- Overview
- Hot Selling Models
- Recommended Products
Overview
- Provide coordinated feeder short-circuit protection separately.
- Set electronic overload protection to suit the connected motor and application.
- Use the specified DC control supply and observe the absence of reverse-polarity protection.
- Maintain the required clearances and account for derating with alternative mounting positions.
3RM1002-1AA04 SIRIUS 3RM1 0.4–2 A Direct Motor Starter
A narrow hybrid direct starter with electronic overload protection, 24 V DC control and screw terminals.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RM1002-1AA04 |
| Product Type | Direct-on-line motor starter |
| Core Function | Motor switching and overload protection |
| Application | Small three-phase motor feeders |
Adjustable electronic protection
The current-dependent overload release is adjustable from 0.4 A to 2 A.
Hybrid direct switching
Three hybrid-switched poles start a motor in one direction.
Hardwired control and indication
The starter uses 24 V DC control signals and provides electronic run indication plus an auxiliary changeover contact.
Product Overview
3RM1002-1AA04 combines direct motor starting with an adjustable electronic overload release.
Its hybrid switching circuit handles three main poles in a 22.5 mm-wide housing, with a status output and auxiliary changeover contact for machine control.
Key Functions
Adjustable electronic protection
The current-dependent overload release is adjustable from 0.4 A to 2 A.
Hybrid direct switching
Three hybrid-switched poles start a motor in one direction.
Hardwired control and indication
The starter uses 24 V DC control signals and provides electronic run indication plus an auxiliary changeover contact.
Official Specifications
| Main operating voltage | 48–500 V AC; 50/60 Hz |
|---|---|
| Overload-current setting | 0.4–2 A |
| Rated main-circuit current | 2 A at 400 V |
| Motor power at 400 V, 50 Hz | 0.09–0.75 kW |
| Maximum starting current | 16 A |
| Main switching circuit | 3 poles with hybrid switching contacts |
| Control supply | 24 V DC nominal; 19.2–30 V range |
| Digital control-input current | 11 mA at signal 1; 1 mA at signal 0 |
| Electronic signaling output | 24 V DC, 15 mA |
| Auxiliary contact | 1 changeover; maximum 3 A at AC-15/230 V or 1 A at DC-13/24 V |
| Switching delays | 60–90 ms for both switch-on and switch-off |
| Maximum switching frequency | 1 operation per second |
| Terminal arrangement | Screw terminals for main and control circuits |
| Maximum unshielded motor cable | 100 m |
| Protection | IP20 on the front; finger-safe |
| Operating ambient | −25 to +60 °C |
| Dimensions | 22.5 × 100 × 141.6 mm (W × H × D) |
| Net weight | 0.274 kg |
Frequently Asked Questions
Can 3RM1002-1AA04 reverse the direction of a motor?
This direct-on-line starter provides one-direction starting and does not provide reverse starting.
Can the overload setting of 3RM1002-1AA04 be adjusted for a 1 A motor?
The adjustable overload-release range covers motor currents from 0.4 A to 2 A.
Does 3RM1002-1AA04 replace the feeder short-circuit protective device?
The starter does not provide short-circuit protection.
Can I use 3RM1002-1AA04 as a safety-rated emergency-stop device?
This version is not suitable for safety-related switching.
How much top and bottom clearance does 3RM1002-1AA04 need in a row?
Allow 50 mm above and 50 mm below the starter.
What main-circuit conductor size can I terminate on 3RM1002-1AA04?
The main contacts accept solid or stranded conductors from 0.5 mm² to 4 mm².
Does 3RM1002-1AA04 connect directly to PROFINET or AS-Interface?
The starter uses hardwired control and has no bus-communication function.