Siemens 6SL3210-5BB17-5AV0 0.75 kW Single-Phase Input Inverter
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Verify the Single-phase 200–240 V AC, −10%/+10% input supply.
- Size the motor circuit against the 0.75 kW and 3.90 A output rating.
- Account for the integrated class a filter configuration in the EMC design.
- Apply output derating from 40 °C and retain the required convection-cooling space.
- Keep motor cables within the shielded or unshielded length limit.
- Plan external braking equipment if the application requires it.
6SL3210-5BB17-5AV0 0.75 kW Single-Phase Input Inverter
A 0.75 kW SINAMICS V20 inverter with single-phase 200–240 V input, 3.90 A rated output and integrated Class A filtering.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3210-5BB17-5AV0 |
| Product Type | Compact frequency inverter |
| Core Function | Controls the frequency and speed of a three-phase motor |
| Application | Compact machine drives supplied from single-phase 200–240 V AC |
0.75 kW motor drive
A three-phase output stage supplies a rated current of 3.90 A.
Single-phase mains
The input accepts 200–240 V AC at 47–63 Hz.
Compact convection cooling
The FSA enclosure is naturally cooled and measures 90 × 150 × 145.5 mm.
Product Overview
6SL3210-5BB17-5AV0 converts a single-phase 200–240 V AC supply into a controlled three-phase motor output for compact machine drives.
The 0.75 kW FSA variant combines an integrated Class A filter, convection cooling, four digital inputs and USS or Modbus RTU communication.
Key Functions
Motor frequency control
The three-phase output is adjustable over 0–550 Hz, with a rated motor power of 0.75 kW and a rated output current of 3.90 A.
Integrated EMC filtering
The drive includes a Class A filter and specifies maximum motor-cable lengths of 10 m shielded or 50 m unshielded.
Local and serial integration
Four standard digital inputs, two analog inputs, one analog output and relay plus transistor outputs support machine connections, with USS and Modbus RTU for serial control.
Official Specifications
| Input supply | Single-phase 200–240 V AC, −10%/+10% |
|---|---|
| Input line frequency | 47–63 Hz |
| Rated output voltage | Three-phase; 230 V IEC / 240 V NEC |
| Rated power, LO and HO | 0.75 kW |
| Rated output current, LO and HO | 3.90 A |
| Pulse frequency | 8 kHz |
| Output frequency | 0–550 Hz |
| Low-overload capability | 110% rated output current for 60 s; 300 s cycle |
| High-overload capability | 150% rated output current for 60 s; 300 s cycle |
| Integrated filter | Integrated Class A filter |
| Braking chopper | Not integrated |
| Digital control inputs | 4 standard digital inputs |
| Digital control outputs | 1 relay changeover output and 1 transistor output |
| Analog I/O | 2 analog inputs, also usable as digital inputs; 1 analog output |
| Cooling method | Convection cooling |
| Operating ambient temperature | −10 to +60 °C; derating from 40 °C |
| Maximum motor cable length | 10 m shielded; 50 m unshielded |
| Protection and frame size | IP20 / UL open type; FSA |
| Dimensions (W × H × D) | 90 × 150 × 145.5 mm |
| Net weight | 1.10 kg |
Frequently Asked Questions
Can 6SL3210-5BB17-5AV0 operate from a single-phase workshop supply?
The input is rated for single-phase 200–240 V AC with a −10% to +10% voltage tolerance at 47–63 Hz.
Which motor current should be used to size 6SL3210-5BB17-5AV0?
The rated output current is 3.90 A for both low-overload and high-overload ratings.
What EMC filter is already installed in 6SL3210-5BB17-5AV0?
The inverter includes an integrated Class A filter.
What shielded motor-cable length is specified for 6SL3210-5BB17-5AV0?
The maximum shielded motor-cable length is 10 m.
How is heat removed from 6SL3210-5BB17-5AV0?
The inverter uses convection cooling rather than a cooling fan.
Does 6SL3210-5BB17-5AV0 retain its full output throughout the entire ambient-temperature range?
Operation is specified from −10 to +60 °C, with derating required from 40 °C.
What pulse frequency is listed for 6SL3210-5BB17-5AV0?