siemens 6es7138 4cb11 0ab0 simatic et 200s pm e ac dc power module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7138-4CB11-0AB0 SIMATIC ET 200S PM-E AC/DC Power Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC ET 200S

6ES7138-4CB11-0AB0 SIMATIC ET 200S PM-E AC/DC Power Module

A 15 mm power module for DC and AC load groups, with selectable voltage type, a replaceable supplementary fuse and diagnostics for missing load voltage or fuse failure.

At a Glance

Brand Siemens
Model 6ES7138-4CB11-0AB0
Product Type PM-E power module
Core Function Feeds and monitors a load-potential group
Application ET 200S stations with suitable TM-P bases

AC or DC selection

The voltage-type parameter must match the connected supply.

Thermal current limits

Permissible group current depends on supply type and ambient temperature.

Fuse and supply monitoring

Separate indicators identify the load supply and fuse condition.

Product Overview

6ES7138-4CB11-0AB0 supplies an ET 200S voltage group through a suitable TM-P terminal module.

It combines configurable load-voltage and fuse diagnostics with a replaceable fast fuse, while external branch-circuit protection remains required on the supply lines.

Ordering focus: Set the voltage type to AC for an AC replacement installation, and size the whole voltage-group current to the applicable temperature limit.
Key Functions

Configure the supply type

The voltage-type parameter selects DC or AC and defaults to DC, so replacing an older AC installation requires the corresponding hardware setting.

Report a lost supply or blown fuse

The two diagnostic events can be enabled separately, with SF, PWR and FSG LEDs supporting fault identification.

Limit the supplied group by its load

The combined load of the modules in the voltage group must stay within the current capacity for the supply type and ambient temperature.

Official Specifications
DC Load-Voltage Range 24–56.7 V DC
AC Load-Voltage Ratings 24–48 V AC, 120 V AC or 230 V AC
DC Group-Current Limits 10 A up to 30 °C; 9 A up to 40 °C; 7 A up to 60 °C
AC Group-Current Limits 8 A up to 30 °C; 7 A up to 40 °C; 5 A up to 60 °C
Supplementary Fuse Replaceable 5 × 20 mm, 250 V, 10 A fast fuse to IEC 127-2/1
Insulation Test Voltage 1,500 V AC
Maximum Backplane Current 9.5 mA
Maximum No-Load Supply Current 9 mA from L1/L+
Maximum Power Dissipation 5 W
Parameter Length 3 bytes
Status-Byte Address Allocation 1 input byte
Option-Handling Address Allocation 8 input bytes and 8 output bytes
Combined Status and Option Handling 9 input bytes and 9 output bytes; ninth output byte not relevant
Diagnostic Indicators Red SF; green PWR; green FSG
Overall Dimensions 15 × 81 × 52 mm (W × H × D)
Approximate Weight 34 g
Frequently Asked Questions

What must I change when using 6ES7138-4CB11-0AB0 to replace 6ES7138-4CB00-0AB0 on AC power?

Create the corresponding hardware configuration and set the voltage-type parameter to AC.

Can I rely on the fuse inside 6ES7138-4CB11-0AB0 as the only supply-line protection?

The internal fuse is supplementary and the load-circuit supply lines still require suitable external overcurrent protection.

Which replacement fuse is specified for 6ES7138-4CB11-0AB0?

Use the 5 × 20 mm, 250 V, 10 A fast fuse with article number 6ES7193-4KA10-0AA0.

How much current can 6ES7138-4CB11-0AB0 feed on 230 V AC at 60 °C?

The permitted AC group current is 5 A at temperatures up to 60 °C.

Can I enable missing-voltage and blown-fuse alarms independently on 6ES7138-4CB11-0AB0?

The two diagnostic events have separate enable parameters and both are disabled by default.

Which terminals carry the load supply to 6ES7138-4CB11-0AB0?

Terminals 2 and 6 carry L+/L1, while terminals 3 and 7 carry M/N.

How should I choose the TM-P base below 6ES7138-4CB11-0AB0?

Choose a listed TM-P15 terminal base with the required screw, spring or Fast Connect method and the appropriate AUX1 routing.

Compatibility & Ordering Notes
Before ordering 6ES7138-4CB11-0AB0: Match the connected AC or DC supply, the TM-P terminal base, the group-current derating and the external protective device.

Compatibility Checklist for 6ES7138-4CB11-0AB0

  • Choose a listed TM-P15S, TM-P15C or TM-P15N base with the required AUX1 arrangement.
  • Set Voltage type to AC or DC to match the actual load supply.
  • Apply the appropriate AC or DC current limit at the cabinet temperature.
  • Use the specified replaceable fast fuse and external branch-circuit protection.
  • Reserve the required input/output bytes for status and option handling.
  • Enable missing-voltage and fuse diagnostics where the application needs those events.
Hot Selling Models
2963763 PSR-SCP-24UC/ESA4/3X1/1X2/B
ADN2030APAS2
RF340R 6GT2801-2AB10
3NJ4915-2HB20
TR35520z
5SY41 MCB C4 5SY4104-7 5ST3010
P1DILEM
T0-4-8440/EZ
LC2K09015D7
S402M UCC6 2CCS572001R1064
5-745-96-002-7
249170
7999-88001-2330200
3TH2040-0BD4
6ES5464-8MD11

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.