Overview
- Configure the exact Standard interface and station address in the PROFIBUS master project.
- Keep process data within 128 input bytes and 128 output bytes.
- Observe the 63-module and 2 m station limits and fit the terminating module.
- Select the PROFIBUS cable length and termination for the chosen transmission rate.
6ES7151-1AA03-0AB0 SIMATIC ET 200S IM151-1 Standard Interface
PROFIBUS DP interface with 128 input bytes, 128 output bytes and support for up to 63 ET 200S station modules.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7151-1AA03-0AB0 |
| Product Type | PROFIBUS DP interface module |
| Core Function | Connection of ET 200S station modules to PROFIBUS DP |
| Application | Distributed machine IO and motor starter stations |
ET 200S station connection
Up to 63 power, electronic or motor starter modules can be connected within a maximum station width of 2 m.
PROFIBUS DP exchange
RS485 communication supports rates up to 12 Mbit/s with SYNC, FREEZE and direct slave-to-slave data exchange.
Local service indicators
Red BF and SF LEDs and a green 24 V ON indicator help identify network, station and supply conditions.
Product Overview
6ES7151-1AA03-0AB0 connects an ET 200S distributed IO station to a PROFIBUS DP controller through a 9-pin Sub-D interface.
The station can include power, electronic and motor starter modules within its module-count, width and process-data limits, with local LEDs for bus, group and supply status.
Key Functions
ET 200S station connection
Up to 63 power, electronic or motor starter modules can be connected within a maximum station width of 2 m.
PROFIBUS DP exchange
RS485 communication supports rates up to 12 Mbit/s with SYNC, FREEZE and direct slave-to-slave data exchange.
Local service indicators
Red BF and SF LEDs and a green 24 V ON indicator help identify network, station and supply conditions.
Official Specifications
| PROFIBUS data rate | 9.6 kbit/s to 12 Mbit/s |
|---|---|
| Physical interface | RS485; 9-pin Sub-D socket |
| Input process data | 128 bytes |
| Output process data | 128 bytes |
| Maximum station modules | 63 power, electronic or motor starter modules |
| Maximum station width | 2 m |
| Maximum supply current | 200 mA from 1L+ |
| Typical power loss | 3.3 W |
| Voltage failure bridging | 20 ms |
| PROFIBUS functions | SYNC, FREEZE and direct slave-to-slave exchange |
| Isochronous operation | Not supported |
| Alarm function | Not supported |
| Diagnostics | Supported; BF, SF and 24 V ON LEDs |
| Interface isolation | PROFIBUS DP isolated from electronics |
| Isolation test voltage | 500 V DC |
| Dimensions (W × H × D) | 45 × 119.5 × 75 mm |
| Weight | Approximately 150 g |
Frequently Asked Questions
Can 6ES7151-1AA03-0AB0 connect an ET 200S station to PROFINET?
This interface uses PROFIBUS DP over RS485 and does not support PROFINET IO.
Can 6ES7151-1AA03-0AB0 address more than 128 input bytes?
The input and output process-data areas are each limited to 128 bytes.
How wide may a station using 6ES7151-1AA03-0AB0 be?
The connected station may contain up to 63 modules within a maximum width of 2 m.
Does 6ES7151-1AA03-0AB0 support synchronous distributed IO timing?
Isochronous mode is not supported by this Standard interface.
Can 6ES7151-1AA03-0AB0 participate in direct slave-to-slave communication?
PROFIBUS direct data exchange is supported together with SYNC and FREEZE services.
What should be checked when the BF LED on 6ES7151-1AA03-0AB0 is red?
Check the PROFIBUS cabling, station address and master configuration before investigating the local station modules.
Which station-end component is needed with 6ES7151-1AA03-0AB0?
The ET 200S station requires its terminating module at the end of the module assembly.