Siemens SIMATIC S7-400 FM 458 Application Module 6DD1607-0AA0
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
SIEMENS · SIMATIC S7-400
6DD1607-0AA0 SIMATIC S7-400 FM 458 Application Module
The FM 458 is a freely configurable application module for sophisticated high-dynamic control tasks in a SIMATIC S7-400 station, with fast RISC processing, local memory and expansion-module support.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DD1607-0AA0 |
| Product Type | FM 458 high-performance application module |
| Core Function | Runs graphically configured high-dynamic open-loop and closed-loop control tasks |
| Application or Compatible Series | SIMATIC S7-400 stations with compatible FM 458 expansion hardware |
Exact Identification
Match 6DD1607-0AA0 character by character and confirm the complete SIMATIC S7-400 FM 458 Application Module designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The FM 458 is a freely configurable application module for sophisticated high-dynamic control tasks in a SIMATIC S7-400 station, with fast RISC processing, local memory and expansion-module support.
A 128 MHz 64-bit RISC floating-point processor supports 0.1 ms minimum and 0.5 ms typical cycle times. Eight megabytes of DRAM and 256 KB of buffered SRAM support program execution, diagnostics, tracing and retained process data. Up to two EXM 438, EXM 438-1 or EXM 448 expansion modules can be coupled through the internal LE bus.
Key Functions
High-Dynamic Control Processing
A 128 MHz 64-bit RISC floating-point processor supports 0.1 ms minimum and 0.5 ms typical cycle times.
Buffered Application Memory
Eight megabytes of DRAM and 256 KB of buffered SRAM support program execution, diagnostics, tracing and retained process data.
Fast Process Expansion
Up to two EXM 438, EXM 438-1 or EXM 448 expansion modules can be coupled through the internal LE bus.
Official Specifications
| Processor Clock | 128 MHz |
|---|---|
| Processor Architecture | 64-bit RISC floating-point |
| Minimum Cycle Time | 0.1 ms |
| Typical Cycle Time | 0.5 ms |
| DRAM | 8 MB |
| Buffered SRAM | 256 KB |
| Supported Program Memories | MC 521 or MC 500 |
| Serial Service Interface | RS-232 with DUST1 at 19.2 kBd |
| Digital Inputs | 8 |
| Nominal Digital-Input Voltage | 24 V |
| Permissible Input-Voltage Range | -1 to +33 V |
| Signal-Zero Input Range | -1 to +6 V |
| Signal-One Input Range | +13.5 to +33 V |
| Typical Signal-One Input Current | 3 mA |
| Maximum Input Delay per Channel | 100 µs |
| Status LEDs | 8 |
| Maximum Expansion Modules | 2 |
| Dimensions | 25 x 290 x 210 mm |
| Weight | 0.92 kg |
Frequently Asked Questions
Which control tasks suit 6DD1607-0AA0?
The module is intended for demanding drive, tension, position, winder, synchronous and other high-dynamic control applications.
How quickly can 6DD1607-0AA0 execute a configured control cycle?
The minimum cycle time is 0.1 milliseconds, with 0.5 milliseconds identified as typical.
How many expansion modules can be connected to 6DD1607-0AA0?
Up to two compatible EXM 438, EXM 438-1 or EXM 448 modules can be combined with the application module.
Which program-memory modules can be used with 6DD1607-0AA0?
The supported removable program memories are MC 521 and MC 500.
How can a service computer connect to 6DD1607-0AA0?
Use the RS-232 service interface with the DUST1 protocol at 19.2 kBd and the specified connection cable.
What are the digital-input voltage limits for 6DD1607-0AA0?
The permissible input range is -1 to +33 volts, with a 24-volt nominal level.
What must be preserved before replacing 6DD1607-0AA0?
Save the CFC configuration, program memory, task cycle settings, expansion layout, diagnostics and all interface parameters.
Compatibility & Ordering Notes
Compatibility Checklist
- Install the module as a passive node in a compatible SIMATIC S7-400 station with adequate power capacity.
- Use only supported combinations of EXM 438, EXM 438-1 and EXM 448 expansion modules.
- Back up the full CFC application, memory-module contents and interface configuration before replacement.