Schneider Electric 140ACI04000 Modicon Quantum 16-Channel Analog Current Input Module
Manufacturer: Schneider Electric
Condition: Brand New
Lead Time: In Stock
Origin: France
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use current-output transmitters within the supported ranges.
- Match 4–20 mA scaling to the existing application.
- Allow 360 mA in the backplane current budget.
- Distinguish module power from the field transmitter supply requirements.
140ACI04000 Modicon Quantum 16-Channel Analog Current Input Module
The Quantum analog input module acquires 16 current signals with selectable 0–20 mA, 0–25 mA and 4–20 mA ranges and uses 17 input words.
At a Glance
| Brand | Schneider Electric |
|---|---|
| Model | 140ACI04000 |
| Product Type | Analog input module |
| Core Function | Acquisition of process current signals |
| Application | Modicon Quantum automation platforms |
Sixteen analog channels
Differential current inputs connect process transmitters.
Selectable scaling
The 4–20 mA range supports 0–16000 or 0–4095 counts.
Quantum backplane
The standard-format module draws 360 mA from the bus.
Product Overview
140ACI04000 is a Modicon Quantum current-input module for acquiring 16 analog process signals. It supports three unipolar current ranges and selectable scaling for 4–20 mA applications.
The module uses 17 input words and provides local indicators for bus activity, external faults, channel enable status and channel faults, supporting commissioning of multi-channel transmitter installations.
Key Functions
Multi-range current acquisition
The inputs accept 0–20 mA, 0–25 mA or 4–20 mA process signals for integration of current-output transmitters.
Application scaling
Input representation supports 0–20000 counts for 0–20 mA, 0–25000 for 0–25 mA and two scaling choices for 4–20 mA.
Channel fault visibility
The 4–20 mA mode includes broken-wire detection, with dedicated channel indicators and an external-fault LED for local troubleshooting.
Official Specifications
| Input channels | 16 differential current inputs |
|---|---|
| Input ranges | 0–20 mA, 0–25 mA and 4–20 mA |
| Digital input representation | 0–20000 counts at 0–20 mA; 0–25000 at 0–25 mA; 0–16000 or 0–4095 at 4–20 mA |
| Address allocation | 17 input words |
| Maximum voltage between channels | 30 V DC |
| Bus current requirement | 360 mA |
| Maximum dissipated power | 5 W |
| External module power supply | Not required |
| Online configuration modification | Available |
| Net weight | 0.300 kg |
Frequently Asked Questions
Can I connect a 0–10 V transmitter directly to 140ACI04000?
The module accepts current ranges of 0–20 mA, 0–25 mA and 4–20 mA rather than a 0–10 V voltage range.
How many input words should I reserve for 140ACI04000?
The complete module requires 17 input words.
Can I retain a 0–4095 scale for 4–20 mA signals on 140ACI04000?
The 4–20 mA range supports both 0–4095 and 0–16000 count representations.
Does 140ACI04000 detect a disconnected 4–20 mA loop?
Broken-wire detection is provided for the 4–20 mA range.
Does 140ACI04000 need an external supply for its module electronics?
The module electronics use the Quantum bus supply and do not require a separate external module power supply.
How quickly does 140ACI04000 update two-wire or four-wire inputs?
The update time is 15 ms for two-wire or four-wire operation.
Which LEDs on 140ACI04000 help isolate a faulty transmitter channel?
The front panel includes sixteen green channel-enabled indicators and sixteen red channel-fault indicators alongside bus-active and external-fault LEDs.