- Confirm the motor full-load current falls inside the 1.4 to 2 A range.
- Use a compatible ET 200S reversing-starter terminal module.
- Provide 24 V DC control power within 20.4 to 28.8 V DC.
- Reserve one input byte and one output byte in the station.
- Maintain a direction-change interval greater than 200 ms in the control program.
Siemens · SIMATIC ET 200S
3RK1301-1BB00-1AA2 RS1-X Reversing Starter 1.4–2 A
Siemens 3RK1301-1BB00-1AA2 is the SIMATIC ET 200S RS1-X standard expandable reversing motor starter with a 1.4 to 2 A setting range, 0.75 kW AC-3 rating at 400 V and a brake-control expansion interface.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RK1301-1BB00-1AA2 |
| Product Type | RS1-X Standard Reversing Motor Starter |
| Core Function | Provides electromechanical forward/reverse motor switching with integrated protection |
| Application or Compatible Series | SIMATIC ET 200S distributed I/O systems |
Motor Rating Match
Use only for a motor whose full-load current lies within the 1.4 to 2 A adjustment range.
Terminal-Module Installation
Plug the starter onto a compatible ET 200S reversing-starter terminal module.
Brake Expansion Provision
Add a compatible brake-control module through the expansion interface when required.
Product Overview
Siemens 3RK1301-1BB00-1AA2 is the SIMATIC ET 200S RS1-X standard expandable reversing motor starter with a 1.4 to 2 A setting range, 0.75 kW AC-3 rating at 400 V and a brake-control expansion interface.
Electromechanical contactors provide clockwise and counter-clockwise switching with mechanical interlocking. A circuit breaker with bimetal overload release supplies overload and short-circuit protection. Communication passes through the backplane bus in PROFIBUS DP or PROFINET ET 200S stations.
Key Functions
Bidirectional Motor Control
Electromechanical contactors provide clockwise and counter-clockwise switching with mechanical interlocking.
Integrated Motor Protection
A circuit breaker with bimetal overload release supplies overload and short-circuit protection.
ET 200S Station Integration
Communication passes through the backplane bus in PROFIBUS DP or PROFINET ET 200S stations.
Official Specifications
| Adjustable Overload-Release Range | 1.4 to 2 A |
|---|---|
| AC-3 Rating at 400 V | 2 A; 0.75 kW |
| Main-Circuit Operating Voltage | Rated 200 to 400 V; operating range 200 to 440 V AC at 50 Hz |
| Rated Operating Frequency | 50/60 Hz with ±10% tolerance |
| Control and Supply Voltage | 24 V DC; permissible range 20.4 to 28.8 V DC |
| Power Loss at Rated Current | 10 W hot-state total; 3.33 W per pole; typical no-load share 4.12 W |
| Rated Insulation Voltage | 500 V |
| Rated Impulse Withstand Voltage | 6 kV |
| Pollution Degree | Degree 3 at 400 V; degree 2 at 500 V according to IEC 60664 |
| Short-Circuit Breaking Capacity | 50 kA at 400 V |
| Maximum Operating Frequency | 750 operations per hour |
| Main-Contact Mechanical Life | Typically 100,000 operating cycles |
| Coordination Type | Type 2 |
| EMC Burst and Surge Immunity | 2 kV burst; 2 kV conductor-to-earth surge; 1 kV conductor-to-conductor surge |
| Safety Reliability Values | B10: 1,000,000 operations; T1 proof-test interval and service life: 20 years |
| Front Protection | IP20 and finger-safe |
| Process-Image Address Space | 1 input byte and 1 output byte |
| Dimensions | 90 × 265 × 120 mm |
| Operating and Storage Conditions | Operation 0 to 60 °C; storage and transport −40 to +70 °C; altitude up to 2,000 m |
| Net Weight | 1.211 kg |
Frequently Asked Questions
What motor rating is suitable for 3RK1301-1BB00-1AA2 at 400 V?
It is rated for an AC-3 motor load of 0.75 kW and 2 A at 400 V.
How is motor overload protection adjusted on 3RK1301-1BB00-1AA2?
Set the current-dependent bimetal overload release within its 1.4 to 2 A adjustment range.
How long should the direction-change interval be for 3RK1301-1BB00-1AA2?
Maintain an interval greater than 200 ms when changing between clockwise and counter-clockwise operation.
Which mounting arrangement is required for 3RK1301-1BB00-1AA2?
Plug the starter onto a compatible ET 200S reversing-starter terminal module.
Does 3RK1301-1BB00-1AA2 connect directly to PROFIBUS DP or PROFINET?
Communication passes through the ET 200S backplane bus within a PROFIBUS DP or PROFINET station.
Can I add a brake-control module to 3RK1301-1BB00-1AA2?
A compatible xB-series brake-control module can be connected through the expansion interface.
What site limits should I check before installing 3RK1301-1BB00-1AA2?
Keep the operating temperature between 0 and 60 °C and the installation altitude at or below 2,000 m.