Siemens 6ES7138-4CB11-0AB0 SIMATIC ET 200S PM-E AC/DC Power Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Choose a listed TM-P15S, TM-P15C or TM-P15N base with the required AUX1 arrangement.
- Set Voltage type to AC or DC to match the actual load supply.
- Apply the appropriate AC or DC current limit at the cabinet temperature.
- Use the specified replaceable fast fuse and external branch-circuit protection.
- Reserve the required input/output bytes for status and option handling.
- Enable missing-voltage and fuse diagnostics where the application needs those events.
6ES7138-4CB11-0AB0 SIMATIC ET 200S PM-E AC/DC Power Module
A 15 mm power module for DC and AC load groups, with selectable voltage type, a replaceable supplementary fuse and diagnostics for missing load voltage or fuse failure.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7138-4CB11-0AB0 |
| Product Type | PM-E power module |
| Core Function | Feeds and monitors a load-potential group |
| Application | ET 200S stations with suitable TM-P bases |
AC or DC selection
The voltage-type parameter must match the connected supply.
Thermal current limits
Permissible group current depends on supply type and ambient temperature.
Fuse and supply monitoring
Separate indicators identify the load supply and fuse condition.
Product Overview
6ES7138-4CB11-0AB0 supplies an ET 200S voltage group through a suitable TM-P terminal module.
It combines configurable load-voltage and fuse diagnostics with a replaceable fast fuse, while external branch-circuit protection remains required on the supply lines.
Key Functions
Configure the supply type
The voltage-type parameter selects DC or AC and defaults to DC, so replacing an older AC installation requires the corresponding hardware setting.
Report a lost supply or blown fuse
The two diagnostic events can be enabled separately, with SF, PWR and FSG LEDs supporting fault identification.
Limit the supplied group by its load
The combined load of the modules in the voltage group must stay within the current capacity for the supply type and ambient temperature.
Official Specifications
| DC Load-Voltage Range | 24–56.7 V DC |
|---|---|
| AC Load-Voltage Ratings | 24–48 V AC, 120 V AC or 230 V AC |
| DC Group-Current Limits | 10 A up to 30 °C; 9 A up to 40 °C; 7 A up to 60 °C |
| AC Group-Current Limits | 8 A up to 30 °C; 7 A up to 40 °C; 5 A up to 60 °C |
| Supplementary Fuse | Replaceable 5 × 20 mm, 250 V, 10 A fast fuse to IEC 127-2/1 |
| Insulation Test Voltage | 1,500 V AC |
| Maximum Backplane Current | 9.5 mA |
| Maximum No-Load Supply Current | 9 mA from L1/L+ |
| Maximum Power Dissipation | 5 W |
| Parameter Length | 3 bytes |
| Status-Byte Address Allocation | 1 input byte |
| Option-Handling Address Allocation | 8 input bytes and 8 output bytes |
| Combined Status and Option Handling | 9 input bytes and 9 output bytes; ninth output byte not relevant |
| Diagnostic Indicators | Red SF; green PWR; green FSG |
| Overall Dimensions | 15 × 81 × 52 mm (W × H × D) |
| Approximate Weight | 34 g |
Frequently Asked Questions
What must I change when using 6ES7138-4CB11-0AB0 to replace 6ES7138-4CB00-0AB0 on AC power?
Create the corresponding hardware configuration and set the voltage-type parameter to AC.
Can I rely on the fuse inside 6ES7138-4CB11-0AB0 as the only supply-line protection?
The internal fuse is supplementary and the load-circuit supply lines still require suitable external overcurrent protection.
Which replacement fuse is specified for 6ES7138-4CB11-0AB0?
Use the 5 × 20 mm, 250 V, 10 A fast fuse with article number 6ES7193-4KA10-0AA0.
How much current can 6ES7138-4CB11-0AB0 feed on 230 V AC at 60 °C?
The permitted AC group current is 5 A at temperatures up to 60 °C.
Can I enable missing-voltage and blown-fuse alarms independently on 6ES7138-4CB11-0AB0?
The two diagnostic events have separate enable parameters and both are disabled by default.
Which terminals carry the load supply to 6ES7138-4CB11-0AB0?
Terminals 2 and 6 carry L+/L1, while terminals 3 and 7 carry M/N.
How should I choose the TM-P base below 6ES7138-4CB11-0AB0?
Choose a listed TM-P15 terminal base with the required screw, spring or Fast Connect method and the appropriate AUX1 routing.