siemens sitrans p320 7mf03401dm015af2 z differential pressure transmitter-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SITRANS P320 7MF03401DM015AF2-Z Differential Pressure Transmitter

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SITRANS P320 · PRESSURE TRANSMITTER

7MF03401DM015AF2-Z SITRANS P320 Differential Pressure Transmitter

PN160 pressure transmitter for differential-pressure and flow measurement with a 60 mbar maximum span and 4–20 mA/HART communication.

At a Glance

Brand Siemens
Model 7MF03401DM015AF2-Z
Product Type SITRANS P320 pressure transmitter
Core Function Differential-pressure and flow measurement
Application or Compatible Series SITRANS P320/P420 process pressure systems

Exact Identification

Match the complete order code and every -Z option suffix.

Process Interface

PN160 oval flange with stainless-steel wetted parts.

Loop Integration

Coordinate the 4–20 mA/HART loop and local display.

Product Overview

Siemens 7MF03401DM015AF2-Z corresponds to order number 7MF0340-1DM01-5AF2-Z in the SITRANS P320 family, configured for differential-pressure and flow measurement at PN160.

Its silicone-oil measuring cell has a maximum span of 60 mbar (24.11 inH2O), while the 4–20 mA/HART output supports process-loop integration and device communication.

The transmitter uses 316L stainless-steel process connections and seal diaphragms, a die-cast aluminum dual-chamber housing, two M20 × 1.5 cable entries and a local display behind a glass-window lid.

Ordering focus: the -Z suffix requires the complete option combination to be matched with the installed span, process connection, enclosure, cable-entry and display configuration.
Key Functions

Low-Span Differential Measurement

The silicone-oil measuring cell covers differential-pressure and flow duties with a maximum span of 60 mbar.

4–20 mA/HART Communication

The analog loop carries the process value while HART enables parameterization and device communication.

PN160 Stainless-Steel Process Interface

The oval-flange arrangement combines 316L process connections and seal diaphragms with a 316/1.4408 process flange.

Dual-Chamber Local Interface

The die-cast aluminum enclosure separates the terminal and electronics areas and includes a display under a glass-window lid.

Official Specifications
Nominal Pressure PN160
Output Signal 4–20 mA with HART
Measuring Cell Fill Silicone oil
Maximum Measuring Span 60 mbar (24.11 inH2O)
Flange Form Oval flange
Fastening Thread M10 for PN160
Process Connection Material Stainless steel 316L / 1.4404
Seal Diaphragm Material Stainless steel 316L / 1.4404
Process Flange Material Stainless steel 316 / 1.4408
Housing Material Die-cast aluminum
Housing Design Dual-chamber enclosure
Explosion Protection Version Without Ex protection
Cable Entries 2 × M20 × 1.5
Local Display Included with glass-window lid
Frequently Asked Questions

Which process measurements suit 7MF03401DM015AF2-Z?

It is intended for differential-pressure and flow measurement within a PN160 process configuration.

What loop signal should engineers use with 7MF03401DM015AF2-Z?

Use a 4–20 mA loop with HART communication for the measured value, parameterization and diagnostics.

Which wetted materials are used in 7MF03401DM015AF2-Z?

The process connection and seal diaphragms use 316L/1.4404 stainless steel, while the PN160 process flange uses 316/1.4408 stainless steel.

How should 7MF03401DM015AF2-Z be mounted on the process flange?

Use the oval-flange arrangement with the specified M10 fastening thread for the PN160 configuration.

Does 7MF03401DM015AF2-Z include a local display?

The dual-chamber version includes a display beneath a glass-window lid.

What should be checked before wiring 7MF03401DM015AF2-Z?

Verify the two M20 × 1.5 cable entries, the 4–20 mA/HART loop requirements and the selected enclosure configuration.

What must be matched when replacing 7MF03401DM015AF2-Z?

Match the complete -Z option code, 60 mbar span, wetted materials, housing, display and process-connection configuration.

Compatibility & Ordering Notes
Before ordering 7MF03401DM015AF2-Z: confirm the complete Siemens order number with every -Z option code, the 60 mbar span, PN160 oval flange, M10 fastening, wetted materials, cable entries and display configuration.

Compatibility Checklist

  • Match the configured SITRANS P320 option suffixes rather than the base order number alone.
  • Verify the installed process pressure class, flange threads and wetted-material selection.
  • Record the HART loop setup, measuring range and cable-entry arrangement before removal.
Hot Selling Models
BN5983.53 0032155
DO479 3D0479.6 3D0 479.6
IB 00409460
CST34-V-1 101181429
WL24-2B430
GHR4410000VO
10BASE-T 2831028
IC+102
SK3321 607
3RT2016-2BB42
CDQSB25-75DC
LR2 D1316 023261 9-13A
Allen-Bradley 1492-FB2C30
SZ 2372.030
MN1H-5/3G-D-1-C

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop