- Overview
- Specifications
- Description
- Environment and certification
- Applications
- Features and benefits
- Diagnostics
- FAQ
- Recommended Products
Overview
Place of Origin: |
Sweden |
Brand Name: |
ABB |
Model Number: |
DI803 3BSE022362R1 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Product Name: |
Digital Input Module |
|
Model: |
DI803 3BSE022362R1 |
|
Signal Specification: |
230 V AC, 220 V DC |
|
Number of Channels: |
8 |
|
Signal Type: |
Current sinking |
|
HART Support: |
No |
|
SOE Support: |
No |
|
Redundancy: |
No |
|
High Integrity: |
No |
|
Intrinsic Safety: |
No |
|
Mechanics: |
S800L |
|
Width: |
86.1 mm (3.4”) |
|
Depth: |
58.5 mm (2.3”) |
|
Height: |
110 mm (4.33”) |
|
Weight: |
0.24 kg (0.53 lbs.) |
|
Input Voltage Range "0": |
0..50 V AC, 0..40 V DC |
|
Input Voltage Range "1": |
164..264 V AC, 175..275 V DC |
|
Input Impedance: |
30 kΩ (AC), 134 kΩ (DC) |
|
Isolation: |
Individually isolated channels |
|
Filter Times (digital, selectable): |
2, 4, 8, 16 ms |
|
Input Frequency Range: |
47..63 Hz |
|
Analog Filter On/Off Delay: |
5 / 28 ms |
|
Maximum Field Cable Length: |
200 m (219 yd) AC 100 pF/m, 600 m DC |
|
Rated Insulation Voltage: |
250 V |
|
Dielectric Test Voltage: |
2000 V AC |
|
Power Dissipation: |
Typ. 2.8 W |
|
Current Consumption +5V Modulebus: |
50 mA |
|
Current Consumption +24V Modulebus: |
0 |
|
Current Consumption +24V External: |
0 |
|
Supported Wire Size: |
Solid: 0.05-2.5 mm², 30-12 AWG; Stranded: 0.05-1.5 mm², 30-12 AWG |
|
Recommended Torque: |
0.5-0.6 Nm |
|
Stripping Length: |
6-7.5 mm (0.24-0.30 inch) |
Description
The DI803 3BSE022362R1 is an 8 channel 230 V a.c./d.c. digital input module for the S800 I/O. This module has 8 digital inputs. The a.c. input voltage range is 164 - 264 volt and the input current is 7.6 mA at 230 V a.c. The d.c. input range is 175 - 275 V and the input current is 1.6 mA at 220 V. The inputs are individually isolated. Every input channel consists of current limiting components, EMC protection components, input state indication LED and optical isolation barrier.
Environment and certification
|
CE Mark: |
Yes |
|
Electrical Safety: |
EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201 |
|
Hazardous Location: |
- |
|
Marine Certification: |
ABS, BV, DNV, LR |
|
Operating Temperature: |
0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C |
|
Storage Temperature: |
-40 to +70 °C (-40 to +158 °F) |
|
Pollution Degree: |
Degree 2, IEC 60664-1 |
|
Corrosion Protection: |
ISA-S71.04: G3 |
|
Relative Humidity: |
5 to 95 %, non-condensing |
|
Max Ambient Temperature: |
55 °C (131 °F), for vertical mounting 40 °C (104 °F) |
|
Protection Class: |
IP20 according to IEC 60529 |
|
Mechanical Operating Conditions: |
IEC/EN 61131-2 |
|
EMC: |
EN 61000-6-4 and EN 61000-6-2 |
|
Overvoltage Categories: |
Class I according to IEC 61140 (earth protected) |
|
Equipment Class: |
Class I according to IEC 61140 (earth protected) |
|
RoHS Compliance: |
EU RoHS, UAE RoHS, CN RoHS |
|
WEEE Compliance: |
DIRECTIVE/2012/19/EU |
Applications
Fine Chemical and Hazardous Materials Plants:
Used for monitoring the status of reactors and safety valves. Due to complete isolation between channels, even if a sensor is accidentally connected to high voltage or experiences a grounding fault, the entire I/O card will not burn out, ensuring the monitoring of other critical signals.
Power and Energy Plants (Substation Auxiliary Monitoring):
In switchyard environments filled with high-frequency electromagnetic interference, independent isolation groups effectively block common-mode interference, ensuring the authenticity of switch status feedback.
Semiconductor and Precision Electronics Plants:
Used in cleanroom control systems. Its high stability ensures 24/7 uninterrupted acquisition of environmental parameters (such as fan status and differential pressure alarms).
Features and benefits
8 channels for 230 V a.c./d.c. inputs with current sinking
Individually isolated channels
Voltage supervision of field input power
Input status indicators
Signal filtering
Process connection via detachable connectors
Diagnostics
Front LED’s: S(tatus) (run or fault), Channel 1-16 ("0" or "1")
Supervision: Process voltage supervision on channel 8
Status indication of supervision : Module Error, Module Warning, Channel Error
FAQ
Q1: What are the main differences between DI803 3BSE022362R1 and DI801?
A: DI801 has 16 channels with common ground, while DI803 has 8 channels with independent isolation. DI803 offers higher security but lower channel density.
Q2: Does DI803 3BSE022362R1 support Sequential Event Recording (SOE)?
A: No. For 1ms-level recall, DI830 should be used.
Q3: Does DI803 3BSE022362R1 support hot-swapping?
A: Yes. Modules can be directly removed and replaced while the system is running without disconnecting the bus or power supply.
Q4: Why are the LEDs not turning on even though I've connected a signal of DI803 3BSE022362R1?
A: Check if the common terminal for that channel is properly connected. Each DI803 3BSE022362R1 requires an independent power supply loop.