Overview
SIRIUS 3RM1 • Fail-Safe Motor Starting

3RM1107-1AA04 SIRIUS 3RM1 Fail-Safe Direct Motor Starter

Hybrid direct starter for 0.55–3 kW motors at 400 V, with a 1.6–7 A setting range, 24 V DC control and screw terminals.

At a Glance

Brand Siemens
Model 3RM1107-1AA04
Product Type Fail-safe direct motor starter
Core Function Motor starting with electronic overload protection and safety-related shutdown
Application Hardwired control of three-phase motors

Hybrid direct switching

Starts the motor directly through a three-pole hybrid power circuit; reversing operation is not provided.

Electronic motor protection

The overload setting covers 1.6–7 A to match the connected motor current.

Safety-related shutdown

Safety-related switching off opens the load circuit with stop category 0; the complete safety function depends on the configured application.

Product Overview

3RM1107-1AA04 combines direct motor switching, solid-state overload protection and safety-related disconnection in a compact SIRIUS 3RM1 starter.

The hybrid three-pole power circuit is designed for direct starting, while current derating, external short-circuit protection and mounting clearances must be considered in the motor feeder.

Ordering focus: Match the motor current and 400 V power rating, provide the required short-circuit protection and apply temperature-dependent current derating.
Key Functions

Hybrid direct switching

Starts the motor directly through a three-pole hybrid power circuit; reversing operation is not provided.

Electronic motor protection

The overload setting covers 1.6–7 A to match the connected motor current.

Safety-related shutdown

Safety-related switching off opens the load circuit with stop category 0; the complete safety function depends on the configured application.

Official Specifications
Rated main-circuit voltage 48–500 V AC
Main-circuit frequency 50 or 60 Hz
Adjustable overload-current range 1.6–7 A
Motor power at 400 V, 50 Hz 0.55–3 kW, three-phase
Rated operational current at 400 V 7 A
Current derating by ambient temperature 7 A at 40 °C; 6.1 A at 50 °C; 5.2 A at 55 °C; 4.6 A at 60 °C
Maximum starting current 56 A
Control supply 24 V DC nominal; permissible range 19.2–30 V DC
Control current 13 mA standby; 57 mA during operation
Digital control input 24 V DC; typical signal-1 current 8 mA
Auxiliary contact 1 changeover contact; maximum 3 A AC-15 at 230 V or 1 A DC-13 at 24 V
Safety capability SIL 3; Category 4 and PL e for the specified safety function
Safe state and stop category Load circuit open; stop category 0
Terminal arrangement Screw terminals for main and control circuits
Maximum unshielded motor cable 100 m
Mounting method Screw fixing or snap-on mounting to a 35 mm DIN rail
Required vertical clearance 50 mm above and below
Operating temperature −25 to +60 °C with current derating
Dimensions (W × H × D) 22.5 × 100 × 141.6 mm
Net weight 0.275 kg
Frequently Asked Questions

Can 3RM1107-1AA04 reverse a motor?

This direct starter does not provide reversing operation.

Does 3RM1107-1AA04 replace the feeder short-circuit protective device?

The starter has no short-circuit protection function, so the feeder requires an appropriately selected protective device.

Can 3RM1107-1AA04 carry 7 A continuously at 60 °C?

The operational-current rating falls to 4.6 A at 60 °C.

How much space is required above and below 3RM1107-1AA04?

Maintain 50 mm clearance above and below the starter.

Does fail-safe operation of 3RM1107-1AA04 require PROFIsafe communication?

The starter has no PROFIsafe or bus-communication function and uses its hardwired control circuits.

Which control voltage is required for 3RM1107-1AA04?

Use a nominal 24 V DC control supply within the permitted 19.2–30 V DC range.

What contact is available for external indication on 3RM1107-1AA04?

One auxiliary changeover contact is rated up to 3 A AC-15 at 230 V or 1 A DC-13 at 24 V.

Compatibility & Ordering Notes
Before ordering 3RM1107-1AA04: Match the motor current and 400 V power rating, provide the required short-circuit protection and apply temperature-dependent current derating.

Before installation

  • Set the overload-current response to the motor requirements within the 1.6–7 A adjustment range.
  • Provide coordinated feeder short-circuit protection because the starter does not perform that function.
  • Apply current derating and maintain the required mounting clearances.
  • Validate the complete hardwired safety circuit for the required shutdown function.
Hot Selling Models
200B-16DI/16DO 133-0BL00-0XB0 193-0CB10-0XA0
3TF3400-0B
FDC72-1
Allen-Bradley SLC500 1746-OB16
CP-E16-M
3VL9400-4PJ00
5SX2 350-7
192T3210 TCB 26-40
SMTO-1-PS-K-LED-24C
283-901
3SE5122-0CH01
6ES7194-4AF00-0AA0 6ES7154-4AB10-0AB0
ES28/38
ABB 1SDA066665R1
FAZ-C16/2-NA

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.