Siemens 6SL5568-0XX00-0AA0 SINAMICS S200 Connector Kit
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Confirm the converter is S200 rather than S200 Basic.
- Match X124, X1, X2 and X108 to the existing connection duties.
- Check the X131 connector against the validated safety circuit.
- Select the safety-device connector or disable plug according to the approved machine design.
- Retain the included shield plate and four fixing screws in the installation.
6SL5568-0XX00-0AA0 SINAMICS S200 Connector Kit
A replacement connector kit for SINAMICS S200 power, holding-brake and STO connections, including a shield plate and four fixing screws.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL5568-0XX00-0AA0 |
| Product Type | Converter connector kit |
| Core Function | Replacing front-panel electrical connectors |
| Application | SINAMICS S200 PN and S200 PTI converters |
Front-panel service
Replacement plugs support the converter’s electrical connection points.
Power and brake plugs
Separate connectors serve the incoming supply, motor and holding brake.
STO connector selection
The safety-device connector and disable plug have different purposes.
Product Overview
6SL5568-0XX00-0AA0 provides replacement front-panel connectors for the SINAMICS S200 converter. The kit contains plugs for the power supply, motor, holding brake and STO connections.
The kit serves compatible S200 PN and S200 PTI converters, while S200 Basic uses a different kit. A shield plate with four fixing screws is included alongside the specified electrical connectors.
Key Functions
Restore power connections
The X124, X1 and X2 plugs serve the external 24 V supply, main supply and motor connection.
Connect the holding brake
The X108 plug provides the separate motor holding-brake connection on S200 PN.
Service the STO interface
The X131 connector supports the safety-device interface; select the appropriate plug for the approved machine configuration.
Official Specifications
| X124 connector duty | External 24 V DC supply |
|---|---|
| X1 connector duty and included parts | Main supply; internal braking-resistor jumper and R1 terminal blanking plug included |
| X2 connector duty | Motor power connection |
| X108 connector duty | Motor holding-brake connection on S200 PN |
| X131 safety-device connector | Six positions: STO1+, STO1−, STO-VS, STO-M, STO2+, STO2− |
| Additional X131 plug | STO disable plug included |
| Included shielding hardware | One shield plate with four fixing screws |
Frequently Asked Questions
Does 6SL5568-0XX00-0AA0 also identify the S200 Basic connector kit?
The S200 Basic kit has the separate order number 6SL5668-0XX00-0AA0.
Which plug in 6SL5568-0XX00-0AA0 serves the external 24 V supply?
The external 24 V DC supply connects through X124.
Are the motor power and holding-brake plugs separate in 6SL5568-0XX00-0AA0?
Motor power uses X2 and the S200 PN holding brake uses X108.
Which braking-resistor connection parts accompany X1 in 6SL5568-0XX00-0AA0?
The X1 supply plug includes the internal braking-resistor jumper and the R1 terminal blanking plug.
How are the six X131 positions associated with 6SL5568-0XX00-0AA0 assigned?
They provide two STO channel pairs together with the STO supply and reference-ground terminals.
Are the X131 safety-device plug and disable plug in 6SL5568-0XX00-0AA0 interchangeable in function?
The safety-device plug connects external safety devices, whereas the disable plug disables the Safety Integrated functions.
Does 6SL5568-0XX00-0AA0 include the shield plate and its mounting screws?
The kit includes one shield plate with four fixing screws.