Overview

Siemens · SINAMICS AOP30

6SL3055-0AA00-4CA4 Advanced Operator Panel

Siemens 6SL3055-0AA00-4CA4 is a SINAMICS AOP30 advanced operator panel with a graphic backlit display, status LEDs and RS232 communication for local drive operation.

At a Glance

Brand Siemens
Model 6SL3055-0AA00-4CA4
Product Type Advanced operator panel
Core Function Provides local commissioning, parameterization, monitoring and fault display for SINAMICS drive systems
Application or Compatible Series SINAMICS cabinet drive and converter installations using the AOP30 operator interface

Drive Operation

Use the keypad and display for local setpoints, actual values, parameters, alarms and faults.

Cabinet Installation

Mount the panel in the cabinet door and maintain the documented front-side sealing.

Replacement Setup

Preserve language, communication and drive parameter settings before exchanging the panel.

Product Overview

Siemens 6SL3055-0AA00-4CA4 is a SINAMICS AOP30 advanced operator panel with a graphic backlit display, status LEDs and RS232 communication for local drive operation.

The backlit LCD presents plain text, bar graphs, operating values and diagnostic messages. Four LEDs identify run, alarm, fault and local or remote operating states. The RS232 interface uses the PPI protocol for communication with the connected SINAMICS system.

Ordering focus: confirm the complete article number, 24 V DC supply, cabinet cutout, RS232 connection, required language set and saved operator settings.

Key Functions

Graphic Local Interface

The backlit LCD presents plain text, bar graphs, operating values and diagnostic messages.

Status Indication

Four LEDs identify run, alarm, fault and local or remote operating states.

Drive Communication

The RS232 interface uses the PPI protocol for communication with the connected SINAMICS system.

Official Specifications

Rated Supply Voltage 24 V DC
Permitted Supply Range 20.4 to 28.8 V DC
Current without Backlight Less than 100 mA
Maximum Current with Backlight Less than 200 mA
Data Interface RS232
Communication Protocol PPI
Buffer Battery 3 V CR2032 lithium cell
Operating Temperature 0 to 55 °C
Storage and Transport Temperature -25 to +70 °C
Cabinet Interior Protection IP20
Front-Side Protection IP55
Dimensions 212 × 156 × 31 mm
Technical Weight Approximately 0.55 kg
Status Indicators RUN, ALARM, FAULT and Local/Remote LEDs

Frequently Asked Questions

How should 6SL3055-0AA00-4CA4 be powered during installation?

Use a regulated 24 V DC supply within the permitted voltage range and verify polarity before energizing the panel.

Which communication link does 6SL3055-0AA00-4CA4 use with the drive?

The operator panel communicates through its RS232 interface using the PPI protocol.

Can 6SL3055-0AA00-4CA4 be mounted in a cabinet door?

The panel is designed for cabinet-door installation with the documented front-side protection maintained.

What should be backed up before replacing 6SL3055-0AA00-4CA4?

Record the selected language, operator settings and relevant drive parameters before disconnecting the existing panel.

Which battery is used by 6SL3055-0AA00-4CA4?

The panel uses a 3 V CR2032 lithium cell for buffered functions.

What temperatures are suitable for 6SL3055-0AA00-4CA4 operation?

Operate the panel between 0 and 55 °C while keeping the cabinet ventilation within specification.

How can engineers use 6SL3055-0AA00-4CA4 for diagnostics?

Review the status LEDs and plain-text alarm or fault displays before checking the connected drive.

Compatibility & Ordering Notes

Before ordering 6SL3055-0AA00-4CA4: confirm the complete article number, 24 V DC supply, cabinet cutout, RS232 connection, required language set and saved operator settings.

Compatibility Checklist

  • Use the panel with the specified SINAMICS system and matching communication cable.
  • Verify the 24 V DC supply and cabinet-door mounting dimensions.
  • Preserve drive parameters and operator settings before replacement.
  • Check the RS232 cable routing and connector condition.
  • Confirm the required display language before commissioning.
Hot Selling Models
6SL3256-0AP00-0JA0
03089-3410
LRMA-M5-QS-4
RIC-AUX-20 38046024
IL24/230 DOR1/W-PAC
VMPA1-DP-PRS
6SN1161-1CA00-0BA1
NJ15-30GM50-A2-V1 17397S
0900530014
30-S-PNP 0301563
RIC-AUX-02 38046026
3SE6605-1BA02
6ES7193-6BP00-0BA1
3RP1513-2AQ30
DCN1-1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.