siemens 6es7132 4bf00 0aa0 simatic et 200s 8do dc24v 0 5a output module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7132-4BF00-0AA0 SIMATIC ET 200S 8DO DC24V/0.5A Output Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC ET 200S

6ES7132-4BF00-0AA0 SIMATIC ET 200S 8DO DC24V/0.5A Output Module

Eight 24 V DC outputs in a 15 mm electronic module, with 0.5 A rated channel current, channel short-circuit protection and a 4 A module total.

At a Glance

Brand Siemens
Model 6ES7132-4BF00-0AA0
Product Type Digital output electronic module
Core Function Switching DC actuators and indicator loads
Application ET 200S distributed I/O stations

Actuator channels

Eight outputs drive solenoid valves, DC contactors and indicator lights.

Load selection

Resistive, inductive and lamp loads have different switching-frequency limits.

Terminal planning

Two-wire actuator circuits may require additional M terminals or potential-distribution modules.

Product Overview

6ES7132-4BF00-0AA0 provides eight electronic outputs for switching DC field loads in an ET 200S station, with 0.5 A rated current at each output and a maximum total of 4 A per module.

The module supports isochronous operation and provides a green status indicator for each channel, while actuator selection must account for switching frequency, lamp power and off-state leakage.

Ordering focus: Check the installed ET 200S interface revision and firmware, select a supported 15 mm terminal base, and provide enough return terminals for all connected loads.
Key Functions

Switch several actuator types

The outputs operate solenoid valves, DC contactors and indicator lamps, with electronic short-circuit protection on each channel.

Match switching rate to the load

The permitted switching frequency is 100 Hz for resistive loads, 2 Hz for inductive loads and 10 Hz for lamp loads.

Coordinate load returns and supply switching

Provide separate M connection points for two-wire loads and account for an approximately 50 μs high pulse when a mechanical contact applies the load supply.

Official Specifications
Output Channels 8
Rated Load Supply 24 V DC from the power module
Output Current Limits 0.5 A rated per channel; 7 mA–0.6 A permissible range; 4 A total per module
ON-State Output Voltage At least L+ minus 1 V
Maximum OFF-State Residual Current 0.3 mA
Resistive-Load Output Delays 0 to 1: 300 μs maximum; 1 to 0: 600 μs maximum
Load Resistance Range 48 Ω–3.4 kΩ
Maximum Lamp Load 5 W
Switching Frequency by Load 100 Hz resistive; 2 Hz inductive; 10 Hz lamp
Short-Circuit Protection Electronic per channel; typical response threshold 1.5 A
Maximum No-Load Supply Current 5 mA per channel
Typical Power Dissipation 1.5 W
Output Address Allocation 1 byte
Parameter Data Length 3 bytes
Maximum Cable Length 600 m unshielded; 1000 m shielded
Isolation Arrangement Channels isolated from backplane bus; no channel-to-channel isolation
Permissible Inter-Circuit Potential Difference 75 V DC or 60 V AC
Insulation Test Voltage 500 V DC
Module Width and Approximate Weight 15 mm; 40 g
Diagnostics and Status Green LED per output; no diagnostic functions
Frequently Asked Questions

Can I parallel two channels of 6ES7132-4BF00-0AA0 to power a larger actuator?

Parallel outputs may be used for redundant load control within the module, but they must not be used to increase output power.

Why might a high-speed counter detect a pulse when 6ES7132-4BF00-0AA0 receives load power?

Applying the 24 V DC load supply through a mechanical contact can produce an approximately 50 μs high signal at the outputs.

Do two-wire actuators connected to 6ES7132-4BF00-0AA0 need extra return terminals?

Additional M terminals are required when the selected terminal-base arrangement does not provide enough return connections for the loads.

How often can 6ES7132-4BF00-0AA0 switch a solenoid compared with a resistive load?

The switching-frequency limit is 2 Hz for inductive loads and 100 Hz for resistive loads.

Will 6ES7132-4BF00-0AA0 provide an electronic fault message for a failed output?

The module has channel status LEDs but does not provide diagnostic functions.

What lamp power can I connect to a channel of 6ES7132-4BF00-0AA0?

The maximum lamp load is 5 W per output.

Which interface firmware is needed for 6ES7132-4BF00-0AA0 with IM151-1 HIGH FEATURE?

The supported IM151-1 HIGH FEATURE arrangement starts at 6ES7151-1BA01-0AB0 with firmware V2.1.3.

Compatibility & Ordering Notes
Before ordering 6ES7132-4BF00-0AA0: Match the output current and load type to the actuator, allow for the 4 A module total, and select the terminal base and interface revision for the installed ET 200S station.

Compatibility Checklist for 6ES7132-4BF00-0AA0

  • Supported PROFIBUS interfaces include IM151-1 STANDARD from 6ES7151-1AA03-0AB0 and IM151-1 FO STANDARD from 6ES7151-1AB02-0AB0.
  • For IM151-1 HIGH FEATURE, use 6ES7151-1BA01-0AB0 or higher with firmware V2.1.3 or higher.
  • Supported PN interfaces start at 6ES7151-3AA20-0AB0, 6ES7151-3BA20-0AB0 or 6ES7151-3BB21-0AB0 with firmware V4.0.1 or higher.
  • Choose a supported TM-E15C, TM-E15S or TM-E15N terminal module and provide the required M return connections.
  • Do not parallel outputs to increase current capacity, and consider the supply-on pulse in pulse-sensitive circuits.
Hot Selling Models
Efector200 E21166
BJ6-016S
PLC-BSC-24DC/21
DSN-25-100-P
1608640000
NZ1HB-528-M
LC1-D179FA65
3RV1421-4AA10
3RV2411-1KA15