Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

IMCPM02

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Parameter

Value

Model

IMCPM02

Description

Communication Port Module

Dimension

3.5x31x17.6 cm

Weight

0.38 kg

Dimensions (Detailed)

76.2 mm; 279.4 mm; 355.6 mm

Weight (Detailed)

0.68 kg (1.5 lb)

Current Consumption

0.81 A max, 750 mA typical at +5 VDC

Power Dissipation

4.1 W max, 3.8 W typical

Microprocessor

32-bit processor (16-bit external bus) at 16 MHz

Memory

128 kB ROM; 256 kB RAM

Serial Ports

1 isolated RS-232-C, up to 19.2 kbaud

EMI/RFI Recommendation

Keep cabinet doors closed; maintain at least 2 m distance from communication equipment

Operating Temperature

0°C to +70°C (32°F to 158°F)

Relative Humidity

5% to 90% up to 55°C; 5% to 40% at 70°C (non-condensing)

Atmospheric Pressure

Sea level to 3 km (1.86 mi)

Certification

CSA certified for process control equipment in nonhazardous locations

Description

The IMCPM02 module is a microprocessor based single slot wide INFI 90 interface module that provides a local (within the PCU) means for system configuration, tuning and diagnostics. It interfaces the CTT terminal and EWS station to the Controlway through faceplate connectors. The IMCPM02 module enables the user to configure, tune and monitor the master modules and their function blocks. It can communicate with master modules in the PCUs that use either module bus or Controlway. The IMCPM02 module has one two-color (red/green) LED and eight red LEDs for module status indication. There are two eight pole dipswitches that set the Controlway or module bus address, select baud rate and enable diagnostic testing. A reset switch is available through the faceplate. The IMCPM02 faceplate has two connectors. A DB-25 connector for the EWS port and a round 5-pin connector for the CTT terminal. A jumper array selects DTE, DCE or loopback operating mode for the EWS port. The IMCPM02 module occupies a single slot in a standard INFI 90 module mounting unit (MMU). An optional termination unit can be connected through a cable for permanent mounting.

Applications

Power and Energy: This is the most classic application scenario for the INFI 90 system. It's used in boiler control, turbine control, and data acquisition systems for coal-fired/gas-fired power plants.

Oil and Gas: Applied to refineries, oil and gas extraction stations, and long-distance pipeline control, handling complex PID regulation and safety interlocks.

Chemicals and Pharmaceuticals: In fine chemical, basic chemical, and biopharmaceutical plants, it's responsible for reactor control, formula management, and batch production process monitoring.

Paper and Pulp: Used in high-precision continuous production lines such as paper machine drive control and pulp concentration control.

Metallurgy and Mining: Plays a role in sintering, ironmaking, and steelmaking control systems in steel plants, as well as in mineral processing processes in mines.

Cement and Building Materials: For example, in cement rotary kiln and mill control systems, enabling plant-wide automated monitoring through a central control room.

GENERAL HANDLING

1. Examine the hardware immediately to verify that it has not been damaged in transit.

2. Notify the nearest Bailey Controls sales office of any such damage.

3. File a claim for any damage with the transportation company that handled the shipment.

4. Use the original packing material and container to store the hardware.

5. Store the hardware in an environment of good air quality,

free from temperature and moisture extremes.

OPERATION

When functioning as a CTT interface, the IMCPM02 module accepts a module bus message from the CTT terminal and sends the message to the destination module through the Controlway or module bus. The module reply is then received by the IMCPM02 module and returned to the CTT interface. When functioning as an EWS interface, the IMCPM02 module receives EWS commands, forwards them to the destination module, and sends the reply to the EWS station over the RS-232 channel. The CTT interface and EWS interface may both be used at the same time.

REPLACEMENT

1. Turn the two concentric screws ½ turn either way to release them.

2. Grasp the screws and slide the module out.

3. Set switches SW1 and SW2 on the replacement to match the settings of the CPM module recently removed.

4. Verify jumpers J5 and J6, and J11 and J12.

5. Hold the module by the faceplate and slide it into the slot; push until the rear edges are firmly seated in the backplane connectors.

6. Turn the two concentric screws ½ turn clockwise either way to lock the module into the module mounting unit.

FAQ

Q: What is the IMCPM02?

A: It is a Communication Port Module.

Q: What about your delivery time of IMCPM02?

A: Generally 1-3 days after receiving your payment. The specific delivery time depends on the type and quantity of the order.

Q: How long is the warranty period of IMCPM02?

A: We offer a standard one-year warranty for all new and original products.

Q: Do you offer any discounts?

A: Yes! For discounts on IMCPM02, please contact John for the best offer.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.