- Verifica revisionem hardware/software ad configurationem impulsum installatum; certificatum Siemens indicat hardware A01/A02 cum software tutelae 03.00.49.00 pro hoc numero ordinis.
- Utere TM-ICU15 specificata et combinatione IPM25 compatibili, et inspice totum praebitum currentis pro gruppo potentiali.
- Planifica conexiones encoder, sensoris temperaturae et RS232 utendo attributionibus connectorum Siemens.
- Absolvi commissioning impulsum et validationem tutelae requisitam pro machina composita antequam operatio incipiat.
6SL3244-0SA01-1AA1 ET 200S FC ICU24F Fail-Safe Control Unit
ICU24F drive control with motor feedback, RS232 commissioning, parameter backup and STO, SS1 and SLS functions in the ET 200S FC system.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6SL3244-0SA01-1AA1 |
| Typus Producti | Fail-safe inverter control unit |
| Functio principalis | Motor regulation with integrated safety functions |
| Applicatio | Distributed ET 200S drive stations with IPM25 power modules |
Integrated safe motion functions
The ICU24F supports Safe Torque Off, Safe Stop 1 and Safely Limited Speed through the configured ET 200S safety groups.
Motor feedback and protection
PTC/KTY84 temperature monitoring and single-ended HTL incremental feedback support motor control and diagnostic functions.
Commissioning and parameter handling
RS232 provides STARTER access, while the MMC slot supports parameter transfer and replacement workflows.
Product Overview
6SL3244-0SA01-1AA1 is an ICU24F fail-safe control unit for the ET 200S FC distributed frequency converter. It regulates the associated IPM25 power module and exchanges control and diagnostic information with the higher-level controller through the IM151 interface module.
The control unit combines motor-temperature and speed-feedback interfaces with RS232 access for STARTER and an MMC slot for parameter storage. Its fail-safe functions are integrated into the station shutdown groups G1 through G6.
Key Functions
Integrated safe motion functions
The ICU24F supports Safe Torque Off, Safe Stop 1 and Safely Limited Speed through the configured ET 200S safety groups.
Motor feedback and protection
PTC/KTY84 temperature monitoring and single-ended HTL incremental feedback support motor control and diagnostic functions.
Commissioning and parameter handling
RS232 provides STARTER access, while the MMC slot supports parameter transfer and replacement workflows.
Official Specifications
| Consumptio currentis | 0.4 A typical; 0.8 A maximum |
|---|---|
| Dimensiones (L × H × D) | 15 × 220 × 156 mm, includens profunditatem montagis moduli terminalis |
| Pondus | Circa 250 g |
| Temperatura operativa | −10 usque ad +60 °C horizontaliter; −10 usque ad +40 °C verticaliter installatus |
| Gradus praesidium | IP20 |
| Maxima classificatio securitatis attingibilis | SIL 2 ad IEC 61508; Categoria 3 ad EN 954-1 |
| PFH Value | 1.46 × 10⁻⁷ per horam |
| Vita operativa ad securitatem pertinentis | x annos |
| Resolutio frequentiae | 0.01 Hz pro digitali/seriali puncto consignato et resoluto frequentiae output |
| Interface de mise en service | RS232 pro STARTER |
| Interfacs temperaturae motoris | PTC / KTY84 |
| Interfacs Encoder | 9-pin D-sub socket for single-ended HTL incremental encoders |
| Alimentatio encoderis | Unregulated 24 V supplied through the control-unit connector |
| Funções de Segurança | STO, SS1 and SLS |
| Indicatores Diagnostici | 10 LEDs: SF, RDY, STO, ES and SG1–SG6 |
Quaestiones Frequenter Rogatae
Which terminal module is required for 6SL3244-0SA01-1AA1?
Use TM-ICU15 in a suitable fail-safe potential group with the IPM25 power module positioned to its right.
Which encoder signals can 6SL3244-0SA01-1AA1 evaluate?
Interfacs encoder accipit signa incrementalia HTL unipolaria; tracciae A et B necessariae sunt ad aestimandam tam celeritatem quam directionem.
Num suppletio externa debet impellere encoderem coniunctum ad 6SL3244-0SA01-1AA1?
Unitas de controllo supplet encoderem voltibus 24 V non regulatis per suum connexum D-sub; ergo suppletio externa encoderis non debet coniungi.
Quomodo KTY84 coniungitur ad 6SL3244-0SA01-1AA1?
Coniunge anodum KTY ad pinum 1 et catodum ad pinum 2 interfaccis sensoris temperaturae.
Quae memoria parametrorum enumeratur pro 6SL3244-0SA01-1AA1?
Utere memoria parametrorum MMC 6SL3254-0AM00-0AA0 pro tractatione parametrorum.
Quantus currus suppletionis de controllo permittendus est pro 6SL3244-0SA01-1AA1?
Permitte usque ad 0,8 A per unitatem de controllo et omnes alias onerations includere dum limites moduli potentiae gruppi potentialis examinantur.
Num ICU24 communis potest 6SL3244-0SA01-1AA1 substituere?
Un ICU24F cum functione tutelae non potest substitui per ICU24 sine functione tutelae.