siemens 3rm1002 1aa04 sirius 3rm1 0 4 2 a direct motor starter-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 3RM1002-1AA04 SIRIUS 3RM1 0.4–2 A Direct Motor Starter

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIRIUS 3RM1

3RM1002-1AA04 SIRIUS 3RM1 0.4–2 A Direct Motor Starter

A narrow hybrid direct starter with electronic overload protection, 24 V DC control and screw terminals.

At a Glance

Brand Siemens
Model 3RM1002-1AA04
Product Type Direct-on-line motor starter
Core Function Motor switching and overload protection
Application Small three-phase motor feeders

Adjustable electronic protection

The current-dependent overload release is adjustable from 0.4 A to 2 A.

Hybrid direct switching

Three hybrid-switched poles start a motor in one direction.

Hardwired control and indication

The starter uses 24 V DC control signals and provides electronic run indication plus an auxiliary changeover contact.

Product Overview

3RM1002-1AA04 combines direct motor starting with an adjustable electronic overload release.

Its hybrid switching circuit handles three main poles in a 22.5 mm-wide housing, with a status output and auxiliary changeover contact for machine control.

Ordering focus: Match motor current, feeder short-circuit protection, control voltage and installation clearances.
Key Functions

Adjustable electronic protection

The current-dependent overload release is adjustable from 0.4 A to 2 A.

Hybrid direct switching

Three hybrid-switched poles start a motor in one direction.

Hardwired control and indication

The starter uses 24 V DC control signals and provides electronic run indication plus an auxiliary changeover contact.

Official Specifications
Main operating voltage 48–500 V AC; 50/60 Hz
Overload-current setting 0.4–2 A
Rated main-circuit current 2 A at 400 V
Motor power at 400 V, 50 Hz 0.09–0.75 kW
Maximum starting current 16 A
Main switching circuit 3 poles with hybrid switching contacts
Control supply 24 V DC nominal; 19.2–30 V range
Digital control-input current 11 mA at signal 1; 1 mA at signal 0
Electronic signaling output 24 V DC, 15 mA
Auxiliary contact 1 changeover; maximum 3 A at AC-15/230 V or 1 A at DC-13/24 V
Switching delays 60–90 ms for both switch-on and switch-off
Maximum switching frequency 1 operation per second
Terminal arrangement Screw terminals for main and control circuits
Maximum unshielded motor cable 100 m
Protection IP20 on the front; finger-safe
Operating ambient −25 to +60 °C
Dimensions 22.5 × 100 × 141.6 mm (W × H × D)
Net weight 0.274 kg
Frequently Asked Questions

Can 3RM1002-1AA04 reverse the direction of a motor?

This direct-on-line starter provides one-direction starting and does not provide reverse starting.

Can the overload setting of 3RM1002-1AA04 be adjusted for a 1 A motor?

The adjustable overload-release range covers motor currents from 0.4 A to 2 A.

Does 3RM1002-1AA04 replace the feeder short-circuit protective device?

The starter does not provide short-circuit protection.

Can I use 3RM1002-1AA04 as a safety-rated emergency-stop device?

This version is not suitable for safety-related switching.

How much top and bottom clearance does 3RM1002-1AA04 need in a row?

Allow 50 mm above and 50 mm below the starter.

What main-circuit conductor size can I terminate on 3RM1002-1AA04?

The main contacts accept solid or stranded conductors from 0.5 mm² to 4 mm².

Does 3RM1002-1AA04 connect directly to PROFINET or AS-Interface?

The starter uses hardwired control and has no bus-communication function.

Compatibility & Ordering Notes
Before ordering 3RM1002-1AA04: Match motor current, feeder short-circuit protection, control voltage and installation clearances.

Before installation

  • Provide coordinated feeder short-circuit protection separately.
  • Set electronic overload protection to suit the connected motor and application.
  • Use the specified DC control supply and observe the absence of reverse-polarity protection.
  • Maintain the required clearances and account for derating with alternative mounting positions.
Hot Selling Models
CR4-1/XCR41
ZDU4/4AN 7904290000
3RT2027-1BB40
ADN-25-80-IPA
ADN-40-75-KP-APA
181BB500A000061
EWLR008ZMST
IQ40-40NPSKC0K
35B036
PSR-SCP-24DC/FSP/1X1/1X2
3003347
235-02Z-M20
RT/57325/M/15
KD485
CVI2 8307 S070768