Siemens SITRANS FUP1010 7ME35101CA000AA0 Portable Ultrasonic Flowmeter
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Confirm that the selected transducers cover the pipe outside diameter and liquid temperature.
- Check that the pipe wall and coupling location provide a clean, fully developed acoustic path.
- Select the required current, voltage, pulse or serial output before connecting external recording equipment.
SIEMENS SITRANS F US CLAMP-ON
Siemens SITRANS FUP1010 7ME35101CA000AA0 Portable Ultrasonic Flowmeter
Portable IP67 ultrasonic flow measurement for commissioning, verification and temporary clamp-on surveys without opening the pipe.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 7ME35101CA000AA0 |
| Product Type | Portable ultrasonic flowmeter |
| Core Function | Measures liquid flow externally through the pipe wall |
| Application | SITRANS FUP1010 field measurement systems |
Non-Intrusive Setup
Clamp-on transducers measure flow without cutting the pipe or contacting the liquid.
Portable Measurement
The weatherproof battery-powered unit supports field surveys and temporary measurement points.
Wide Pipe Coverage
Official technical data covers pipe outside diameters from 6.4 mm to 9.14 m.
Product Overview
The SITRANS FUP1010 is a portable transit-time ultrasonic flowmeter for measuring liquid flow through a closed pipe with externally mounted transducers.
This single-channel configuration combines a weatherproof IP67 enclosure, internal rechargeable battery, display, keypad, data logging and configurable analog outputs for field measurement tasks.
Key Functions
Clamp-On Transit-Time Measurement
Measures bidirectional liquid flow through the pipe wall, avoiding process penetration and pressure-boundary changes.
Portable Data Capture
Stores measurement sites and logged data for commissioning checks, troubleshooting and comparative surveys.
Flexible Signal Integration
Provides current, voltage, pulse-rate and serial outputs for recording or connection to external equipment.
Official Specifications
| Flow Velocity Range | ±12 m/s (±40 ft/s), bidirectional |
|---|---|
| Flow Sensitivity | 0.0003 m/s (0.001 ft/s), independent of flow rate |
| Pipe Size Range | 6.4 mm to 9.14 m (0.25 in to 360 in) |
| Analog Current Input | 20 mA DC |
| Temperature Input | 4-wire 1 kΩ RTD |
| Current Output | 20 mA DC; 1 kΩ load at 30 V DC |
| Voltage Output | 10 V DC; 5 kΩ minimum load |
| Pulse-Rate Output | Up to 5 kHz |
| Serial Interface | VT100-compatible RS 232 |
| Flow Accuracy Above 0.3 m/s | ±0.5% to ±2% of flow |
| Batch Repeatability Above 0.3 m/s | ±0.15% of flow |
| Enclosure Protection | IP67 weatherproof and impact-resistant |
| Ambient Operating Temperature | -18 to +60 °C |
| Battery Operating Time | 7 hours |
| Data Logger Memory | 1 MB |
| Stored Measurement Sites | Minimum 50 sites |
| Display | 128 × 240 pixel backlit LCD |
| Operator Keypad | 33 tactile-feedback buttons |
Frequently Asked Questions
Can 7ME35101CA000AA0 measure flow without cutting into the pipe?
Yes, the clamp-on transducers mount outside the pipe and do not contact the process liquid.
What pipe sizes can I survey with 7ME35101CA000AA0?
The supported pipe outside-diameter range is 6.4 mm to 9.14 m when the correct transducers and mounting hardware are selected.
Can 7ME35101CA000AA0 measure reverse flow?
Yes, the specified velocity range is bidirectional from -12 m/s to +12 m/s.
How long can 7ME35101CA000AA0 operate from its internal battery?
The specified battery operating time is seven hours under the stated operating conditions.
Which outputs can I use to record data from 7ME35101CA000AA0?
The unit provides current, voltage, pulse-rate and RS 232 signal options for external recording and integration.
What ambient temperature should I maintain around 7ME35101CA000AA0?
Operate the instrument within the specified -18 to +60 °C ambient range.
What should I confirm before installing transducers for 7ME35101CA000AA0?
Confirm the pipe dimensions, material, liquid properties, temperature and the transducer set required for the measurement point.