ADLEE POWERTRONIC AS

AS2-115 AS Series 1.5kW Single-Phase Input Inverter

A 1.5 kW AS-series inverter with a single-phase 220 V input, three-phase 220 V motor output, a 7 A output rating and adjustable acceleration and deceleration.

At a Glance

Brand Adlee Powertronic
Model AS2-115
Product Type General-purpose motor inverter
Core Function Adjusting AC motor speed
Application Industrial variable-speed motor systems

Single-phase power input

The supply connects to L1 and L2 for the single-phase input arrangement.

Three-phase motor output

U, V and W connect to the motor rather than the incoming AC supply.

Local frequency control

The keypad and front-panel frequency knob provide the basic frequency-setting methods.

Product Overview

AS2-115 controls a compatible AC motor from the AS-series single-phase input arrangement, with a rated motor capacity of 1.5 kW for a four-pole motor.

The sine-wave PWM output, selectable frequency reference and adjustable ramps provide the main operating controls, with forced-air cooling for the drive assembly.

Ordering focus: Match the single-phase supply, motor voltage and current, provide vertical ventilated mounting, and set the operating frequency and ramps for the driven machine.
Key Functions

Generate the motor supply from the single-phase input

The inverter converts the specified single-phase AC feed into a three-phase 220 V motor supply with a rated 7 A output.

Set the operating speed and ramps

The standard output-frequency range is 0.5–400 Hz, and acceleration and deceleration times can be set from 0.1 to 6000 seconds.

Manage braking and heat removal

Regenerative discharge braking and forced-air cooling form part of the drive arrangement, with a 150% overload rating for one minute.

Official Specifications
Input Supply Single-phase 220 V AC ±10%
Input Frequency 50–60 Hz ±10%
Output Supply Three-phase 220 V AC
Applicable Four-Pole Motor 1.5 kW
Rated Output Current 7 A
Output Capacity 2.7 kVA
Standard Output-Frequency Range 0.5–400 Hz
Control Method Sine-wave pulse-width modulation
Braking Method Regenerative discharge braking
Overload Capacity 150% of rated current for 1 minute
Acceleration and Deceleration Setting Range 0.1–6000 seconds each
Basic Frequency-Setting Methods Digital keypad or frequency knob
Display LED digital display
Cooling Method Forced-air cooling
Installation Ambient Temperature −10 to +45 °C
Net Weight 1.3 kg
Frequently Asked Questions

Which incoming terminals should I use for the single-phase supply on AS2-115?

Connect the single-phase supply to L1 and L2.

Can I connect the incoming AC supply to U, V and W on AS2-115?

U, V and W are motor-output terminals and must not be connected to the incoming AC supply.

What motor capacity and current rating apply to AS2-115?

The drive is rated for a 1.5 kW four-pole motor with a 7 A output current.

How long can the acceleration and deceleration ramps on AS2-115 be set?

Each ramp can be set from 0.1 to 6000 seconds.

How should I orient AS2-115 inside a cabinet?

Install the unit vertically with ventilation space and keep the installation ambient temperature between −10 and +45 °C.

Does AS2-115 use natural convection alone for cooling?

This power size uses forced-air cooling.

When can a technician begin inspecting AS2-115 after power-off?

Inspection should begin only after the main supply is isolated and the CHARGE indicator has gone out.

Compatibility & Ordering Notes
Before ordering AS2-115: Select the single-phase 220 V AS-series drive for the compatible motor, using both the 1.5 kW motor capacity and 7 A output limit in the selection.

Compatibility Checklist for AS2-115

  • Use the specified single-phase input supply on L1 and L2.
  • Connect the motor to U, V and W and provide the protective-earth connection.
  • Keep the motor current and operating speed within the drive and machine limits.
  • Mount vertically on nonflammable material with suitable ventilation space.
  • Set the frequency reference, acceleration and deceleration before commissioning.
  • Isolate power and wait for the CHARGE indicator to extinguish before inspection.
Hot Selling Models
IFS28A IFB3007-BPKG/M/US/3D
FAZ-C16/1
NEFCM12G80.3M12G5LK
3RU1116-1CB1
FR14GG69V16
3RT1017-2AP02
MINI-PS- 12- 24DC/24DC/1
CXSM10-30
MC 17-10
50/30(30)
ADN-25-10-A-P-A
AES1235
3RA2933-2BB1
SFK0215008
516-423.10.X 516-423-10-X

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.