siemens simatic net a5e00200965 02 cp 5614 a2 profibus pci processor-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC NET A5E00200965-02 CP 5614 A2 PROFIBUS PCI Communication Processor

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SIMATIC NET · PROFIBUS COMMUNICATION PROCESSOR

A5E00200965-02 CP 5614 A2 PROFIBUS PCI Communication Processor

Siemens A5E00200965-02 identifies a CP 5614 A2 communication processor that connects a PC to PROFIBUS and supports simultaneous DP master and DP slave communication.

At a Glance

Brand Siemens
Model A5E00200965-02
Product Type CP 5614 A2 communication processor
Core Function Connects a PC to PROFIBUS as DP master and DP slave
Application or Compatible Series SIMATIC NET PROFIBUS PC communication

Host Integration

Uses a PCI or PCI-X host interface for SIMATIC NET PC communication.

Dual PROFIBUS Role

Separate controllers support simultaneous DP master and DP slave operation.

Engineering Check

Match the host slot, PROFIBUS network and connector configuration before replacement.

Product Overview

The CP 5614 A2 is a SIMATIC NET communication processor for integrating an industrial PC into PROFIBUS networks. Its two network connectors and separate master and slave controllers support hierarchical network structures and program-controlled data transfer between the two communication paths.

The short PCI card supports plug-and-play operation, standard PROFIBUS transmission rates and a broad DP capacity. Replacement planning should preserve the host bus environment, PROFIBUS addressing, connector assignment and the existing SIMATIC NET configuration.

Ordering focus: Confirm the exact A5E identifier, CP 5614 A2 hardware, host PCI characteristics, SIMATIC NET software, both PROFIBUS networks and the saved configuration before ordering.

Key Functions

Simultaneous DP Operation

Operates as a DP master and DP slave through dedicated PROFIBUS controllers.

PC Network Connection

Provides a PCI or PCI-X interface for SIMATIC NET PROFIBUS communication.

Hierarchical Data Exchange

Transfers data under program control between master-side and slave-side networks.

Official Specifications

Card Format Short PCI PC card
Dimensions 107 × 18 × 168 mm
Net Weight 120 g
PCI Standard PCI V2.2 with plug-and-play support
Rated Supply 5 V DC; permissible range 4.75–5.25 V
Typical Slot Current 0.9 A
Host Bus Interface PCI or PCI-X, 3.3 V or 5 V, 32 bit, 33 or 66 MHz
PROFIBUS Connectors Two 9-pin D-sub female connectors with screw locking
Physical Transmission Electrically isolated RS-485 within SELV limits
Master Controller ASPC2R ST E2a
Slave Controller DPC31
PROFIBUS Data Rate 9.6 kbit/s to 12 Mbit/s
EMC Emission Class Class B to EN 55022 and FCC Class B
Signal-Line Surge Immunity ±2 kV to EN 61000-4-5
Contact-Discharge Immunity ±6 kV to IEC 61000-4-2
Storage and Transport Temperature −40 to +70 °C
Operating Relative Humidity 85% at 30 °C, non-condensing
DP Slave Process Data 244 bytes each for input, output and diagnostic data
DP Master Capacity Up to 124 DP slaves
DPC2 Connections Up to 56

Frequently Asked Questions

How should A5E00200965-02 be installed in an industrial PC?

Install the short PCI card in a compatible PCI or PCI-X slot, secure the bracket and connect the PROFIBUS cables only after the PC is isolated.

Which PROFIBUS data rates can A5E00200965-02 use?

The communication processor supports transmission rates from 9.6 kbit/s through 12 Mbit/s.

Can A5E00200965-02 operate as both a DP master and a DP slave?

The two-controller architecture allows simultaneous DP master and DP slave operation.

Which network connectors fit A5E00200965-02?

Use two 9-pin D-sub PROFIBUS connectors with screw locking for the network interfaces.

What should engineers back up before replacing A5E00200965-02?

Preserve the PC-station project, master and slave addresses, bus rates, connector assignments and SIMATIC NET access-point settings.

How much process data can A5E00200965-02 exchange through its slave interface?

The slave interface supports 244 bytes each of input data, output data and diagnostic data.

Which host-slot details matter when selecting A5E00200965-02?

Use a supported 32-bit PCI or PCI-X slot with the permitted 3.3 V or 5 V signaling and 33 or 66 MHz bus frequency.

Compatibility & Ordering Notes

Before ordering A5E00200965-02: Confirm the exact identifier, CP 5614 A2 hardware, host PCI characteristics, installed SIMATIC NET software, both PROFIBUS network assignments and the saved configuration.

Compatibility Checklist

  • Verify a compatible PCI or PCI-X host interface.
  • Confirm the configured PROFIBUS data rate and station addresses.
  • Back up communication settings before removing the installed card.
Hot Selling Models
Nordson 10 938041
VUVG-B10-B52-ZT-F-1P3
LRMA-1/8-QS-6
VHS40-F02A
RISH XMER 62/40
844141
HEE-D-MIDI-24-M12-SA
3RU1126-1FB0
6ES7193-6AR00-0AA0
LC1D18BD LADN22 LAD4TBDL
SAC-3P-M 8Y/2XM 8FS VP 1696222Y
02262883 010 1640 00085313 PT100 TW-03
376-0AA21
CD85N1070B
V3-WM-BK5M-PUR-U