- Overview
- Quick Detail
- Description
- Applications
- Specifications
- Competitive Advantage
- Recommended Products
Overview
Place of Origin: |
USA |
Brand Name: |
Bently Nevada |
Model Number: |
3300/01 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Quick Detail
|
System Function |
Centralized rack interface, operator interaction, buffered signals on front panel |
|
Optional Interface |
Optional serial interface capability |
|
Contact Closure Inputs |
Rack Inhibit, Alarm Reset, Trip Multiply |
|
Power Supply |
Accepts regulated DC voltage from rack power supply |
|
Nominal Power Consumption |
2 W; 3.6 W with serial interface option |
|
Input Impedance |
10 kΩ |
|
Output Impedance |
100 Ω |
|
Operating Temperature |
0°C to +65°C (+32°F to +149°F) |
|
Storage Temperature |
-40°C to +85°C (-40°F to +185°F) |
|
Relative Humidity |
Up to 95% non-condensing |
|
Serial Interface Address Setting |
8 switches, up to 256 addresses |
|
Serial Interface Baud Rate |
Configurable, up to 9600 baud |
|
Dimension: |
2.5x12.8x4cm |
|
Weight: |
0.26 kg |
Description
The 3300/01 System Monitor is designed for centralized rack control and operator interaction in industrial automation monitoring systems. The 3300/01 System Monitor integrates buffered transducer signals directly on the front panel, eliminating the need for external keypads or connector cards. With nominal power consumption of 2 W, or 3.6 W when equipped with the serial interface option, the 3300/01 System Monitor operates efficiently within standard rack power supplies.
The 3300/01 System Monitor supports contact closure inputs for Rack Inhibit, Alarm Reset, and Trip Multiply through rear panel terminals, enabling direct control of protection functions. Input impedance is 10 kΩ and output impedance is 100 Ω, supporting accurate signal transmission within the rack. Operating temperature ranges from 0°C to +65°C, with storage from -40°C to +85°C and humidity up to 95% non-condensing.
With optional serial interface capability, the 3300/01 System Monitor provides configurable baud rates up to 9600, selectable CRC or BCC message checking, and up to 256 addresses via 8 switches, supporting Allen Bradley or Modicon protocol selection for automated machinery monitoring.
Applications
Adjust alarm setpoints with 8 bit to 12 bit internal conversion
The 3300/01 System Monitor converts 8 bit input data into a 12 bit internal value, allowing finer alarm adjustment steps directly from the front panel. With 10 kΩ input impedance and 100 Ω output impedance, the 3300/01 System Monitor maintains accurate signal transfer while operators modify alarm limits using the Up and Down controls.
Transmit rack data to PLC systems at up to 9600 baud
The 3300/01 System Monitor supports configurable baud rates up to 9600 and allows up to 256 device addresses via 8 hardware switches. This enables the 3300/01 System Monitor to communicate vibration and process values to Allen Bradley or Modicon PLC platforms using CRC or BCC message checking.
Provide buffered signal outputs for field diagnostics
The 3300/01 System Monitor delivers buffered transducer signals on the front panel, allowing technicians to connect test equipment without affecting rack circuits. With nominal power consumption of 2 W, or 3.6 W with serial interface installed, the 3300/01 System Monitor supports continuous monitoring in multi-slot racks.
Specifications
|
Message Checking |
CRC or BCC selectable (Allen Bradley supports CRC/BCC; Modicon supports CRC only) |
|
Parity and Stop Bit Selection |
Configurable via 2 switches |
|
Protocol Selection |
Allen Bradley or Modicon selectable by switch |
|
BCD Switch Option |
Binary Coded Decimal formatting available for Allen Bradley protocol |
|
Data Format |
8-bit value converted to 12-bit internal value; optional BCD conversion |
|
Front Panel Controls |
Up/Down alarm setpoint adjustment; Alarm Reset switch |
|
Rear Panel Connections |
Terminals for Rack Inhibit, Trip Multiply, Alarm Reset |
|
Rear Panel Ports |
2 receptacles for Communications Processor; 2 receptacles for Serial Interface |
Competitive Advantage
Reduce rack power load to 2 W to 3.6 W per module
The 3300/01 System Monitor operates at 2 W under standard configuration and 3.6 W with serial interface, enabling installation of multiple 3300/01 System Monitor units without exceeding rack power supply limits.
Support up to 256 communication addresses in one rack system
Using 8 address switches, the 3300/01 System Monitor allows 256 selectable nodes, enabling large distributed monitoring systems controlled by multiple 3300/01 System Monitor modules.
Operate within 0°C to +65°C and store at -40°C to +85°C
The 3300/01 System Monitor functions across industrial temperature ranges and withstands storage extremes, allowing deployment of the 3300/01 System Monitor in control rooms and field enclosures.
Select protocol and message verification through hardware switches
The 3300/01 System Monitor provides CRC or BCC checking and Allen Bradley or Modicon protocol selection via switch settings, enabling the 3300/01 System Monitor to connect directly to different PLC communication standards without firmware modification.