Siemens 6SL3210-1PE21-8UL0 SINAMICS G120 PM240-2 Unfiltered Power Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use 7.5 kW / 18.0 A for LO or 5.5 kW / 13.2 A for HO sizing.
- Provide a three-phase 380–480 V line supply.
- Allow 9.2 l/s cooling airflow and 0.2 kW heat dissipation.
- Coordinate external EMC measures and the specified branch fuses.
SINAMICS G120 • FRAME SIZE B
6SL3210-1PE21-8UL0 SINAMICS G120 PM240-2 Unfiltered Power Module
Unfiltered PM240-2 power stage rated 7.5 kW for low overload or 5.5 kW for high overload on a 380–480 V three-phase supply.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3210-1PE21-8UL0 |
| Product Type | Converter power module |
| Core Function | Motor inverter power stage |
| Compatible Series | SINAMICS G120 |
Two duty ratings
The power stage provides 18.0 A in low-overload service and 13.2 A in high-overload service.
Unfiltered input
This variant has no integrated line filter, so EMC measures belong in the cabinet design.
Forced-air cooling
A 9.2 l/s cooling-air requirement and 0.2 kW power loss define the cabinet cooling load.
Product Overview
6SL3210-1PE21-8UL0 is an unfiltered PM240-2 power module in frame size B for modular SINAMICS G120 drive systems. It supplies a 7.5 kW low-overload duty or a 5.5 kW high-overload duty from a three-phase 380–480 V line.
The two duty profiles have different input and output current ratings, so selection should follow the motor load cycle rather than power alone. The IP20 module is intended for installation within a suitable enclosure.
Key Functions
Load-profile selection
Low-overload service provides 7.5 kW at 18.0 A, while high-overload service provides 5.5 kW at 13.2 A.
Electrical power conversion
The power module forms the inverter power stage of the modular drive and works with the appropriate control configuration.
Cabinet integration
The unfiltered input and forced-air cooling arrangement allow the installer to coordinate line filtering, branch protection and cabinet airflow.
Official Specifications
| Line supply | 380–480 V, three-phase AC |
|---|---|
| Frame size | FSB |
| Degree of protection | IP20 |
| Low-overload rated power | 7.5 kW |
| High-overload rated power | 5.5 kW |
| Low-overload input current | 22.2 A |
| High-overload input current | 19.8 A |
| Low-overload output current | 18.0 A |
| High-overload output current | 13.2 A |
| Power loss | 0.2 kW |
| Required cooling airflow | 9.2 l/s |
| Module weight without filter | 3.0 kg |
Frequently Asked Questions
Can I select 6SL3210-1PE21-8UL0 for a 7.5 kW motor with a demanding load cycle?
A 7.5 kW selection uses the low-overload rating, while high-overload operation is rated 5.5 kW, so the actual motor duty must determine the selection.
Which output-current limit should I use for high-overload sizing of 6SL3210-1PE21-8UL0?
Use the 13.2 A high-overload base-load output current when sizing that duty profile.
Does 6SL3210-1PE21-8UL0 include an input line filter?
This is the unfiltered variant, so any required external EMC measures must be included in the installation design.
How much airflow should the cabinet provide for 6SL3210-1PE21-8UL0?
The module requires a cooling-air flow of 9.2 l/s.
What heat load should I allow for 6SL3210-1PE21-8UL0?
Allow for the specified 0.2 kW of power loss when calculating cabinet cooling.
Which fuse rating is listed for a UL Class J installation with 6SL3210-1PE21-8UL0?
The frame-size-B selection table gives a 35 A Class J fuse for this power module.
What input current should I budget for low-overload operation of 6SL3210-1PE21-8UL0?
The low-overload base-load input current is 22.2 A.