Overview
SINAMICS G120

6SL3210-1PE12-3UL1 SINAMICS PM240-2 Power Module

Frame FSA power module for 380–480 V three-phase supplies, rated 0.75 kW at low overload or 0.55 kW at high overload.

At a Glance

Brand Siemens
Model 6SL3210-1PE12-3UL1
Product Type Drive power module
Core Function Variable-frequency motor power conversion
Application SINAMICS G120 modular drive systems

Two overload duty profiles

Low-overload operation provides 0.75 kW, while high-overload operation provides 0.55 kW with a higher short-term overload allowance.

Variable motor frequency

The power module supports output frequency ranges up to 200 Hz in vector operation and 550 Hz in V/f operation.

Compact FSA integration

The IP20 air-cooled power stage uses plug-in screw terminals for line and motor connections.

Product Overview

6SL3210-1PE12-3UL1 forms the power stage of a modular SINAMICS G120 drive, converting a three-phase 380–480 V input into a variable-frequency motor output.

Its low-overload and high-overload ratings suit different load profiles, while a compact FSA housing and air cooling allow integration with the selected drive control unit.

Ordering focus: Size the drive for either the 0.75 kW low-overload duty or the 0.55 kW high-overload duty, including the corresponding current and ambient-temperature limits.
Key Functions

Two overload duty profiles

Low-overload operation provides 0.75 kW, while high-overload operation provides 0.55 kW with a higher short-term overload allowance.

Variable motor frequency

The power module supports output frequency ranges up to 200 Hz in vector operation and 550 Hz in V/f operation.

Compact FSA integration

The IP20 air-cooled power stage uses plug-in screw terminals for line and motor connections.

Official Specifications
Input voltage and frequency 3 AC 380–480 V ±10%; 47–63 Hz
Rated input current 2.90 A low overload; 2.60 A high overload
Rated output power 0.75 kW low overload; 0.55 kW high overload
Rated output current 2.20 A low overload; 1.70 A high overload
Maximum output current 3.40 A
Pulse frequency 4 kHz
Output frequency ranges 0–200 Hz vector; 0–550 Hz V/f
Low-overload cycle 110% for 57 s and 150% for 3 s per 300 s
High-overload cycle 150% for 57 s and 200% for 3 s per 300 s
Efficiency and power loss 96%; 0.04 kW
Power factors λ = 0.85; cos φ = 0.95
Cooling airflow 0.005 m³/s
Operating ambient −10 to +40°C low overload; −10 to +50°C high overload
Maximum installation altitude 1000 m
Relative humidity 95% maximum, without condensation
Power-terminal conductor range 1–2.5 mm², AWG 18–14
Motor cable length 50 m shielded; 100 m unshielded
Enclosure and frame IP20 / UL open type; FSA
Dimensions and mass 73 × 196 × 165 mm (W × H × D); 1.40 kg
Acoustic pressure 72 dB at 1 m
Frequently Asked Questions

Should I choose the low-overload or high-overload rating of 6SL3210-1PE12-3UL1?

Select the duty from the motor load profile, using 0.75 kW and 2.20 A for low overload or 0.55 kW and 1.70 A for high overload.

Can 6SL3210-1PE12-3UL1 operate from a single-phase supply?

The power module requires a three-phase 380–480 V supply within ±10% of the rated voltage.

How does the permitted ambient temperature change with duty on 6SL3210-1PE12-3UL1?

The operating range is −10 to +40°C at low overload and −10 to +50°C at high overload.

What frequency ceiling applies when 6SL3210-1PE12-3UL1 runs vector control?

Vector operation extends to 200 Hz, while the V/f output range extends to 550 Hz.

How long may the motor cable connected to 6SL3210-1PE12-3UL1 be?

The cable limit is 50 m with shielding or 100 m without shielding.

Does 6SL3210-1PE12-3UL1 provide a closed enclosure for exposed installation?

The power stage has IP20 protection and UL open-type construction, so the installation must provide the required enclosure protection.

What overload can 6SL3210-1PE12-3UL1 deliver for a high-overload start?

High-overload duty permits 200% output current for 3 s and 150% for 57 s in a 300 s cycle.

Compatibility & Ordering Notes
Before ordering 6SL3210-1PE12-3UL1: Size the drive for either the 0.75 kW low-overload duty or the 0.55 kW high-overload duty, including the corresponding current and ambient-temperature limits.

Before installation

  • Select the compatible SINAMICS G120 control unit and configure the drive for the intended motor and duty profile.
  • Provide the required air path for the 0.005 m³/s cooling airflow.
  • Keep motor wiring within the 50 m shielded or 100 m unshielded cable limit.
  • Use the FSA dimensions and IP20 construction when planning enclosure space and protection.
Hot Selling Models
6NH1804-0AA01-2BB2
ZB8610
OGT500 OGT-FPKG/US100
MHZ2 10DN
CAN/MM100
7000-P4141-P070500
3SE5162-0CE01
3SU1803-0AA00-0AB1
16/C2MBD-PAC 2700676
ABB S204-B6 2CDS 254 001 R0065
QU-NH000
BE 2817741
3C16610 1661-010-000-8.00
Quint-PS/1AC/24DC/3.5
TI-505 5054716

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.