Siemens SIMATIC S7-1200 6ES7215-1BG31-0XB0 CPU 1215C AC/DC/Relay Compact Controller
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Confirm that the exact BG31 AC/DC/relay article suffix matches the installed CPU.
- Keep plant power within 85 to 264 V AC and 47 to 63 Hz.
- Use STEP 7 V11 SP2 or later and retain the original Update 3 hardware support package where required.
- Match the CPU firmware and TIA Portal hardware-catalog entry to the saved project.
- Back up the PROFINET device name, IP address and both physical-port assignments.
- Match all connected digital, relay, voltage-input and current-output signal ranges.
- Keep local expansion within eight signal modules, three communication modules and one signal board.
Siemens · SIMATIC S7-1200
6ES7215-1BG31-0XB0 CPU 1215C AC/DC/Relay Compact Controller
Siemens 6ES7215-1BG31-0XB0 is the AC/DC/relay execution of the SIMATIC S7-1200 CPU 1215C. It combines an AC power input, integrated digital and analog I/O, two PROFINET ports, 100 KB of work memory and local expansion in one compact controller.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7215-1BG31-0XB0 |
| Product Type | CPU 1215C Compact Programmable Controller |
| Core Function | Executes machine logic, sequencing and industrial communications |
| Application or Compatible Series | SIMATIC S7-1200 automation system |
Power and I/O Form
Verify the AC-powered CPU, 24 V DC inputs and relay-output execution rather than the DC/DC/DC or DC/DC/relay variants.
Network Topology
Plan the two integrated PROFINET ports, IP settings and existing controller or device relationships before commissioning.
Local Expansion
Reserve capacity within the limits of eight signal modules, three communication modules and one signal board.
Product Overview
Siemens 6ES7215-1BG31-0XB0 is the AC/DC/relay execution of the SIMATIC S7-1200 CPU 1215C. It combines an AC power input, integrated digital and analog I/O, two PROFINET ports, 100 KB of work memory and local expansion in one compact controller.
Acquires digital and analog process signals and switches relay and current-output loads without a separate base I/O rack. Provides two integrated Ethernet and PROFINET ports for controller networking and device communications. Executes Boolean, word and floating-point logic with integrated load, work and retentive memory resources.
Key Functions
Integrated Mixed I/O
Acquires digital and analog process signals and switches relay and current-output loads without a separate base I/O rack.
Dual PROFINET Connectivity
Provides two integrated Ethernet and PROFINET ports for controller networking and device communications.
Program Execution and Retention
Executes Boolean, word and floating-point logic with integrated load, work and retentive memory resources.
Official Specifications
| Permissible AC Input Range | 85 to 264 V AC |
|---|---|
| Permissible Line Frequency | 47 to 63 Hz |
| Rated Input Current | 100 mA at 120 V AC; 50 mA at 240 V AC |
| Maximum Inrush Current | 20 A at 264 V AC |
| Backplane-Bus Supply Capacity | 1,600 mA maximum at 5 V DC for signal and communication modules |
| Typical Power Loss | 12 W |
| Integrated Work Memory | 100 KB |
| Integrated Load Memory | 4 MB |
| Maximum Retentive Data Area | 10 KB including timers, counters and flags |
| Bit-Memory Address Area | 8 KB |
| Adjustable Process Image | 1 KB inputs and 1 KB outputs |
| Typical Bit-Operation Time | 0.085 µs per instruction |
| Typical Word-Operation Time | 1.7 µs per instruction |
| Typical Floating-Point Operation Time | 2.5 µs per instruction |
| Integrated Digital Inputs | 14 at 24 V DC; six usable for high-speed counting |
| Integrated Digital Outputs | 10 relay outputs; 2 A maximum resistive load per output |
| Integrated Analog Inputs | 2 channels, 0 to 10 V DC |
| Integrated Analog Outputs | 2 channels, 0 to 20 mA DC |
| Local Expansion Capacity | Up to 3 communication modules, 1 signal board and 8 signal modules |
| Real-Time Clock Hold-Up | 480 h typical; maximum deviation ±60 s/month at 25 °C |
Frequently Asked Questions
Which STEP 7 version should I use for 6ES7215-1BG31-0XB0?
Use STEP 7 V11 SP2 or later, with the Update 3 hardware support package required for the original 2012 hardware integration.
Can 6ES7215-1BG31-0XB0 run from either 120 V or 230 V mains?
The AC input accepts 85 to 264 V AC at 47 to 63 Hz, covering both nominal supply classes.
How many local expansion modules can I add to 6ES7215-1BG31-0XB0?
The station can use up to eight signal modules, three communication modules and one signal board.
Which field signals can I connect directly to 6ES7215-1BG31-0XB0?
The CPU integrates 14 digital inputs, 10 relay outputs, two 0 to 10 V analog inputs and two 0 to 20 mA analog outputs.
Does 6ES7215-1BG31-0XB0 require a maintenance battery for memory backup?
The integrated backup is maintenance-free and batteryless, while the real-time clock has a typical hold-up time of 480 hours.
How should I connect 6ES7215-1BG31-0XB0 to a PROFINET network?
Use the two integrated PROFINET ports and preserve the project’s device name, IP configuration and network relationships during commissioning.
What must I compare before replacing 6ES7215-1BG31-0XB0?
Match the AC/DC/relay execution, firmware level, hardware-catalog entry, project backup and onboard I/O assignments before exchange.