Siemens TX-I/O TXM1.6R 6 Relay Output Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Switzerland
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens TX-I/O TXM1.6R 6-Relay Output Module
TX-I/O module with six independently configurable volt-free changeover relay outputs for maintained, pulsed, multistage and three-position control functions.
At a Glance
| Brand / Manufacturer | Siemens |
|---|---|
| Model / Article Number | TXM1.6R |
| Product Type | Six-channel relay output module |
| Core Function | Switches six independently configurable volt-free relay outputs |
| Application / Compatible Series | Siemens TX-I/O / DESIGO building automation systems |
Maintained, pulsed, multistage and three-position control.
Adjacent points may use AC 250 V and SELV/PELV 24 V circuits.
Plug-in I/O module and terminal base permit replacement without rewiring.
Product Overview
TXM1.6R is officially identified by Siemens as TX-I/O relay output module with six individually configurable changeover contacts for building automation applications.
The complete article number TXM1.6R should be matched against the installed hardware, nameplate and official project documentation. Similar products can differ in electrical ratings, interfaces, connector design or approved system use.
Key Functions
Model-Specific Configuration
TXM1.6R: Six changeover relay outputs; TXM1.6R is the version without local manual override.
System Interface
TXM1.6R: Bus supply is 21.5 to 26 V DC and maximum module power consumption is 1.7 W.
Replacement Control
TXM1.6R: Contacts support AC 12 to 250 V up to 4 A resistive, or DC 12 to 30 V up to 3 A resistive.
Official Specifications
| Operating Voltage | 21.5 V DC to 26 V DC, SELV or PELV |
|---|---|
| Maximum Power Consumption | 1.7 W |
| AC Switching Voltage | 12 V AC to 250 V AC |
| AC Resistive Current, Maximum | 4 A |
| AC Inductive Current, Maximum | 3 A at cos φ ≥ 0.6 |
| DC Switching Voltage | 12 V DC to 30 V DC |
| DC Resistive Current, Maximum | 3 A at 30 V DC |
| Make Current | 20 A for 10 ms; 10 A for 1 s |
| Contact Life at 250 V AC | 8 million operations at 0.1 A; 2 million at 0.5 A; 0.2 million at 4 A |
| Insulation Test Level | 3,750 V AC between relay outputs and system electronics |
| External Fuse, Maximum | 10 A slow-blow |
| Circuit Breaker, Maximum | 13 A, characteristic B, C or D |
| Terminal Design | Cage-clamp terminals |
| Solid Conductor Range | 0.5 mm² to 4 mm² |
| Stranded Conductor Range | 0.5 mm² to 2.5 mm² without sleeves |
| Maximum Terminal Torque | 0.6 N·m |
| Operating Temperature | -5 °C to +50 °C |
| Storage and Transport Temperature | -25 °C to +70 °C |
| Relative Humidity | 5% to 95% |
| Protection Rating | IP30 front components; IP20 terminal base |
Frequently Asked Questions
Which building-automation applications are suitable for TXM1.6R?
It is designed for TX-I/O and DESIGO relay-switching functions such as maintained, pulsed, multistage and three-position control.
How can the six outputs of TXM1.6R be configured?
Each volt-free changeover output can be assigned independently to the supported relay control functions.
What AC and DC load ranges can TXM1.6R switch?
The contacts support 12 to 250 V AC and 12 to 30 V DC within the stated current limits.
May mixed voltage classes be wired on adjacent TXM1.6R points?
Adjacent points may use AC 250 V mains circuits and SELV/PELV 24 V circuits because the relay contacts are isolated and not interconnected.
In which orientation may TXM1.6R be mounted?
Any orientation is permitted when ventilation keeps the ambient temperature within -5 °C to +50 °C.
What must be retained when replacing the plug-in module of TXM1.6R?
Keep the address key in the terminal base; the plug-in module can then be replaced without rewiring the remaining I/O modules.
Which terminal protection should be provided for TXM1.6R?
Use no more than a 10 A slow-blow fuse or a 13 A type B, C or D circuit breaker for the incoming cable.
Compatibility & Ordering Notes
Compatibility Checklist for TXM1.6R
- Match the complete article number TXM1.6R without shortening the suffix.
- Confirm the installed TX-I/O family and hardware revision.
- Verify: Six changeover relay outputs; TXM1.6R is the version without local manual override.
- Confirm included connectors and accessories in the written quotation.