siemens 6sl3210 5be25 5uv0 sinamics v20 5 5 kw three phase inverter-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SL3210-5BE25-5UV0 SINAMICS V20 5.5 kW Three-Phase Inverter

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SINAMICS V20 • Compact Drive Control

6SL3210-5BE25-5UV0 SINAMICS V20 5.5 kW Three-Phase Inverter

Unfiltered 5.5 kW SINAMICS V20 for 380–480 V three-phase input, with USS/Modbus RTU communication and 0–550 Hz output.

At a Glance

Brand Siemens
Model 6SL3210-5BE25-5UV0
Product Type Frequency inverter
Core Function Variable-speed control of AC motors
Application Three-phase industrial motor-drive installations

Variable-frequency motor control

Provides three-phase output over 0–550 Hz for a 5.5 kW drive application.

Local and serial control

Four digital inputs, two analog inputs, relay/transistor outputs and USS/Modbus RTU support the control arrangement.

Overload handling

Low-overload operation permits 110% current and high-overload operation permits 150% current for 60 seconds in a 300-second cycle.

Product Overview

6SL3210-5BE25-5UV0 provides 5.5 kW motor-drive control from a three-phase 380–480 V supply, with an IEC rated output current of 12.5 A.

The unfiltered FSC unit includes digital and analog I/O for local control and serial USS/Modbus RTU communication; motor-cable length and temperature derating should be included in the installation plan.

Ordering focus: Match the three-phase supply and regional output-current rating, plan EMC measures for the unfiltered unit and apply derating from 40 °C.
Key Functions

Variable-frequency motor control

Provides three-phase output over 0–550 Hz for a 5.5 kW drive application.

Local and serial control

Four digital inputs, two analog inputs, relay/transistor outputs and USS/Modbus RTU support the control arrangement.

Overload handling

Low-overload operation permits 110% current and high-overload operation permits 150% current for 60 seconds in a 300-second cycle.

Official Specifications
Input supply 3-phase 380–480 V AC, −15%/+10%
Input frequency 47–63 Hz
Rated motor power 5.5 kW / 7.5 hp
Rated output current 12.5 A IEC; 11 A NEC for the specified 440–480 V rating
Output frequency 0–550 Hz
Pulse frequency 4 kHz
Overload duty LO: 110%; HO: 150%, each for 60 s in a 300 s cycle
Serial communication USS and Modbus RTU
Digital inputs 4 standard inputs
Analog inputs 2, usable as additional digital inputs
Digital outputs 1 relay changeover contact and 1 transistor output
Analog outputs 1
Integrated EMC filter Unfiltered
Integrated braking chopper Not fitted
Maximum motor cable 25 m shielded; 50 m unshielded
Operating temperature −10 to +60 °C; derating required from 40 °C
Cooling method External fan
Protection and frame IP20 / UL open type; FSC
Dimensions (W × H × D) 184 × 182 × 169 mm
Net weight 2.4 kg
Frequently Asked Questions

Can 6SL3210-5BE25-5UV0 be supplied from a single-phase 230 V circuit?

The specified input is three-phase 380–480 V AC.

Why are two rated output currents shown for 6SL3210-5BE25-5UV0?

The rating is 12.5 A under IEC conditions and 11 A for the specified NEC 440–480 V condition.

Does 6SL3210-5BE25-5UV0 include an EMC filter?

This article is the unfiltered version, so the installation must provide the required EMC measures.

What serial control protocols can be used with 6SL3210-5BE25-5UV0?

The inverter supports USS and Modbus RTU.

Can a 50 m shielded motor cable be used with 6SL3210-5BE25-5UV0?

The specified shielded motor-cable limit is 25 m, while the unshielded limit is 50 m.

At what temperature does output derating begin for 6SL3210-5BE25-5UV0?

Apply derating at ambient temperatures of 40 °C or higher.

Is a braking chopper built into 6SL3210-5BE25-5UV0?

An integrated braking chopper is not fitted.

Compatibility & Ordering Notes
Before ordering 6SL3210-5BE25-5UV0: Match the three-phase supply and regional output-current rating, plan EMC measures for the unfiltered unit and apply derating from 40 °C.

Before installation

  • Match the input supply, motor data and regional current rating before commissioning.
  • Plan the required EMC arrangement for the unfiltered inverter.
  • Keep the motor cable within the shielded or unshielded limit that applies to the installation.
  • Allow for fan cooling, IP20 cabinet protection and current derating from 40 °C.
Hot Selling Models
1794-IB16
MEX3D21B22
702244/804
1701250000 SAI-8-M
ADN-32-3-IPA
A55B
PKZM0-0.63-T
GPP P30158
NF5023
L-PPS604-20-32/4 32.1100.208-00
TB2-STS4P250 T2PM25A4A-TEE
CPE18-M1H-3GLS-QS-10 163161 F702
P1-25/EA/SVB/N 06M2020
HEL-D-MIDI 186521
NZ1VZ-538 C1233

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.