PH1 power connected transmitters?

Yes; each of the eight short-circuit-protected sensor supplies can deliver up to 30 mA.

Which current ranges are accepted by 6DL1136-6AA00-0PH1?

Configure supported channels for 0 to 20 mA or 4 to 20 mA measurement.

Does 6DL1136-6AA00-0PH1 act as a HART primary master?

Yes; assign the HART communication and device parameters for each applicable channel.

What safety information should I archive before replacing 6DL1136-6AA00-0PH1?

Retain the PCS 7 project, F parameters, signatures, channel assignments, terminal-block type and acceptance records.

What validation is required after installing 6DL1136-6AA00-0PH1?

Test channel wiring, transmitter supply, range scaling, diagnostics, HART communication, redundancy and the approved safety functions.

Compatibility & Ordering Notes
Before ordering 6DL1136-6AA00-0PH1: confirm the exact fail-safe module number, firmware, terminal-block type, redundancy arrangement, channel ranges, HART devices, F parameters and safety acceptance plan.

Compatibility Checklist

  • Use the terminal block and redundancy mode defined by the approved station design.
  • Preserve the safety program, F parameters and acceptance documentation.
  • Validate every analog channel and diagnostic path before returning the safety function to service.
Hot Selling Models
AK1233 090606
ZB5AK1213 013790
6ES7132-4HB01-0AB0
FLZ 530
7000-41161-0000000
XB5 AV61 090396
CHCC1D
NEBV-Z3WA2L-RE-5-N-LE2-S1
LUFC00 036550
TL-X8MF1-M1-E1
IN02VB
NBN10-F10-E2-V1
V1G 117051
MYM-A16L
753-530 8D0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.