Overview
Place of Origin: |
Sweden |
Brand Name: |
ABB |
Model Number: |
TU921S 3KDE175111L9210 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Model |
TU921S 3KDE175111L9210 |
|
Type |
Redundant Termination Unit |
|
Signal type |
Redundant termination unit |
|
SOE |
N/A |
|
Redundancy |
No |
|
Intrinsic safety |
Yes |
|
Mechanics |
S900 |
|
Supported wire size |
0.5 - 2.5 mm² |
|
Width |
498 mm (19.6 in.) |
|
Depth |
147 mm (5.8 in.) |
|
Height |
274 mm (10.8 in.) |
|
Weight |
3.79 kg (8.35 lbs.) |
|
CE mark |
Yes |
|
Hazardous Location |
ATEX Zone 1 |
|
Corrosive atmosphere |
ISA-S71.04: G3 |
|
Climatic operating conditions |
Relative humidity max. 93 % ±3 % at 40 °C |
|
Max ambient temperature |
-20 °C to +60 °C |
|
RoHS compliance |
DIRECTIVE/2011/65/EU (EN 50581:2012) |
|
WEEE compliance |
DIRECTIVE/2012/19/EU |
|
WEEE category |
Small Equipment (No External Dimension More Than 50 cm) |
Description
The remote S900 I/O system can be installed in non-hazardous areas or directly in Zone 1 or Zone 2 hazardous area depending on the selected system variant. S900 I/O communicates with the control system level using the PROFIBUS DP standard. The I/O system can be installed directly in the field, therefore the costs for marshalling and wiring are reduced.
The system is sturdy, error-tolerant and easy to service. Integrated disconnection mechanisms allow replacement during operation, meaning that there is no need to interrupt the primary voltage in order to exchange the power supply units.
S900 I/O type S. For installation in hazardous area Zone 1. For connecting intrinsically safe field devices installed in Zone 2, Zone 1 or Zone 0.
TU921S 3KDE175111L9210 Redundant Termination Unit (TU16R-Ex), for 16 I/O-modules, redundant communication and power (Delivery includes CD910).
Applications
Features and benefits
ATEX Certification for installation in Zone 1
Redundancy (Power and Communication)
Hot Configuration in Run
Hot Swap functionallity
Extended Diagnostic
Excellent configuration and diagnostics via FDT/DTM
G3 – coating for all components
Simplified maintenance with auto-diagnostics
Termination unit for up to 16 I/O modules
Prepared for redundant system power and communication
Up to 4 terminals per channel
Preselection of fieldbus address
Prepared for certified field housing
Mounting in Zone 1, Zone 2 or safe area possible
FAQ
Q: In which explosion-proof areas can the TU921S 3KDE175111L9210 be installed?
A: It is ATEX certified and can be installed directly in Zone 1, Zone 2, or non-hazardous areas.
Q: What is the maximum number of field signals the TU921S 3KDE175111L9210 terminal unit can support?
A: It supports up to 16 I/O modules, with a maximum of 4 terminal blocks per channel. The exact number depends on the type of module inserted.
Q: Is it necessary to shut down the system when changing the power module of the TU921S 3KDE175111L9210?
A: No. It features an integrated power-off mechanism and hot-swappable functionality, allowing for the replacement of power or communication modules while the system is running.
Q: Is the TU921S 3KDE175111L9210 resistant to corrosive gases?
A: Yes. All components are standardly coated with G3 (compliant with ISA-S71.04), suitable for harsh industrial atmospheres.
Q: Are accessories included in the TU921S 3KDE175111L9210 package?
A: A CD910 accessory for identification or configuration is included in the standard delivery.