Siemens 3RH6911-1DA11 SIRIUS 1 NO + 1 NC Side-Mounted Auxiliary Contact Block
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Match the lateral accessory interface of the 3RT6 or 3RH6 host.
- Retain the required one-NO and one-NC control paths.
- Select the load by voltage and duty category.
- Use 0.8–1.2 N·m on the M3 auxiliary terminals.
3RH6911-1DA11 SIRIUS 1 NO + 1 NC Side-Mounted Auxiliary Contact Block
A side-mounted, screw-terminal auxiliary block with one normally open and one normally closed contact.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RH6911-1DA11 |
| Product Type | Auxiliary contact block |
| Core Function | Contactor state signaling |
| Application | Compatible 3RT6 and 3RH6 devices |
Lateral fitting
The -DA design mounts at the side of a compatible contactor or contactor relay.
Two contact functions
One NO and one NC element provide complementary auxiliary control paths.
Specified terminal tightening
M3 screws use a PZ2 screwdriver and 0.8–1.2 N·m tightening torque.
Product Overview
3RH6911-1DA11 adds a normally open and a normally closed auxiliary contact through a lateral mounting arrangement on compatible SIRIUS devices.
The standard-switching block uses screw terminals and provides defined AC general-purpose and DC pilot-duty ratings for control-circuit selection.
Key Functions
Add auxiliary state paths
One NO contact and one NC contact provide the switching elements used by the connected control circuit.
Use the side accessory position
The -DA mounting pattern fits laterally to the compatible host rather than occupying its front accessory position.
Terminate the auxiliary circuit
M3 screw terminals provide the field connection with 0.8–1.2 N·m controlled tightening.
Official Specifications
| Contact arrangement | 1 NO + 1 NC |
|---|---|
| Connection technology | M3 screw terminals |
| Mounting arrangement | Lateral attachment |
| Switching action | Standard switching |
| AC general-purpose rating | 10 A at 240 V AC |
| DC pilot-duty rating | 6 A at 24 V DC |
| Pilot-duty designation | A600 / Q600 |
| Terminal tightening torque | 0.8–1.2 N·m |
| Terminal screwdriver | PZ2, blade diameter 5–6 mm |
| Product safety standards | UL 60947-1 and UL 60947-5-1; CSA C22.2 No. 60947-1 and No. 60947-5-1 |
Frequently Asked Questions
Can I fit 3RH6911-1DA11 in the front accessory position instead of at the side?
No, the -DA design is a laterally mounted auxiliary contact block.
Does 3RH6911-1DA11 provide both a closing and an opening auxiliary contact?
Yes, it has one normally open contact and one normally closed contact.
Is 3RH6911-1DA11 a make-before-break contact block?
No, the A switching-function code identifies standard switching rather than make-before-break action.
What torque should I use on the M3 terminals of 3RH6911-1DA11?
Tighten the auxiliary terminal screws to 0.8–1.2 N·m using a PZ2 screwdriver.
Can I use the 10 A rating of 3RH6911-1DA11 for a 240 V AC general-purpose circuit?
Yes, the AC general-purpose rating is 10 A at 240 V AC.
Does the 6 A at 24 V DC rating of 3RH6911-1DA11 describe a coil supply?
No, it is the auxiliary contact pilot-duty rating for a 24 V DC control circuit.
What must be done before attaching or removing 3RH6911-1DA11?
Turn off and lock out all power supplying the host device before working on the auxiliary block.