Siemens 6AG1522-1BL01-7AB0 SIPLUS S7-1500 DQ 32x24VDC/0.5A HF Output Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use the 6ES7522-1BL01-0AB0 base-module electrical configuration for this SIPLUS variant.
- Calculate each group current against orientation and ambient temperature.
- Retain the supplied covers on unused interfaces for the specified environmental resistance.
- Allow the assembly to reach a suitable dry condition before commissioning.
SIEMENS SIPLUS S7-1500
6AG1522-1BL01-7AB0 SIPLUS S7-1500 DQ 32x24VDC/0.5A HF Output Module
Combine 32 digital output channels with a conformally coated SIPLUS assembly for extended-temperature installations and channel-level diagnostics.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6AG1522-1BL01-7AB0 |
| Product Type | Conformally coated digital output module |
| Core Function | Switch field loads in demanding environments |
| Application | S7-1500 industrial automation |
Coated electronics
The SIPLUS assembly is based on the DQ 32x24VDC/0.5A HF module with added conformal coating.
Grouped load circuits
Four groups of eight outputs support independent load-circuit planning.
Channel diagnostics
Output diagnostics and configurable substitute values support station maintenance.
Product Overview
6AG1522-1BL01-7AB0 is a SIPLUS digital output module based on the SIMATIC S7-1500 6ES7522-1BL01-0AB0. It adds conformal coating and extended environmental capability to the 32-channel High Feature output design.
The outputs provide 24 V DC switching at 0.5 A per channel, with single-channel diagnostics and substitute values; permissible group loading must be reduced as required by temperature and installation orientation.
Key Functions
Operate coated electronics in extended conditions
The SIPLUS version supports horizontal operation from −40 to +70 °C within its specified environmental and loading limits.
Switch four groups of DC loads
Thirty-two current-sourcing transistor outputs are arranged in groups of eight with up to 4 A per group under the applicable base-module conditions.
Diagnose output and supply faults
Channel diagnostics, supply monitoring and configurable substitute values help the controller respond to field faults.
Official Specifications
| Output Configuration | 32 current-sourcing transistor channels in groups of 8 |
|---|---|
| Rated Output Voltage and Current | 24 V DC; 0.5 A per channel |
| Maximum Group Current | 4 A subject to temperature and mounting derating |
| Additional Derating Above 60 °C | Maximum aggregate current 2 A per group |
| Horizontal Operating Temperature | −40 to +70 °C with applicable derating |
| Vertical Operating Temperature | −40 to +40 °C |
| Maximum Installation Altitude | 5000 m with altitude-dependent temperature reduction |
| Altitude Temperature Derating | Maximum temperature reduced by 10 K at 2000 to 3500 m and by 20 K at 3500 to 5000 m |
| Humidity Test Limit | 100% relative humidity including condensation or frost; no commissioning while bedewed |
| Protective Coating | EN 61086 Class 2; EN 60664-3 Type 1 protection |
| Permitted Load Resistance | 48 Ω to 12 kΩ |
| Maximum Lamp Load | 5 W per output |
| Minimum ON-State Output Voltage | L+ minus 0.8 V |
| Maximum OFF-State Residual Current | 0.5 mA |
| Maximum Resistive-Load Switching Delay | 100 µs OFF to ON; 500 µs ON to OFF |
| Maximum Switching Frequencies | 100 Hz resistive; 0.5 Hz inductive DC13; 10 Hz lamp loads |
| Output Fault Detection | Supply monitoring, wire-break and short-circuit diagnostics |
| Chemical Resistance, Stationary Systems | EN 60721-3-3 Class 3C4 at relative humidity below 75%, including EN 60068-2-52 severity 3 salt spray |
Frequently Asked Questions
What distinguishes 6AG1522-1BL01-7AB0 from its standard S7-1500 base module?
The SIPLUS assembly adds conformal coating and extended environmental capability to the 6ES7522-1BL01-0AB0 output design.
Does 6AG1522-1BL01-7AB0 support Grouped load circuits for mobile equipment?
Yes, horizontal operation extends to 70 °C when the applicable load derating is observed.
How much output current can each group of 6AG1522-1BL01-7AB0 carry above 60 °C?
The aggregate current is limited to 2 A per group above 60 °C.
Does vertical mounting permit the same temperature limit for 6AG1522-1BL01-7AB0?
No, the vertical operating-temperature range is −40 to +40 °C.
Can 6AG1522-1BL01-7AB0 be commissioned while moisture is condensed on the assembly?
No, commissioning in a bedewed state is excluded even though the humidity test conditions include condensation and frost.
How should I derate the operating temperature of 6AG1522-1BL01-7AB0 at 4000 m altitude?
Reduce the maximum ambient temperature by 20 K for installation altitudes above 3500 m up to 5000 m.
Which field faults can 6AG1522-1BL01-7AB0 diagnose?
The High Feature output design provides supply monitoring together with wire-break and short-circuit diagnostics.