Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6sl3244 0sa01 1aa1 et 200s fc icu24f fail safe control unit-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SL3244-0SA01-1AA1 ET 200S FC ICU24F Fail-Safe Control Unit

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMATIC ET 200S FC

6SL3244-0SA01-1AA1 ET 200S FC ICU24F Fail-Safe Control Unit

ICU24F drive control with motor feedback, RS232 commissioning, parameter backup and STO, SS1 and SLS functions in the ET 200S FC system.

At a Glance

Brand Siemens
Model 6SL3244-0SA01-1AA1
Product Type Fail-safe inverter control unit
Core Function Motor regulation with integrated safety functions
Application Distributed ET 200S drive stations with IPM25 power modules

Integrated safe motion functions

The ICU24F supports Safe Torque Off, Safe Stop 1 and Safely Limited Speed through the configured ET 200S safety groups.

Motor feedback and protection

PTC/KTY84 temperature monitoring and single-ended HTL incremental feedback support motor control and diagnostic functions.

Commissioning and parameter handling

RS232 provides STARTER access, while the MMC slot supports parameter transfer and replacement workflows.

Product Overview

6SL3244-0SA01-1AA1 is an ICU24F fail-safe control unit for the ET 200S FC distributed frequency converter. It regulates the associated IPM25 power module and exchanges control and diagnostic information with the higher-level controller through the IM151 interface module.

The control unit combines motor-temperature and speed-feedback interfaces with RS232 access for STARTER and an MMC slot for parameter storage. Its fail-safe functions are integrated into the station shutdown groups G1 through G6.

Ordering focus: Check the ICU24F hardware and software revision, TM-ICU15 terminal module, fail-safe potential group and compatible IPM25 power module before replacement.
Key Functions

Integrated safe motion functions

The ICU24F supports Safe Torque Off, Safe Stop 1 and Safely Limited Speed through the configured ET 200S safety groups.

Motor feedback and protection

PTC/KTY84 temperature monitoring and single-ended HTL incremental feedback support motor control and diagnostic functions.

Commissioning and parameter handling

RS232 provides STARTER access, while the MMC slot supports parameter transfer and replacement workflows.

Official Specifications
Current consumption 0.4 A typical; 0.8 A maximum
Dimensions (W × H × D) 15 × 220 × 156 mm, including terminal-module mounting depth
Weight Approximately 250 g
Operating temperature −10 to +60 °C horizontal; −10 to +40 °C vertical installation
Degree of protection IP20
Maximum achievable safety classification SIL 2 to IEC 61508; Category 3 to EN 954-1
PFH value 1.46 × 10⁻7 per hour
Safety-related service life 10 years
Frequency resolution 0.01 Hz for digital/serial setpoint and output-frequency resolution
Commissioning interface RS232 for STARTER
Motor-temperature interface PTC / KTY84
Encoder interface 9-pin D-sub socket for single-ended HTL incremental encoders
Encoder supply Unregulated 24 V supplied through the control-unit connector
Safety functions STO, SS1 and SLS
Diagnostic indicators 10 LEDs: SF, RDY, STO, ES and SG1–SG6
Frequently Asked Questions

Which terminal module is required for 6SL3244-0SA01-1AA1?

Use TM-ICU15 in a suitable fail-safe potential group with the IPM25 power module positioned to its right.

Which encoder signals can 6SL3244-0SA01-1AA1 evaluate?

The encoder interface accepts single-ended HTL incremental signals, with A and B tracks needed to evaluate both speed and direction.

Should an external supply power the encoder connected to 6SL3244-0SA01-1AA1?

The control unit supplies the encoder with unregulated 24 V through its D-sub connector, so an external encoder supply must not be connected.

How is a KTY84 connected to 6SL3244-0SA01-1AA1?

Connect the KTY anode to pin 1 and its cathode to pin 2 of the temperature-sensor interface.

Which parameter memory is listed for 6SL3244-0SA01-1AA1?

Use MMC parameter memory 6SL3254-0AM00-0AA0 for parameter handling.

How much control-supply current should be allowed for 6SL3244-0SA01-1AA1?

Allow up to 0.8 A per control unit and include every other load when checking the potential-group power-module limit.

Can a standard ICU24 replace 6SL3244-0SA01-1AA1?

A fail-safe ICU24F must not be replaced with a non-fail-safe ICU24.

Compatibility & Ordering Notes
Before ordering 6SL3244-0SA01-1AA1: Check the ICU24F hardware and software revision, TM-ICU15 terminal module, fail-safe potential group and compatible IPM25 power module before replacement.

Before installation

  • Verify the hardware/software revision against the installed drive configuration; the Siemens certificate lists hardware A01/A02 with safety software 03.00.49.00 for this order number.
  • Use the specified TM-ICU15 and compatible IPM25 combination, and check the complete potential-group current budget.
  • Plan encoder, temperature-sensor and RS232 connections using the Siemens connector assignments.
  • Complete drive commissioning and the required safety validation for the assembled machine before operation.
Hot Selling Models
DO16-T - 2753643
ISW-30sg80b10-3NT1A
7000-16011-3320500
0830100387
NEBC-D8G4-ES-2-NS-D8G4-ET
8/3-2A
R12-22-502
6ES7120-0BH01-0AA0
6ES5431-6AA11
DSNU-25-160-PPS-A
6EP1931-2DC21
VSVA-B-M52-MZH-A1-1R5L
VSVA-B-M52-MZ-A1-1C1-APC
NJ5-18GM-N 14545S
010516

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.