Overview
SIMODRIVE 611 universal

6SN1114-0NB00-0AA2 SIMODRIVE 611 Universal PROFIBUS-DP2 Option Module

PROFIBUS-DP2 option for cyclic drive data, acyclic parameter access and commissioning through SimoCom U.

At a Glance

Brand Siemens
Model 6SN1114-0NB00-0AA2
Product Type PROFIBUS-DP2 option board
Core Function Drive communication with a PROFIBUS DP master
Application SIMODRIVE 611 universal control boards

Cyclic command exchange

PKW and PZD communication carries drive parameters, commands and operating feedback between the drive and DP master.

Acyclic engineering access

DP/V1 services and SimoCom U over PROFIBUS provide parameter and commissioning access alongside process communication.

Automatic bus-rate detection

The slave detects the configured PROFIBUS transmission rate at power-on, while its front diagnostic LED indicates communication state.

Product Overview

6SN1114-0NB00-0AA2 connects a SIMODRIVE 611 universal control board to a PROFIBUS DP master as a slave station, carrying cyclic process data and parameter traffic through the drive communication interface.

The DP2 option uses a DPC31 ASIC without a PLL and supports control-board software from version 3.1; its communication capabilities include acyclic DP/V1 access and SimoCom U operation over PROFIBUS.

Ordering focus: Match the DP2 option to a SIMODRIVE 611 universal control board with software version 3.1 or later and retain the installed PROFIBUS configuration.
Key Functions

Cyclic command exchange

PKW and PZD communication carries drive parameters, commands and operating feedback between the drive and DP master.

Acyclic engineering access

DP/V1 services and SimoCom U over PROFIBUS provide parameter and commissioning access alongside process communication.

Automatic bus-rate detection

The slave detects the configured PROFIBUS transmission rate at power-on, while its front diagnostic LED indicates communication state.

Official Specifications
Communication ASIC DPC31 without PLL
Cyclic data channels PKW parameter channel and PZD process data
Acyclic communication DP/V1 services
Electrical bus rates 9.6, 19.2, 93.75, 187.5 and 500 kbaud; 1.5, 3, 6 and 12 Mbaud
Transmission-rate selection Automatic detection at power-on
Optical link plug limit 1.5 Mbaud maximum with OLP optical link plugs
Drive bus connection X423 PROFIBUS connector
Local diagnostic indication Bicolor LED for option activation and cyclic communication status
Frequently Asked Questions

Can 6SN1114-0NB00-0AA2 replace an older DP1 option?

The DP2 board can replace a DP1 option when the SIMODRIVE control board runs software version 3.1 or later.

Which drive data can I exchange cyclically through 6SN1114-0NB00-0AA2?

The connection provides PKW parameter traffic and PZD process data for drive commands and feedback.

Can I commission the drive through 6SN1114-0NB00-0AA2 using SimoCom U?

SimoCom U can communicate with the drive over PROFIBUS through the DP2 option.

How is the bus transmission rate selected on 6SN1114-0NB00-0AA2?

The option automatically detects the PROFIBUS transmission rate when power is applied.

Will an optical link plug retain the 12 Mbaud capability of 6SN1114-0NB00-0AA2?

An OLP optical link plug limits the connection to a maximum of 1.5 Mbaud.

Where do I assign the PROFIBUS station address for 6SN1114-0NB00-0AA2?

Set the slave address with drive parameter P0918 and align it with the master configuration.

What should I inspect if 6SN1114-0NB00-0AA2 has no cyclic communication?

Inspect the slave address, bus connection, termination and connected bus cables when the option is enabled but cyclic data exchange is absent.

Compatibility & Ordering Notes
Before ordering 6SN1114-0NB00-0AA2: Match the DP2 option to a SIMODRIVE 611 universal control board with software version 3.1 or later and retain the installed PROFIBUS configuration.

Before installation

  • Use control-board software version 3.1 or later for the DP2 option.
  • Set P0918 for the slave address, P0700 for the required drive operating mode and P0875 for slave activation.
  • Tighten the option retaining and shield-contact screws to no more than 0.8 Nm.
  • Keep the master and all bus participants at the same transmission rate, applying the 1.5 Mbaud limit when OLP optical link plugs are fitted.
Hot Selling Models
PM24801-NPK09
E3S-2LB4
46/44.6-S12 50040433
553482305054
WAGO 2016-7601
DILA-XHI31
1690040000
ABB 1SVR405651R1000
SDE5-D10-O-Q6-P-M8
SAC-5P-M12MS
6502903003 KIB-M12PS/002-KL2
SDR11 PE100
CES-EA-TC-AK08-104776
DILAXHI31
BFB0003 BFB 75K-001-P-02

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.