Siemens FCI1801-B1 Cerberus ECO FC18R Line Card
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use the FC18R and FD181 system combination for this card.
- Check both the field-device count and the total line load factor.
- Set DIP positions 1–4 for the intended card address and leave positions 5–8 off.
- Use the specified nonpolar branch arrangement and keep cable length, resistance and capacitance within their limits.
FCI1801-B1 Cerberus ECO FC18R Line Card
Single-line FC18R expansion card for up to 252 FD181 field devices, with nonpolar two-wire branch connections and automatic short-circuit protection.
At a Glance
| Brand | Siemens |
|---|---|
| Model | FCI1801-B1 |
| Product Type | Addressable fire-panel line card |
| Core Function | Connection and supervision of field devices |
| Application | FC18R controllers with FD181 field devices |
Addressable field-device line
One line supports up to 252 field devices within a maximum line load factor of 1220.
Nonpolar branch wiring
The FD181 bus uses a nonpolar two-wire arrangement that allows branch connections.
Automatic line protection
Overload and short-circuit protection supervise the connected line and isolate a short-circuit condition.
Product Overview
FCI1801-B1 provides one field-device line for an FC18R fire controller and supports automatic recognition by the controller.
The card connects FD181-series devices through a nonpolar two-wire bus with branch wiring, and combines overload protection with automatic line protection during a short circuit.
Key Functions
Addressable field-device line
One line supports up to 252 field devices within a maximum line load factor of 1220.
Nonpolar branch wiring
The FD181 bus uses a nonpolar two-wire arrangement that allows branch connections.
Automatic line protection
Overload and short-circuit protection supervise the connected line and isolate a short-circuit condition.
Official Specifications
| Line capacity | 1 line with up to 252 field devices |
|---|---|
| Maximum line load factor | 1220 |
| Line topology and polarity | Nonpolar two-wire branch wiring |
| Recommended field cable | RVS1.0–RVS1.5 |
| Maximum branch distance | 1500 m |
| Maximum line resistance | 60 Ω for a single conductor |
| Maximum line capacitance | 500 nF |
| Line operating voltage | 24 V DC |
| Quiescent current | 30 mA |
| Maximum current | 1.5 A |
| Protection functions | Overload protection and automatic short-circuit isolation |
| Operating temperature | 0 to +50°C |
| Storage temperature | −20 to +60°C |
| Relative humidity | 95% maximum at 40 ±2°C |
| Board dimensions | 155 × 120 mm |
| Weight | 0.095 kg |
| Card address range | 6–13, set with DIP positions 1–4 |
Frequently Asked Questions
Which controller and detector family can use FCI1801-B1?
The card is designed for FC18R controllers and FD181-series field devices.
How many field devices may I connect to FCI1801-B1?
One card supports up to 252 field devices while remaining within the maximum line load factor of 1220.
Must I observe bus polarity when wiring FCI1801-B1?
The FD181 field bus uses a nonpolar two-wire connection with branch wiring.
How long may a branch connected to FCI1801-B1 be?
The maximum branch wiring distance is 1500 m.
How do I assign the panel address of FCI1801-B1?
Set an address from 6 to 13 using DIP positions 1–4 and leave positions 5–8 switched off.
What protection does FCI1801-B1 provide against a shorted line?
The card automatically activates line protection when a short circuit occurs.
What electrical limits should I check on the wiring to FCI1801-B1?
Keep single-conductor resistance within 60 Ω and line capacitance within 500 nF.