Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6dl1132 6bh00 0eh1 et 200sp ha dq 16x24vdc-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC ET 200SP HA 6DL1132-6BH00-0EH1 DQ 16x24VDC

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC ET 200SP HA

6DL1132-6BH00-0EH1 DQ 16x24VDC/0.5A HA Module

Siemens 6DL1132-6BH00-0EH1 is the SIMATIC ET 200SP HA DQ 16x24VDC/0.5A high-availability digital output module with channel diagnostics and optional I/O redundancy using the matching terminal block.

At a Glance

Brand Siemens
Model 6DL1132-6BH00-0EH1
Product Type Sixteen-channel high-availability digital output module
Core Function Switches sixteen 24 V DC loads at up to 0.5 A per channel
Application or Compatible Series SIMATIC ET 200SP HA and SPPA-T3000 systems

Terminal Block

Use terminal-block type H1 for a single module or M1 when I/O redundancy is required.

Load Engineering

Check channel current, module total-current derating and inductive or lamp switching limits.

Diagnostic Wiring

Preserve supply monitoring, wire-break and short-circuit diagnostic parameters during replacement.

Product Overview

Siemens 6DL1132-6BH00-0EH1 is the SIMATIC ET 200SP HA DQ 16x24VDC/0.5A high-availability digital output module with channel diagnostics and optional I/O redundancy using the matching terminal block.

Each 24 V DC output includes short-circuit and overload protection for process loads. Two modules can control a load redundantly when installed with the specified M1 terminal block. Wire break and short circuits to M or L+ are diagnosed channel by channel.

Ordering focus: confirm the H1 or M1 terminal block, channel load currents, module current derating, redundancy pairing, diagnostic settings and SPPA-T3000 project version.
Key Functions

Sixteen Protected Outputs

Each 24 V DC output includes short-circuit and overload protection for process loads.

High-Availability Redundancy

Two modules can control a load redundantly when installed with the specified M1 terminal block.

Channel-Level Diagnostics

Wire break and short circuits to M or L+ are diagnosed channel by channel.

Official Specifications
Firmware Version V1.0
Compatible Terminal Blocks Type H1 and M1
Module Color Code CC02
SPPA-T3000 Integration V8.0 or higher
Redundancy Arrangement Supported with terminal-block type M1
Rated Supply Voltage 24 V DC
Permitted Supply Range 19.2 to 28.8 V DC
No-Load Current Consumption 60 mA rated; 70 mA maximum
Typical Power Loss 1.2 W, load dependent
Maximum Address Space 8 bytes including QI and PROFINET status data
Short-Circuit Response Threshold 0.7 to 1.3 A; up to 2.6 A with I/O redundancy
Wire-Break Test Current 0.7 mA; doubled with I/O redundancy
Inductive Shutdown-Voltage Limitation L+ minus 37 to 41 V
Maximum Resistive Load Current 0.5 A per channel
Maximum Lamp Load 5 W
Load Resistance Range 48 Ω to 12 kΩ
Typical Resistive-Load Delay 50 µs from 0 to 1; 100 µs from 1 to 0
Maximum Switching Frequency 2 Hz with inductive load; 10 Hz with lamp load
Module Output Current Derating 8 A to 50 °C, 5.5 A at 60 °C and 3 A at 70 °C for horizontal installation
Maximum Cable Length 1000 m shielded; 600 m unshielded
Frequently Asked Questions

Which terminal block should I use with 6DL1132-6BH00-0EH1?

Use type H1 for standard operation or type M1 when a redundant output pair is required.

Can 6DL1132-6BH00-0EH1 control a load redundantly?

Yes, two compatible modules can provide redundant load control through the specified M1 terminal arrangement.

What current may one 6DL1132-6BH00-0EH1 channel switch?

Each output can switch up to 0.5 ampere within the module total-current and temperature limits.

How does 6DL1132-6BH00-0EH1 detect an open circuit?

A small test current is used for channel-level wire-break monitoring.

Which faults can 6DL1132-6BH00-0EH1 diagnose per channel?

The module detects wire breaks and short circuits to M or L+ on individual channels.

How should temperature derating be applied to 6DL1132-6BH00-0EH1?

Limit the combined output current according to the mounting orientation and highest cabinet temperature.

What configuration must be copied when exchanging 6DL1132-6BH00-0EH1?

Copy the channel parameters, substitute behavior, diagnostic enables, redundancy assignment and terminal mapping.

Compatibility & Ordering Notes
Before ordering 6DL1132-6BH00-0EH1: confirm the H1 or M1 terminal block, channel load currents, module current derating, redundancy pairing, diagnostic settings and SPPA-T3000 project version.

Compatibility Checklist

  • Select terminal-block type M1 only when the engineered station uses I/O redundancy.
  • Calculate the total output current at the maximum expected cabinet temperature.
  • Match every channel address, diagnostic option and field terminal before commissioning.
Hot Selling Models
5SY7101-7
RT24
ABB TA5105-4DOT 1SAP187000R0002
DCC08M02
SMT-8M-A-PO-24V-E-0.3-M12
SYJA12-01F
BES00P7 BES516-324-G-E5-C-S49
CES-A-BLN-U2-103450
T0-1-102/EA/SVB
ABB S203P S 203 P C3 2CDS283001R0034
2.1p-21 522121
F524.800FA3C
3RT1023-3BB40 3RH1921-1HA22
CPE18-3/2-PRS-3/8-2
524.800CA3C

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.