Siemens SIWAREX U Single-Channel Weighing Module 7MH4950-1AA01

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS · SIWAREX U for SIMATIC S7-300 and ET 200M

7MH4950-1AA01 SIWAREX U Single-Channel Weighing Module

The SIWAREX U is a single-channel weighing module for SIMATIC S7-300 and ET 200M systems, designed for platform or hopper scales using analog full-bridge load cells.

At a Glance

Brand Siemens
Model 7MH4950-1AA01
Product Type single-channel electronic weighing module
Core Function Evaluates full-bridge load-cell signals for industrial weighing
Application or Compatible Series SIMATIC S7-300 or ET 200M hopper and platform scale applications

Exact Identification

Match 7MH4950-1AA01 character by character and confirm the complete SIWAREX U Single-Channel Weighing Module designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The SIWAREX U is a single-channel weighing module for SIMATIC S7-300 and ET 200M systems, designed for platform or hopper scales using analog full-bridge load cells.

One weighing channel evaluates compatible analog load cells with a 1 to 4 mV/V signal range. The module operates in supported S7-300 or ET 200M stations and exchanges process data through the backplane bus. An integrated RS 232 connection supports commissioning and service access with the appropriate engineering tools.

Ordering focus: confirm the complete article number, single-channel requirement, load-cell bridge and sensitivity, front connector, calibration data and station configuration.
Key Functions

Single-Scale Measurement

One weighing channel evaluates compatible analog load cells with a 1 to 4 mV/V signal range.

SIMATIC Integration

The module operates in supported S7-300 or ET 200M stations and exchanges process data through the backplane bus.

Service Interface

An integrated RS 232 connection supports commissioning and service access with the appropriate engineering tools.

Official Specifications
Weighing Channels 1
Supported Scale Types Platform and hopper scales
Load-Cell Circuit Analog full bridge
Load-Cell Signal Range 1 to 4 mV/V
Load-Cell Interfaces 1
Service Interface 1 x RS 232
Rated External Supply 24 V DC
Internal Supply 5 V DC
Rated Current 0.15 A
Permitted Ambient Temperature 0 to 60 °C
Front Connector 20-pin
Backplane Connection S7 bus connector
Approximate Module Weight 0.3 kg
Frequently Asked Questions

Which scale types suit 7MH4950-1AA01?

It is intended for supported platform and hopper scales using analog full-bridge load cells.

How many weighing channels does 7MH4950-1AA01 provide?

The module provides one weighing channel.

What load-cell sensitivity can be connected to 7MH4950-1AA01?

Use compatible load cells with a nominal signal range of 1 to 4 mV/V.

Can 7MH4950-1AA01 be installed in an ET 200M station?

Yes; it supports approved ET 200M configurations as well as S7-300 stations.

Which service interface is available on 7MH4950-1AA01?

An RS 232 connection is available for commissioning and service access.

What should be saved before replacing 7MH4950-1AA01?

Record the calibration values, scale parameters, zero point, limits, filter settings and PLC configuration.

What wiring should be checked when installing 7MH4950-1AA01?

Verify load-cell polarity, shielding, excitation, signal leads, 24 V supply and the 20-pin front connector.

Compatibility & Ordering Notes
Before ordering 7MH4950-1AA01: confirm the complete article number, single-channel requirement, load-cell bridge and sensitivity, front connector, calibration data and station configuration.

Compatibility Checklist

  • Confirm an approved S7-300 or ET 200M slot and bus configuration.
  • Match the load-cell bridge type, sensitivity, cable shielding and connector assignment.
  • Preserve calibration and scale parameters before exchanging the module.
Hot Selling Models
3RA1931-1AA00
7000-40041-6350500
3RV1915-5A
XVUC21B
3TX7004-1LB00
5SX21C6 5SX9100
PLC-BSC-24DC/1/SEN
3RV2917-1A
55.34.9.024.0040
RE3-1-202/1
ASC-29320 ASC-29320/FSC
5SX21 5SX91
Type 3600
SAC-4P-M12MSD/2.0-933/M12MSD
Siemens 3SB1000-4LB01

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.