Siemens SINAMICS AOP30 6SL3055-0AA00-4CA4 Uzlabotais operatora panelis

Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses

Inscriptio electronica: [email protected]

whatsapp: +86-18150117685

  • Conspectus
  • Hot Selling Models
  • Producta commendata
Conspectus

Siemens · SINAMICS AOP30

6SL3055-0AA00-4CA4 Advanced Operator Panel

Siemens 6SL3055-0AA00-4CA4 is a SINAMICS AOP30 advanced operator panel with a graphic backlit display, status LEDs and RS232 communication for local drive operation.

Ad Primum Aspectum

Nota Siemens
Modellum 6SL3055-0AA00-4CA4
Typus Producti Advanced operator panel
Functio principalis Provides local commissioning, parameterization, monitoring and fault display for SINAMICS drive systems
Applicatio vel series compatibiles SINAMICS cabinet drive and converter installations using the AOP30 operator interface

Drive Operation

Use the keypad and display for local setpoints, actual values, parameters, alarms and faults.

Installatio armarum

Mount the panel in the cabinet door and maintain the documented front-side sealing.

Replacement Setup

Preserve language, communication and drive parameter settings before exchanging the panel.

Product Overview

Siemens 6SL3055-0AA00-4CA4 is a SINAMICS AOP30 advanced operator panel with a graphic backlit display, status LEDs and RS232 communication for local drive operation.

The backlit LCD presents plain text, bar graphs, operating values and diagnostic messages. Four LEDs identify run, alarm, fault and local or remote operating states. The RS232 interface uses the PPI protocol for communication with the connected SINAMICS system.

Focus ordinandi: confirm the complete article number, 24 V DC supply, cabinet cutout, RS232 connection, required language set and saved operator settings.

Key Functions

Graphic Local Interface

The backlit LCD presents plain text, bar graphs, operating values and diagnostic messages.

Indicatio status

Four LEDs identify run, alarm, fault and local or remote operating states.

Comunicazione con azionamenti

The RS232 interface uses the PPI protocol for communication with the connected SINAMICS system.

Official Specifications

Tensio nominalis supplicii 24 V DC
Permissum Supplicationis Intervallum 20,4 ad 28,8 V DC
Nunc currente absque retro-lumine Minus de 100 mA
Current maximum absque retro-lumine Minus quam 200 Ma
Interfacing Datorum RS232
Protocollo communicationis PPI
Accumulator Buffer cellula lithii CR2032 3 V
Temperatura operativa 0 ad 55 °C
Temperatura servandi et transportandi -25 ad +70 °C
Protezione Interna dell’Armadio IP20
Protectio Anterioris IP55
Dimensiones 212 × 156 × 31 mm
Pondus technicum Circa 0.55 kg
Indicatores Status LED RUN, ALARM, FAULT et LOCAL/REMOTE

Quaestiones Frequenter Rogatae

Quomodo 6SL3055-0AA00-4CA4 alendum est dum installatur?

Utere fonte regulato 24 V DC intra ambitum tensionis permissum et verificare polaritatem antequam tabulam activas.

Quae nexus communicationis 6SL3055-0AA00-4CA4 cum motore utitur?

Tabula operatoris communicat per suam interfaciem RS232 utendo protocollo PPI.

Can 6SL3055-0AA00-4CA4 be mounted in a cabinet door?

The panel is designed for cabinet-door installation with the documented front-side protection maintained.

What should be backed up before replacing 6SL3055-0AA00-4CA4?

Record the selected language, operator settings and relevant drive parameters before disconnecting the existing panel.

Which battery is used by 6SL3055-0AA00-4CA4?

The panel uses a 3 V CR2032 lithium cell for buffered functions.

What temperatures are suitable for 6SL3055-0AA00-4CA4 operation?

Operate the panel between 0 and 55 °C while keeping the cabinet ventilation within specification.

How can engineers use 6SL3055-0AA00-4CA4 for diagnostics?

Review the status LEDs and plain-text alarm or fault displays before checking the connected drive.

Compatibility & Ordering Notes

Ante ordinandum 6SL3055-0AA00-4CA4: confirm the complete article number, 24 V DC supply, cabinet cutout, RS232 connection, required language set and saved operator settings.

Index Compatibilitatis

  • Utere tabula cum specificato systemate SINAMICS et congruente cavo communicationis.
  • Verifica suppeditationem 24 V DC et dimensiones adfixionis in ostio armarii.
  • Serva parametres impulsum et positiones operatoris ante substitutionem.
  • Examina directionem cavi RS232 et statum connexorum.
  • Confirma linguam display necessariam ante commissionem.
Hot Selling Models
6SL3256-0AP00-0JA0
03089-3410
LRMA-M5-QS-4
RIC-AUX-20 38046024
IL24/230 DOR1/W-PAC
VMPA1-DP-PRS
6SN1161-1CA00-0BA1
NJ15-30GM50-A2-V1 17397S
0900530014
30-S-PNP 0301563
RIC-AUX-02 38046026
3SE6605-1BA02
6ES7193-6BP00-0BA1
3RP1513-2AQ30
DCN1-1

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Nomen
Nomen societatis
Nuntius
0/1000
epistula electronica ad Summum ire

Evolo Automation non est distributor autorizatus nisi aliter specificatum, nec representans, nec affinis fabricantis huius producti. Omnia signa propria et documenta sunt proprietatis suorum dominorum respective et data sunt ad identificationem et informationem.