S200-IR8 S200IR RTD Input Unit

  • Overview
  • Specifications
  • Functional Description
  • Applications
  • Features
  • Troubleshooting
  • FAQ
  • Recommended Products
Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

S200-IR8 S200IR8

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Value

Model

S200-IR8 S200IR8

Product Type

RTD Input Unit

Number of Inputs

8

Galvanic Isolation

Yes

Status Indicator

Bi-colour LED (green/red, OK)

Resolution

16-bit

Input Range

1–433 Ω

Overvoltage Capability

±35 V DC, 25 V AC continuous, 250 V peak transient

Accuracy

≤0.05% FSR (typ. 0.01% enhanced mode) @ 25°C

Internal Bus Current Consumption

≤20 mA

Filter

Programmable

Noise Rejection

60 dB @ 60 Hz (A/D filter 15 Hz)

Calibration

Programmable

Common Mode Rejection

120 dB @ 60 Hz, 100 dB @ 50 Hz

System Throughput

28–325 ms/channel (normal), 56–650 ms/channel (enhanced)

Open-wire Detection

Upscale out-of-range indication

Open-wire Detection Time

~1 s

RTD Excitation Current

718 µA

Offset Drift (Temp)

≤1.5 mΩ/°C

Gain Drift (Temp)

20 ppm/°C (normal), 10 ppm/°C (enhanced)

Operating Temperature

0 °C to +55 °C

Storage Temperature

-40 °C to +85 °C

Humidity (Operating)

5–95% non-condensing

Humidity (Storage)

5–80% non-condensing

Supported Sensors

Pt (100/200/500 Ω), Ni (100/120/200/500 Ω), Cu (10 Ω)

Sensor Temperature Range

Pt: -200 to +870 °C; Ni: -60 to +250 °C; Cu: -200 to +260 °C

Unit Identity Code

1B01 (hex)

Backplane Key Code

3

External Power Supply

24 V DC (19.2–31.2 V DC)

Supply Current

60 mA @ 24 V DC

Power Dissipation

3 W max

Weight

0.085 kg (net), 0.180 kg (gross)

Dimensions

94 x 46 x 53 mm

Certifications

CSA Class I Div 2 (T5), European Ex Zone 2 Group IIC

Functional Description

The S200-IR8 S200IR8 is a RTD Input Unit. The 8 analog input signals are connected to the unit via the screw terminal on the terminal base unit.

The inputs are as a group of 8 galvanically isolated from the serial bus by optocouplers. It is possible to deselect unused channels to improve system throughput. Periodic user calibration is supported.

Power for the internal logic is provided via an external power supply.

Applications

Thermal power plants: Monitoring bearing temperature, boiler tube wall temperature, and cooling water system.

Pharmaceutical manufacturing plants: Used in processes requiring extremely high temperature accuracy, such as fermenters and sterilizers.

Food and beverage plants: Monitoring pasteurization lines, cold chain logistics in cold storage, and reactor temperatures.

Petrochemical plants: Multi-point temperature monitoring of distillation columns and heat tracing monitoring of oil pipelines.

Cement processing plants: Rotary kiln bearing protection and thermal parameter acquisition for waste heat power generation systems.

Features

Replacement under system power

CE and UL approvement

Software configurable function

Mechanical coding for safe replacement

Safety function on outputs in remote configuration

Variety of termination options

The same I/O units in central andremote configurations

Compatible with I/O 200C

Troubleshooting

System is running and the adapter active.

The LED OK indicates the general status of 200-IR8 and the status in relation to communication with the application in the controller.

Symptom1

Steady red: Indicating a critical fault

Measure:

Replace the unit.

Symptom2

Flashing red: Indicating a noncritical fault (such as open sensor, input out of range, etc.)

Measure:

1. Check cabling and connectors.

2. Check that correct type is selected in the

hardware configuration.

3. Replace the unit.

Symptom3

Flashing green: Indicating that the unit is functional but not configured

Measure:

1. Start the program to configure the unit.

2. Check the program.

3. Replace the unit.

FAQ

Q1: Can the S200-IR8 S200IR8 connect to a thermocouple (TC)?
No. It is designed for resistance sensors (RTDs). For thermocouple connections, please use the S200-IT8 module.

Q2: Why is my Pt100 reading a few degrees higher than the actual value on the S200-IR8 S200IR8?
Please check if you are using a 2-wire connection. If so, the module cannot compensate for cable resistance; we recommend using a 3-wire or 4-wire connection.

Q3: Can the S200-IR8 S200IR8 module automatically identify the sensor type?
No. You must manually configure the sensor specification (e.g., Pt100 or Ni100) for each channel in the control software (such as Control Builder).

Q4: Should a channel on the S200-IR8 S200IR8 be shorted if it is not in use?
Short-circuiting is usually not required, but we recommend setting it to "disabled" in the software configuration to avoid disconnection alarms.

Q5: Can I directly unplug the S200-IR8 S200IR8 module while the system is running?
Yes, as long as it is installed on a hot-swappable terminal block, but the eight temperature points corresponding to the module will lose monitoring during the unplugging process.